The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Outdoor-indoor air pollution in urban environment: challenges and opportunity
Open accessAbstract
With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics of Air Pollution
Seinfeld, J. H. (1986) · Cited by 1,907
Atmospheric chemistry and physics of air pollution
Barker, J. R. (1987) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(87)90252-3 · Cited by 1,482
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Contribution from indoor sources to particle number and mass concentrations in residential houses
HE, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.027 · Cited by 585
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Relative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Meadow, J. F., Altrichter, A. E., Kembel, S. W., Kline, J., Mhuireach, G., Moriyama, M., Northcutt, D., O'Connor, T. K., Womack, A. M., Brown, G. Z., et al. (2014) · Indoor Air · doi:10.1111/ina.12047 · Cited by 411
Jones, N. C., Thornton, C. A., Mark, D., & Harrison, R. M. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00489-6 · Cited by 374
Indoor ozone/terpene reactions as a source of indoor particles
Weschler, C. J., & Shields, H. C. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00083-7 · Cited by 319
Relationship between outdoor and indoor air quality in eight French schools
Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00263.x · Cited by 317
Baek, S.-O., Kim, Y.-S., & Perry, R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00215-4 · Cited by 298
Indoor–outdoor relationships of respirable sulfates and particles
Dockery, D. W., & Spengler, J. D. (1981) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(81)90036-6 · Cited by 273
An investigation of urban heat island intensity (UHII) as an indicator of urban heating
Memon, R. A., Leung, D. Y. C., & Liu, C.-H. (2009) · Atmospheric Research · doi:10.1016/j.atmosres.2009.07.006 · Cited by 259
Self-citationWallace, L. A., Pellizzari, E. D., D.Hartwell, T., Sparacino, C. M., Sheldon, L. S., & Zelon, H. (1985) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(85)90217-3 · Cited by 185
Indoor–outdoor relationships of particle number and mass in four European cities
Hoek, G., Kos, G., Harrison, R., de Hartog, J., Meliefste, K., ten Brink, H., Katsouyanni, K., Karakatsani, A., Lianou, M., & Kotronarou, A. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.09.026 · Cited by 180
Monn, C., Fuchs, A., Högger, D., Junker, M., Kogelschatz, D., Roth, N., & Wanner, H.-U. (1997) · Science of The Total Environment · doi:10.1016/s0048-9697(97)00271-4 · Cited by 174
Estimating the concentration of indoor particles of outdoor origin: A review
Diapouli, E., Chaloulakou, A., & Koutrakis, P. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.791649 · Cited by 173
Massey, D., Masih, J., Kulshrestha, A., Habil, M., & Taneja, A. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.010 · Cited by 167
K. Koponen, I., Asmi, A., Keronen, P., Puhto, K., & Kulmala, M. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00338-1 · Cited by 162
LIU, W., ZHANG, J., ZHANG, L., TURPIN, B., WEISEL, C., MORANDI, M., STOCK, T., COLOME, S., & KORN, L. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.12.005 · Cited by 160
Lee, T., Grinshpun, S. A., Martuzevičius, D., Adhikari, A., Crawford, C. M., Luo, J., & Reponen, T. A. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00396.x · Cited by 159
Exploring the consequences of climate change for indoor air quality
Nazaroff, W. W. (2013) · Environmental Research Letters · doi:10.1088/1748-9326/8/1/015022 · Cited by 150
Indoor and outdoor PM mass and number concentrations at schools in the Athens area
Diapouli, E., Chaloulakou, A., Mihalopoulos, N., & Spyrellis, N. (2007) · Environmental Monitoring and Assessment · doi:10.1007/s10661-007-9724-0 · Cited by 149
Cyrys, J., Pitz, M., Bischof, W., Wichmann, H. ‐., & Heinrich, J. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500317 · Cited by 149
Pekey, B., Bozkurt, Z., Pekey, H., Doğan, G., Zararsız, A., Efe, N., & Tuncel, G. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00628.x · Cited by 143
Airborne Fungal Colony-Forming Units in Outdoor and Indoor Environments in Yokohama, Japan
Takahashi, T. (1997) · Mycopathologia · doi:10.1023/a:1006831111595 · Cited by 137
Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure
Adgate, J. L., Ramachandran, G., Pratt, G. C., Waller, L. A., & Sexton, K. R. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00326-6 · Cited by 119
Cheng, W., Liu, C., & Leung, D. Y. C. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.04.054 · Cited by 112
Self-citationChan, A. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00471-x · Cited by 106
Cao, J., Lee, S., Chow, J. C., Cheng, Y., Ho, K., Fung, K., Liu, S. X., & Watson, J. G. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00336.x · Cited by 102
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Meng, Q. Y., Turpin, B. J., Lee, J., Polidori, A., Weisel, C. P., Morandi, M. T., Colome, S. D., Zhang, J. J., Stock, T. H., & Winer, A. (2007) · Environmental Science & Technology · doi:10.1021/es070037k · Cited by 75
An evaluation of indoor and outdoor biological particulate matter
Menetrez, M. Y., Foarde, K. K., Esch, R. K., Schwartz, T. D., Dean, T. R., Hays, M. D., Cho, S., Betancourt, D. A., & Moore, S. A. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.07.027 · Cited by 69
Johnson, T., Myers, J. D., Kelly, T. J., Wisbith, A. S., & Ollison, W. M. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500294 · Cited by 63
Modeling Relationships between Indoor and Outdoor Air Quality
Freijer, J. I., & Bloemen, H. J. T. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464007 · Cited by 60
Climate change, the indoor environment, and health
(2012) · Choice Reviews Online · doi:10.5860/choice.49-3292 · Cited by 49
Garrett, M., Hooper, B. M., Cole, F. M., & Hooper, M. A. (1997) · Aerobiologia · doi:10.1007/bf02694428 · Cited by 47
Cited by
Tran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Direct human health risks of increased atmospheric carbon dioxide
Jacobson, T. A., Kler, J. S., Hernke, M. T., Braun, R. K., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 609
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
Singh, N., Singh, S., & Mall, R. K. (2020) · Urban Ecology · doi:10.1016/b978-0-12-820730-7.00017-3 · Cited by 211
Global environmental change and noncommunicable disease risks
Frumkin, H., & Haines, A. (2019) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-040218-043706 · Cited by 194
Metadata
- Authors
- Leung, D. Y. C.
- Venue
- Frontiers in Environmental Science
- Publisher
- Frontiers Media SA
- Published
- 2015-01-15
- Volume
- 2
- ISSN
- 2296-665X (ISSN-L)
- OpenAlex
- W2031725149
- Cited by
- 401
- References
- 39
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.