Validating Measures of Electrodermal Activity and Heart Rate Variability Derived From the Empatica E4 Utilized in Research Settings That Involve Interactive Dyadic States
Open accessAbstract
Portable and wireless devices that collect physiological data are becoming more and more sought after in clinical and psychophysiological research as technology swiftly advances. These devices allow for data collection in interactive states, such as dyadic therapy, with reduced restraints compared to traditional laboratory devices. One such portable device is the Empatica E4 wristband (Empatica Srl, Milan, Italy) which allows quantifying cardiac interbeat intervals (IBIs), heart rate variability (HRV), and electro-dermal activity (EDA), as well as several other acceleration and temperature measures. In the current study, we aimed to assess IBI, HRV, and EDA measures, against the same data collected from the well-validated MindWare mobile impedance cardiograph device (MindWare Technology, Gahanna, OH, United States). We assessed the E4 strictly as a research instrument and not as a clinical tool. We were specifically interested in the wristbands' performance during naturalistic interactive face-to-face conversations which inherently involve more hand movements. We collected data from 30 participants, nested in 15 dyads, which were connected to both devices simultaneously, during rest and during a social conversation. After preprocessing and analyses, we found that mean IBIs obtained by the E4 and the MindWare device, were highly similar during rest and during conversation. Medium to high correlations were found between the devices with respect to several HRV measures, with higher correlations during rest compared to conversation. The E4 failed to produce reliable EDA data. We conclude by discussing the strengths and limitations of the E4 during seated conversational states and suggest optimal ways to collect and analyze data with the E4.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While a complete loss of contact results in a 0-line for the EDA signal, motion artifacts without contact loss result in abrupt level changes or high amplitude fluctuations, and PPG shows considerable deviation from expected signal patterns24,42.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Shaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866 · cited 2×
“As measuring HRV does not require particularly invasive testing, it is extensively acquired in psychological science and is considered a reliable estimate of autonomic nervous system modulation, via the vagus nerve, of sinus node cardiac activity (Blascovich et al., 2011; Kaufmann et al., 2011; Shaffer et al., 2014).”
BackgroundThe polyvagal theory: phylogenetic substrates of a social nervous system.
Porges, S. W. (2001) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(01)00162-3 · Cited by 1,582 · cited 1×
“…conversational states beyond the stress response, as they involve different and perhaps more subtle regulatory capacities of the autonomic nervous system (Porges, 2001), which are of specific interest to many researchers aiming to understand the mechanism underlying changes in HRV and EDA measures.”
BackgroundSome signals and rules for taking speaking turns in conversations.
Duncan, S. (1972) · Journal of Personality and Social Psychology · doi:10.1037/h0033031 · Cited by 1,386 · cited 1×
“A final reason to include a conversation paradigm is the fact that more movement related artifacts occur during speaking, due to gesturing (Duncan, 1972).”
BackgroundMalík, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 1,031 · cited 2×
“SDNN, which is a measure of general variability, HF, which represents cardiovagal activity (Camm et al., 1996) and IBI include both parasympathetic and sympathetic influences (Berntson et al.”
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998 · cited 1×
“This frequency band in particular has been shown to represent parasympathetic nervous system regulation almost exclusively, and thus is a highly sought after (Berntson et al., 1993).”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 8×
“We imported the raw data obtained from the E4 wristband into Kubios, after it was organized to fit Kubios’ specifications with MATLAB 2018a. Kubios HRV Premium software includes an adaptive QRS detection algorithm, pulse wave detectors and tools for automatic and threshold based artifact correction, trend removal and…”
MethodInfluential
Research works printed but not linked: 7
- 2015, Issues with EDA Values.
- 2017, Comparison Procomp Vs Empatica E3 Skin Conductance Signal.
- 2018, Session Start-Time Format and Synchronization.
- 2019, Support Page.
- Kamath, 2012, Heart rate variability (HRV) signal analysis: Clinical applications. Heart Rate Variability (HRV) Signal Analysis: Clinical Applications.
- 2013, R: A Language and Environment for Statistical Computing.
- Tarvainen, 2019, Kubios HRV User’s Guide
Cited by
Sorted by citations
Items 101–180 of 180
Lory, C., Rispoli, M. J., Keehn, B., Mason, R. A., Mason, B. A., Kang, S., Borosh, A. M., Shannon, E. N., & Crosley, H. C. (2023) · Advances in Neurodevelopmental Disorders · doi:10.1007/s41252-023-00317-6 · Cited by 4
“Recent research that investigated the validity of the E4 wristband in measuring heart rate suggests that HRV data obtained from the E4 wristband is comparable to the gold standard electrocardiogram device (Milstein & Gordon, 2020; Stuyck et al., 2022).”
MethodJohansen, A. O., Mølgaard, J., Rasmussen, S. M., Gu, Y., Grønbæk, K. K., Sørensen, H. B. D., Aasvang, E. K., & Meyhoff, C. S. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01030-4 · Cited by 5
“We used wireless Empatica E4 wristbands in our study to monitor EDA, and a study found that the Empatica E4 produced unreliable EDA data when this device was compared to the MindWare device [24].”
MethodHolistic quantified-self for context-aware wearable augmented reality
Song, E., Ha, T., Park, J., Lee, H., & Woo, W. (2025) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2025.103568 · Cited by 4
Bidirectional Human–Drone Safety Communication in Construction
Zhu, Z., Jeelani, I., & Gheisari, M. (2025) · Journal of Construction Engineering and Management · doi:10.1061/jcemd4.coeng-17106 · Cited by 3
Bulagang, A. F., Mountstephens, J., & Teo, J. (2021) · IEEE International Conference on Computing (ICOCO) · doi:10.1109/icoco53166.2021.9673506 · Cited by 3
EmotiphAI: a biocybernetic engine for real-time biosignals acquisition in a collective setting
Bota, P. J., Fléty, E., Silva, H., & Fred, A. L. N. (2022) · Neural Computing and Applications · doi:10.1007/s00521-022-07191-8 · Cited by 3
“In [10], the authors compare the Empatica E4 wrist-band data, namely EDA, cardiac interbeat intervals (IBIs), and heart rate variability (HRV) against a validated MindWare mobile impedance cardiograph device 2 by measuring the correlation between the signals from the two devices.”
MethodThomassin, K., Neufeld, S. M., Ansari, N., & Vogel, N. (2023) · Sensors · doi:10.3390/s23239470 · Cited by 3
“The Empatica E4 wristband is a validated tool for collecting EDA in both adult and youth samples [16–18 , 24 ].”
MethodDesign Thinking the Human-AI Experience of Neurotechnology for Knowledge Workers
Weekes, T. R., & Eskridge, T. C. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-17618-0_37 · Cited by 3
Detecting Burnout of Health Care Professionals in a COVID-19 Testing Laboratory
Leite, C. C. M., Chronopoulou, A., Yuceel, A. I., & Wooldridge, A. R. (2022) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181322661066 · Cited by 1
“The software has a proprietary algorithm that removes ectopic heartbeats and extracts the intra-beat intervals (IBI) from the BVP data (Milstein & Gordon, 2020).”
MethodCano, S. P., Franco, E., Apablaza, J., & García, M. J. (2023) · Preprints.org · doi:10.20944/preprints202308.1236.v1 · Cited by 2
van Swieten, M., de Looff, P. C., VanDerNagel, J., Bouwmeester, S., & Didden, R. (2025) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2025.104976 · Cited by 2
Yorke, I., Boatman, C. A., Choudhury, A. R., Oakley, B. F. M., Conde, P., Sankesara, H., Ranjan, Y., Rashid, Z., Dineley, J., Downs, J. M., et al. (2025) · JMIR Research Protocols · doi:10.2196/71145 · Cited by 3
“Cameras and a lapel microphone are set up before the participant enters the room (as depicted in Figure S2 in Multimedia Appendix 1 [27,28,49,57-75]).”
Amaro, J., Ramusga, R., Bonifácio, A., Almeida, A., Frazão, J., Cruz, B. F., Erskine, A., Carvalho, F., Lopes, G., Chokhachian, A., et al. (2025) · Sensors · doi:10.3390/s25237163 · Cited by 3
Wearanize+ : a multimodal dataset for evaluating wearable technologies in sleep research
Sikder, N., Verkaar, L., Paltarzhytskaya, A., Acan, S., Bovy, L., Almazova, T., Krugliakova, E., Rosenblum, Y., Krauledat, M., Dresler, M., et al. (2025) · SLEEP Advances · doi:10.1093/sleepadvances/zpaf094 · Cited by 2
“Due to its portability and ability to continuously collect high-quality biometric data,it has been extensively used in numerous research studies, including stress detection [64] and monitoring [65], estimation of HR V [66, 67], and measurement of EDA [68] and cardiac activity [69].”
Chhangur, R. R., & Belsky, J. (2023) · PLoS ONE · doi:10.1371/journal.pone.0282207 · Cited by 2
“Movement with the Empatica E4 will be sampled at a frequency of 32 Hz (and has a resolution of 8 bits) with a sensor that measures acceleration in space over time on an x, y, and z-axis [39].”
A Physiological Approach of Presence and VR Sickness in Simulated Teleoperated Social Tasks
Achanccaray, D., & Sumioka, H. (2023) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53992.2023.10394241 · Cited by 2
“Some studies analyzed SCR and heart rate reliability and concluded that measures for a short time (less than 5 minutes) are reliable [33]–[35].”
BackgroundPirinen, V., Eggers, K., Dindar, K., Helminen, T. M., Kotila, A., Kuusikko‐Gauffin, S., Mäkinen, L., Ebeling, H. E., Hurtig, T. M., Mäntymaa, M., et al. (2024) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2024.106425 · Cited by 3
Advanced Energy-Efficient System for Precision Electrodermal Activity Monitoring in Stress Detection
Zhang, R., Fang, R., Hosseini, E., Fang, C., Miao, N., & Homayoun, H. (2024) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn63547.2024.10780551 · Cited by 2
“Moreover, a Pearson Correlation coefficient of 0.73, calculated from data collected simultaneously from both hands, confirms the robustness of our system in accurately capturing dynamic EDA signals in real-time [19].”
MethodInfluentialUsing Multimodal Data to Predict Surgeon Situation Awareness
Léchappé, A., Chollet, M., Rigaud, J., & Cao, C. G. L. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-74614-8_37 · Cited by 2
Characterizing player responses to surprising events in 2D platform games
Chakraborttii, C., & Osborne, A. (2022) · Entertainment Computing · doi:10.1016/j.entcom.2022.100542 · Cited by 2
Feasibility of wearable sensors in the NICU: Psychophysiological measures of parental stress
Duker, L. I. S., Kwon, J., Richter, M., & Pineda, R. G. (2023) · Early Human Development · doi:10.1016/j.earlhumdev.2023.105814 · Cited by 2
Propagation of the Measurement Uncertainty of Wearable Sensors for Thermal Comfort Assessment
Cosoli, G., Mansi, S. A., Revel, G. M., & Arnesano, M. (2023) · IEEE International Workshop on Metrology for Living Environment (MetroLivEnv) · doi:10.1109/metrolivenv56897.2023.10164004 · Cited by 2
“Furthermore, many studies evaluate the strength of the linear correlation with the reference sensors, computing the Pearson’s correlation coefficient [27]; however, a strong correlation does not necessarily mean a good agreement [28].”
BackgroundBérubé, C., Maritsch, M., Lehmann, V. F., Kraus, M., Feuerriegel, S., Züger, T., Wortmann, F., Stettler, C., Fleisch, E., Kocaballi, A. B., et al. (2024) · JMIR Human Factors · doi:10.2196/46967 · Cited by 3
Miyamoto, K., Tanaka, H., Shidara, K., & Nakamura, S. (2023) · International Conference on Speech Database and Assessments · doi:10.1109/o-cocosda60357.2023.10482975 · Cited by 2
“Some previous studies address the use of ECG to predict emotions [19], [20].”
Zaks, I., Dekel, R., Shoval‐Zuckerman, Y., & Horesh, D. (2023) · Contemporary Clinical Trials · doi:10.1016/j.cct.2023.107280 · Cited by 1
Gao, B., Niu, S., Zhang, X., Sun, X., & Ren, X. (2023) · International Association of Societies of Design Research Congress (IASDR) · doi:10.21606/iasdr.2023.416 · Cited by 1
“E4 wristband was chosen for two reasons: firstly, it is portable that can be easily deployed outside, as well as non-invasive and light weighted, which means that it has a minimal impact on participants (Milstein & Gordon, 2020); secondly, it is medically certificated.”
Mittermeier, S., Gregorová, K., Göttfert, C., Merz, C., Weiss, M. H., Krauss, J., Franke, S., Reiter, A. M. F., Wienrich, C., & Buerger, A. (2025) · International Journal of Clinical and Health Psychology · doi:10.1016/j.ijchp.2025.100583 · Cited by 1
“The Empatica E4 software provided the average HR in spans of 10 s, extracted from the blood volume pulse (BVP) signal with a sampling rate of 1 Hz (Milstein & Gordon, 2020).”
InfluentialEvaluating In-situ Cognitive Load Using Physiological Data
Fujii, H., Vargo, A. W., Iwata, M., & Kise, K. (2025) · Augmented Humans International Conference (AHs) · doi:10.1145/3745900.3746119 · Cited by 1
Wagenblast, F., Seibt, R., Rieger, M. A., & Steinhilber, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-28090-7 · Cited by 1
“However, in comparison to measurements of the heart rhythm, EDA is less often assessed in field studies due to several limitations regarding possible influences by physical activity, time of day, or climate, among others 11,28,29 .”
Albayrak-Kutlay, Y., Bengisu, M., & Ergül, E. (2026) · Architecture · doi:10.3390/architecture6010006 · Cited by 1
“…Hz for actigraphy, Empatica Srl, Milan, Italy) whose raw modalities are documented for research use [50] and supported by independent studies benchmarking Empatica wrist-worn autonomic sensing against reference systems and comparable research devices under controlled/low-motion conditions [51,52].”
Sullivan, E. K., Fahmie, T. A., & Gehringer, J. E. (2026) · Journal of Applied Behavior Analysis · doi:10.1002/jaba.70050 · Cited by 1
“…depicted are the consecutive samples collected for Therapist 2 during each functional analysis session. μ S = microsiemens. naturalistic settings (Milstein & Gordon, 2020), processing these data samples using artifact recognition, as was done in this study, may improve precision and overall…”
Houzangbe, S., Lemay, M., & Levac, D. E. (2026) · Virtual Reality · doi:10.1007/s10055-026-01325-2 · Cited by 1
“These studies con - cluded that HR wearables monitors could be useful for research purposes, even during physical activity (Bent et al. 2020 ; Milstein and Gordon 2020 ; Nelson et al. 2020 ).”
Walters, K. F., Templeton, J. M., van Loveren, H., Yusuf, F. R., & Schilaty, N. D. (2026) · Trials · doi:10.1186/s13063-026-09531-8 · Cited by 1
Rho, G., Carbonaro, N., Laurino, M., Tognetti, A., & Greco, A. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110531 · Cited by 1
Verbe, J., Gautier, R. H., Latinus, M., Bonnet‐Brilhault, F., & Briend, F. (2026) · Human Nature · doi:10.1007/s12110-026-09526-z · Cited by 1
“The wristband is a wearable, non-invasive, research device (Milstein and Gordon 2020), which allows for real-time physiological data collection such as blood volume pulse, measured using a photoplethysmogram sensor and from which Heart Rate (HR) (HR = 60/Interbeat Interval, obtained by blood volume…”
Brandebusemeyer, C., Georgi, F., & Bert Arnrich, A. (2026) · Sensors · doi:10.3390/s26144376 · Cited by 3
“Milstein and Gordon [20] assessed the Empatica E4 wristband as a tool for measuring cardiac interbeat intervals (IBIs), heart rate variability (HRV), and EDA, comparing it to the well-validated MindWare mobile impedance cardiograph.”
Zhang, X., & Du, J. (2026) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2026.103171 · Cited by 1
Huang, L. C., Akbari, A., & Jafari, R. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639812 · Cited by 1
“One study has shown medium-high (0.74 - 0.88) correlation between wrist-worn PPG sensors and ECG in HRV parameters at rest condition, but the correlation was lower (0.42 - 0.67) while subjects were talking [16].”
BackgroundInfluentialIntegrative Sensing Techniques for Building Non-Invasive Body Sensor Networks
Ko, C., & Oteafy, S. (2023) · International Conference on Communications · doi:10.1109/icc45041.2023.10279753 · Cited by 1
Khorshid, S., Song, S., Chen, K., & Lyu, P. (2024) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/9780784485248.073 · Cited by 1
The Mobile Phone Electromagnetic Radiation Effects on Heart Rate Variability Function
Ubed, H., Memon, I., Mangi, F. A., Razaq, M., Rahat, A., & Ahmed, Z. (2024) · Journal of Health and Rehabilitation Research · doi:10.61919/jhrr.v4i1.661 · Cited by 1
TrueWatch: Polygraph Examination With Smartwatches
Alper, R., & Guri, M. (2024) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2024.3435409 · Cited by 1
“Milstein and Gordon [33] recommend Empatica E4 for IBIs and HRV research, but not for studies that require EDA indicators.”
BackgroundUsing a Smartwatch to Evaluate Subjective Ratings of Driving Functions
Panzer, A., Lausch, H., Iatropoulos, J., & Henze, R. (2024) · Lecture notes in mechanical engineering · doi:10.1007/978-3-031-70392-8_62 · Cited by 1
López, A. M. R., Caro, M. R., Patalas, D., & Jasielska, A. (2025) · Research methods in applied linguistics · doi:10.1075/rmal.10.11roj · Cited by 1
Hindash, A. C., Altman, A. D., Levitan, J. A., & Inslicht, S. S. (2022) · American Journal of Psychotherapy · doi:10.1176/appi.psychotherapy.20210044 · Cited by 2
Cognitive load dissonance and personality factors: an empirical analysis in organizational settingsPreprint
Gruttola, F. D., Antonio, M., Orfei, M. D., D’Arcangelo, S., Lattanzi, N., Ricciardi, E., & Malizia, A. P. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.12.05.570254 · Cited by 1
Sympathetic activation of sensory input and learningPreprint
Flø, E. E., & Flø, G. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.01.722216 · Cited by 1
Francey, A. (2021) · UWSpace (University of Waterloo)
A Transparency Statement Transforms Community-Police InteractionsPreprint
Yeager, D. S., Dobson, K. S. H., & Dittmann, A. G. (2022) · Research Square · doi:10.21203/rs.3.rs-1726104/v1
Characterizing Surprising Reactions of Players in 2d Platform GamesPreprint
Chakraborttii, C., & Kolesnichenko, A. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4111788
Lee, V. R. (2023) · Advances in analytics for learning and teaching · doi:10.1007/978-3-031-30992-2_13
Psychophysiology in the digital age
van der Mee, D. J. (2023) · doi:10.5463/thesis.258
Challenges in Using Skin Conductance Responses for Assessments of Information Worker Productivity
Ahmad, A., & Plötz, T. (2023) · International Symposium on Wearable Computers · doi:10.1145/3594738.3611360
“sured is social interaction in parent-child dyadic groups [12, 21, 37].”
Zhou, Y., Mousavi, A. S., Chalumuri, Y. R., Parreira, J. D., Modak, M., Sanchez-Perez, J. A., Gazi, A., Inan, O. T., & Hahn, J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4591656
Richter-Lunn, K., & y López, J. L. G. D. C. (2021) · ACADIA quarterly · doi:10.52842/conf.acadia.2021.520
(2024) · Tourism social science series · doi:10.1108/s1571-504320240000027032
Rho, G., Carbonaro, N., Laurino, M., Tognetti, A., & Greco, A. (2024) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine62247.2024.10796284
“Wrist devices can provide accurate HR estimates during resting activities [2], [3].”
Moharana, B., Keighrey, C., & Murray, N. (2024) · International Conference on Virtual Reality · doi:10.1109/icvr62393.2024.10868723
Landman, W., Rijckmans, M. J. N., Spreen, M., de Looff, P. C., van Meurs, L., & Bogaerts, S. (2025) · Sexual Health & Compulsivity · doi:10.1080/10720162.2025.2552126
“HRV measurements are most reliable in non-movement or very low movement and resting condition (Milstein & Gordon, 2020; Schuurmans et al., 2020).”
Psychophysiological Computational Modeling for Stress Management in VR Driving Simulation
Ram, A. S. R., Li, Y. J., Islam, M. M., & He, S. (2025) · International Conference on Virtual Reality · doi:10.1109/icvr66534.2025.11172566
“The reliability of wearable devices, particularly the Em-patica E4, was validated by Milstein and Gordon [7], who confirmed their robustness in interactive scenarios.”
Durmaz, A., & Bakı, B. M. (2025) · Medical Technologies Congress (TIPTEKNO) · doi:10.1109/tiptekno68206.2025.11270187
Tran, A. Q., Tran, D., Nguyen, M. G., & Dang, T. H. (2025) · IEEE International Conference on Machine Learning and Applied Network Technologies (ICMLANT) · doi:10.1109/icmlant68509.2025.11394852
“…E4) provide high accuracy but are expensive and require proprietary software, restricting their use in education and low-resource laboratories [15]; Noise susceptibility and motion artifacts — EDA signals are highly sensitive to temperature, electrode placement, and movement, leading to…”
Turnamian, M. R., Kleiman, E. M., Burke, T. A., & Liu, R. (2026) · Psychiatry Research · doi:10.1016/j.psychres.2026.117048
Alghoul, K., Mohd, F., Laamarti, F., Osman, H. A., & Saddik, A. E. (2026) · ACM Transactions on Multimedia Computing Communications and Applications · doi:10.1145/3836767
“The E4 is widely used in affective computing and clinical research [18] due to its high signal fidelity and unobtrusive design [25].”
Chhangur, R. R., Pupillo, F., & Belsky, J. (2026) · Child Development · doi:10.1093/chidev/aacag095
Delgado-Terán, J. D., Wezel, R. J. A. V., & Heida, T. (2026) · European Journal of Neuroscience · doi:10.1111/ejn.70551
“Study parameters to answer the study's main endpoint in the semi- free-living condition were collected using a smartwatch (Empatica E4), which had been previously validated for ambulatory electrodermal activity measurements (Hu et al. 2024; Milstein and Gordon 2020).”
van Reekum, P., van den Boogert, F., de Looff, P. C., Veling, W., Jacobi, C., van de Griend, L., Bogaerts, S., & Masthoff, E. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1792178
“Wrist-worn devices are known to suffer from loose connections, poor electrode placement or movement artifacts, among other elements, and may not have been optimal for capturing physiological signals during VR sessions (Milstein and Gordon, 2020; Schuurmans et al., 2020).”
Fogarty, J. S., Yifan, W., Yuvaraj, R., Ali, F., & Hoe, L. N. (2026) · Trends in Neuroscience and Education · doi:10.1016/j.tine.2026.100291
Moharana, B., Keighrey, C., & Murray, N. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-30816-0_8
Machine learning-based automatic stress detection: Performance and generalization across datasets
Calza-Metre, M., & Borzì, L. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100693
Fernández-Matellán, R., Puertas-Ramirez, D., Martín, D., & Boticario, J. G. (2026) · Sensors · doi:10.3390/s26144529
“…a research-grade wearable device commonly used in ambulatory settings to record blood volume pulse (BVP), electrodermal activity (EDA), skin temperature (TEMP), and triaxial acceleration, together with heart rate (HR) estimates derived from the photoplethysmography (PPG)-based BVP signal [19,20].”
Thapa, S., & Sarkar, A. (2026) · IEEE Intelligent Vehicles Symposium · doi:10.1109/iv66570.2026.11623989
McNaboe, R. Q., Díaz, L. R. M., Faremi, B. E., & Posada-Quintero, H. F. (2026) · Signals · doi:10.3390/signals7040073
Xu, R., Cao, S., Barnett‐Cowan, M., Bülbül, G. B., Kearns, S. K., & Niechwiej‐Szwedo, E. (2026) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2026.1911259
“…rows, and treat the frontal band powers as the device-level estimates that comparable consumer-EEG studies have validated (Krigolson et al., 2017; Cannard et al., 2021; Milstein and Gordon, 2020); dry frontal electrodes in a moving cockpit may nonetheless retain some non-neural contribution.”
Jiang, W., Mao, J., Quan, Z., Zhao, J., Xu, D., Long, Y., & Song, X. (2026) · Applied Spatial Analysis and Policy · doi:10.1007/s12061-026-09999-6
“Empatica E4 is easy to operate and has been applied in many studies (Campanella et al., 2023; Milstein & Gordon, 2020).”
Baquerizo-Sedano, M., Pedrazo, M. L., Martínez, M. M., Taype-Rondán, Á., Gómez, J. L. C., & Manzanares, M. C. S. (2026) · Healthcare · doi:10.3390/healthcare14182990
Valenzuela‐Pascual, C., Garriga, M., Borràs, R., Voltà-Solerdelcoll, R., Korniyenko, M., Mas, A., Escala, C., de Looff, P. C., Anmella, G., Benabarre, A., et al. (2026) · JMIR Mental Health · doi:10.2196/94737
“Wearable technologies enable continuous and real-world monitoring of digital biosignals such as electrodermal activity (EDA) and heart rate (HR), which have been proposed as potential digital biomarkers [5, 6].”
Haim, A., Thirion, A., Mulliez, B., Zhou, Y., Hahn, J. O., & Tap, H. (2026) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc66907.2026.11694399
Em, P. P., & Teoh, T. S. (2026) · Sensors · doi:10.3390/s26196202
“The Empatica E4 wristband, which shares sensor hardware with the newer EmbracePlus, has been validated against research-grade equipment for electrodermal activity [69–71], cardiac and electrodermal measures jointly [72], and EDA/HRV in interactive settings [73].”
Next‐Generation Brain Health Monitoring Enabled by Integrated Wearable AI Infrastructure
Masrur, M. A., Khan, B., Khalid, R. T., Sumaira, & Abdullah, S. (2026) · Smart Medicine · doi:10.1002/smmd.70053
Metadata
- Authors
- Milstein, N., & Gordon, I.
- Affiliations
- Bar-Ilan University (IL)
- Corresponding author
- Gordon, Ilanit
- Venue
- Frontiers in Behavioral Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2020-08-18
- Volume
- 14
- Pages
- 148-148
- ISSN
- 1662-5153 (ISSN-L)
- OpenAlex
- W3058974884
- Cited by
- 180
- References
- 43
- Citations by year
- 2026: 28 · 2025: 29 · 2024: 32 · 2023: 44 · 2022: 29 · 2021: 17 · 2020: 1
- FWCI
- 14.08
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Behavioral Neuroscience (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Israel Science Foundation
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- Empatica E4, electrodermal activity, heart rate variability, RR interval, device validation, dyadic therapy, face-to-face communication, naturalistic interaction, psychophysiological measurement, measurement reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review