Validating Measures of Electrodermal Activity and Heart Rate Variability Derived From the Empatica E4 Utilized in Research Settings That Involve Interactive Dyadic States
Open accessAbstract
Portable and wireless devices that collect physiological data are becoming more and more sought after in clinical and psychophysiological research as technology swiftly advances. These devices allow for data collection in interactive states, such as dyadic therapy, with reduced restraints compared to traditional laboratory devices. One such portable device is the Empatica E4 wristband (Empatica Srl, Milan, Italy) which allows quantifying cardiac interbeat intervals (IBIs), heart rate variability (HRV), and electro-dermal activity (EDA), as well as several other acceleration and temperature measures. In the current study, we aimed to assess IBI, HRV, and EDA measures, against the same data collected from the well-validated MindWare mobile impedance cardiograph device (MindWare Technology, Gahanna, OH, United States). We assessed the E4 strictly as a research instrument and not as a clinical tool. We were specifically interested in the wristbands' performance during naturalistic interactive face-to-face conversations which inherently involve more hand movements. We collected data from 30 participants, nested in 15 dyads, which were connected to both devices simultaneously, during rest and during a social conversation. After preprocessing and analyses, we found that mean IBIs obtained by the E4 and the MindWare device, were highly similar during rest and during conversation. Medium to high correlations were found between the devices with respect to several HRV measures, with higher correlations during rest compared to conversation. The E4 failed to produce reliable EDA data. We conclude by discussing the strengths and limitations of the E4 during seated conversational states and suggest optimal ways to collect and analyze data with the E4.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While a complete loss of contact results in a 0-line for the EDA signal, motion artifacts without contact loss result in abrupt level changes or high amplitude fluctuations, and PPG shows considerable deviation from expected signal patterns24,42.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Shaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866 · cited 2×
“As measuring HRV does not require particularly invasive testing, it is extensively acquired in psychological science and is considered a reliable estimate of autonomic nervous system modulation, via the vagus nerve, of sinus node cardiac activity (Blascovich et al., 2011; Kaufmann et al., 2011; Shaffer et al., 2014).”
BackgroundThe polyvagal theory: phylogenetic substrates of a social nervous system.
Porges, S. W. (2001) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(01)00162-3 · Cited by 1,582 · cited 1×
“…conversational states beyond the stress response, as they involve different and perhaps more subtle regulatory capacities of the autonomic nervous system (Porges, 2001), which are of specific interest to many researchers aiming to understand the mechanism underlying changes in HRV and EDA measures.”
BackgroundSome signals and rules for taking speaking turns in conversations.
Duncan, S. (1972) · Journal of Personality and Social Psychology · doi:10.1037/h0033031 · Cited by 1,386 · cited 1×
“A final reason to include a conversation paradigm is the fact that more movement related artifacts occur during speaking, due to gesturing (Duncan, 1972).”
BackgroundMalík, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 1,031 · cited 2×
“SDNN, which is a measure of general variability, HF, which represents cardiovagal activity (Camm et al., 1996) and IBI include both parasympathetic and sympathetic influences (Berntson et al.”
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998 · cited 1×
“This frequency band in particular has been shown to represent parasympathetic nervous system regulation almost exclusively, and thus is a highly sought after (Berntson et al., 1993).”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 8×
“We imported the raw data obtained from the E4 wristband into Kubios, after it was organized to fit Kubios’ specifications with MATLAB 2018a. Kubios HRV Premium software includes an adaptive QRS detection algorithm, pulse wave detectors and tools for automatic and threshold based artifact correction, trend removal and…”
MethodInfluential
Research works printed but not linked: 7
- 2015, Issues with EDA Values.
- 2017, Comparison Procomp Vs Empatica E3 Skin Conductance Signal.
- 2018, Session Start-Time Format and Synchronization.
- 2019, Support Page.
- Kamath, 2012, Heart rate variability (HRV) signal analysis: Clinical applications. Heart Rate Variability (HRV) Signal Analysis: Clinical Applications.
- 2013, R: A Language and Environment for Statistical Computing.
- Tarvainen, 2019, Kubios HRV User’s Guide
Cited by
Sorted by citations
Vos, G., Trinh, K., Sarnyai, Z., & Azghadi, M. R. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105026 · Cited by 200
“In [77], the authors found the Empatica E4 to be suitable for psychotherapy research focused on Inter-Beat Interval (IBI) and specific HRV measures, but failed to produce reliable EDA data and produced missing IBI data, especially when a subject is being more dynamic.”
BackgroundData quality evaluation in wearable monitoring
Böttcher, S., Vieluf, S., Bruno, E., Joseph, B., Epitashvili, N., Biondi, A., Zabler, N., Glasstetter, M., Dümpelmann, M., Van Laerhoven, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-25949-x · Cited by 91
Magaña, V. C., Scherz, W. D., Seepold, R., Madrid, N. M., Pañeda, X. G., & García, R. (2020) · Sensors · doi:10.3390/s20185274 · Cited by 82
“This device is certified as CE Medical class 2a [66] and has been validated in many works [67,68].”
Methodvan der Mee, D. J., Gevonden, M. J., Westerink, J. H. D. M., & de Geus, E. J. C. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.08.003 · Cited by 70
“14%), although both were modest in keeping with findings for SCL from previous studies (Milstein and Gordon, 2020; Menghini et al., 2019).”
MethodResultXue, T., Ali, A. E., Zhang, T., Ding, G., & Cesar, P. S. (2021) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2021.3124080 · Cited by 77
“(6) We captured participants’ physiological signals through the Empatica E4 wristband6 worn on the non-dominant hand [44], as shown in Fig.”
BackgroundA Critique of Electrodermal Activity Practices at CHI
Babaei, E., Tag, B., Dingler, T., & Velloso, E. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445370 · Cited by 72
“sweat gland activity on the skin of the wrist is mostly representative of thermoregulatory activity, rather than EDA [13] and several validation studies reported unreliability of EDA recordings from wrist measurements [64, 65, 71, 75, 92, 93].”
BackgroundHeart rate variability: Evaluating a potential biomarker of anxiety disorders
Tomasi, J., Zai, C. C. H., Pouget, J. G., Tiwari, A. K., & Kennedy, J. L. (2023) · Psychophysiology · doi:10.1111/psyp.14481 · Cited by 66
Odour enhances the sense of presence in a virtual reality environment
Archer, N., Bluff, A., Eddy, A., Nikhil, C. K., Hazell, N., Frank, D. C., & Johnston, A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0265039 · Cited by 66
Mehmood, I., Li, H., Umer, W., Arsalan, A., Anwer, S., Mirza, M. A., Ma, J., & Antwi‐Afari, M. F. (2023) · Developments in the Built Environment · doi:10.1016/j.dibe.2023.100198 · Cited by 53
“These methods are consistent with the approaches adopted by Milstein and Gordon (2020).”
MethodMultimodal Physiological Signals and Machine Learning for Stress Detection by Wearable Devices
Zhu, L., Spachos, P., & Gregori, S. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856558 · Cited by 43
“In [22]–[24], the authors evaluated and compared the feasibility and reliability of using wearable devices, especially Empatica E4 and Shimmers3, to measure physiological signals.”
BackgroundStuyck, H., Costa, L. D., Axel Cleeremans, B., & den Bussche, E. V. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2022.10.003 · Cited by 44
Tomasi, J., Zai, C. C. H., Zai, G. C., Herbert, D., Richter, M. A., Mohiuddin, A. G., Tiwari, A. K., & Kennedy, J. L. (2024) · Journal of Affective Disorders · doi:10.1016/j.jad.2024.01.137 · Cited by 37
Neurophysiological responses to robot–human interactions in retail stores
Rancati, G., & Maggioni, I. (2022) · Journal of Services Marketing · doi:10.1108/jsm-04-2021-0126 · Cited by 38
Cosoli, G., Mansi, S. A., Pigliautile, I., Pisello, A. L., Revel, G. M., & Arnesano, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.113047 · Cited by 34
Donckt, J. V. D., Vandenbussche, N., Donckt, J. V. D., Chen, S., Stojchevska, M., Brouwer, M. D., Steenwinckel, B., Paemeleire, K., Ongenae, F., & Hoecke, S. V. (2024) · Scientific Reports · doi:10.1038/s41598-024-67767-3 · Cited by 35
Pergantis, P., Bamicha, V., Doulou, A., Christou, A. I., Bardis, N. G., Skianis, C. A., & Drigas, A. S. (2025) · Technologies · doi:10.3390/technologies13040144 · Cited by 38
Alinia, P., Sah, R. K., McDonell, M. G., Pendry, P., Parent, S. C., Ghasemzadeh, H. G., & Cleveland, M. J. (2021) · JMIR Formative Research · doi:10.2196/27891 · Cited by 29
“Previous research has assessed the validity of physiological signals recorded by an Empatica E4 device, such as EDA, HRV, and IBI, against the standard clinical ground truth [13,14].”
MethodHu, X., Sgherza, T. R., Nothrup, J. B., Fresco, D. M., Naragon‐Gainey, K., & Bylsma, L. M. (2024) · Behavior Research Methods · doi:10.3758/s13428-024-02387-3 · Cited by 32
“The ‘floor’ was set as 0.5 μS because previous studies using Empatica E4 regarded SCL below 0.5 μS as problematic (Milstein & Gordon, 2020; van der Mee et al., 2021), and the ‘ceiling’ was set as the default parameter, 60 μS.”
InfluentialCostantini, S., Chiappini, M., Malerba, G., Dei, C., Falivene, A., Arlati, S., Colombo, V. M., Biffi, E., & Storm, F. A. (2023) · Sensors · doi:10.3390/s23208423 · Cited by 31
“This could be due to different reasons: firstly, EDA activity collected through wrist-worn devices has been shown in the past to be potentially unreliable [18].”
BackgroundResultInfluentialBoonprakong, N., Chen, X., Davey, C. E., Tag, B., & Dingler, T. (2023) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3580917 · Cited by 35
“While the device is compact and unobtrusive, recent research has expressed concerns that E4-generated EDA signals are prone to motion artefacts and measurement noise and may not be as reliable as laboratory-grade devices [4, 10, 73].”
BackgroundParreira, J. D., Chalumuri, Y. R., Mousavi, A. S., Modak, M., Zhou, Y., Sanchez-Perez, J. A., Gazi, A. H., Harrison, A. B., Inan, O. T., & Hahn, J. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105001 · Cited by 27
Mehmood, I., Li, H., Umer, W., Ma, J., Shakeel, M. S., Anwer, S., Antwi‐Afari, M. F., Tariq, S., & Wu, H. (2024) · Journal of Safety Research · doi:10.1016/j.jsr.2024.01.013 · Cited by 28
Gullapalli, B. T., Carreiro, S., Chapman, B. P., Ganesan, D., Sjoquist, J., & Rahman, T. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3478107 · Cited by 26
“These raw signals captured from the E4 wristband have been validated in different research settings and are shown to have a performance comparable to the clinically used devices [55, 58, 78].”
MethodDesign and evaluation of an adaptive virtual reality training system
Reyes, C. I. A., Wozniak, D., Ham, A., & Zahabi, M. (2023) · Virtual Reality · doi:10.1007/s10055-023-00827-7 · Cited by 23
“The device has been verified as a reliable and valid tool to measure heart rate variability and electrodermal activity (McCarthy et al. 2016; Milstein Gordon 2020; Schuur-mans et al. 2020).”
MethodKafaei, M., Latifi, M., Burry, J., Ciorciari, J., Aminitabar, A., & Ji, K. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112626 · Cited by 23
Grip Force on Steering Wheel as a Measure of Stress
Sahar, Y., Elbaum, T., WAGNER, M. G., Musicant, O., Hirsh, T., & Shoval, S. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.617889 · Cited by 25
“However, this may result from the different acquisition systems used (Milstein and Gordon, 2020).”
BackgroundEffect of Exposure Time on Thermal Behaviour: A Psychophysiological Approach
Kobaş, B., Koth, S. C., Nkurikiyeyezu, K. N., Giannakakis, G. A., & Auer, T. (2021) · Signals · doi:10.3390/signals2040050 · Cited by 24
“[47].”
Alert-based wearable sensing system for individualized thermal preference prediction
Feng, Y., Wang, J., Wang, N., & Chen, C. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110047 · Cited by 23
Emotion Recognition With Knowledge Graph Based on Electrodermal Activity
Fordson, H. P., Xing, X., Guo, K., & Xu, X. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.911767 · Cited by 24
“Portable low-cost EDA sensors (Milstein and Gordon, 2020) have been developed and applied in a physiological research context as signals become easier to collect.”
BackgroundAnwer, S., Li, H., Antwi‐Afari, M. F., Umer, W., Mehmood, I., & Wong, A. Y. L. (2021) · Engineering Construction & Architectural Management · doi:10.1108/ecam-03-2021-0245 · Cited by 21
SensCon: Embedding Physiological Sensing into Virtual Reality Controllers
Chiossi, F., Kosch, T., Menghini, L., Villa, S., & Mayer, S. (2023) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3604270 · Cited by 21
“ecological VR settings [20], with most of them having been compared with medical-grade devices only in controlled lab settings [77, 78].”
Backgroundde Looff, P. C., Duursma, R. A., Noordzij, M. L., Taylor, S., Jaques, N., Scheepers, F. E., de Schepper, K., & Koldijk, S. (2022) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2022.856544 · Cited by 18
“For instance, the study by Milstein and Gordon (2020) reported that the reliability of the EDA data is questionable in comparison with a ground truth device, while the study by van Lier et al. (2019) suggested that EDA might be useful for strong and sustained stressors.”
BackgroundMethodResultInfluentialCan, Y. S., & Ersoy, C. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2022.3232483 · Cited by 19
“The most distinctive features from the literature for these signals were selected and used [34], [35].”
BackgroundMethodAnalysing the Performance of Stress Detection Models on Consumer-Grade Wearable Devices
Ninh, V.-T., Smyth, S., Tran, M., & Gurrin, C. G. (2021) · Frontiers in artificial intelligence and applications · doi:10.3233/faia210050 · Cited by 19
“concluded that the low-resolution EDA data recorded from Empatica E4 wrist-band, which is a popular wrist-worn device for real-time physiological data streaming, is not reliable [12].”
BackgroundGiordano, F. C., Mitrotti, A., Losurdo, A., Esposito, F., Granata, A. R. M., Pesino, A., Rossini, M., Natale, P., Dileo, V., Fiorentino, M., et al. (2023) · Clinical Kidney Journal · doi:10.1093/ckj/sfad246 · Cited by 18
“BVP, from which heart rate ( HR ) , interbeat intervals ( IBIs ) in milliseconds and heart rate variability ( HRV ) are derived, was recorded in real time [ 37 ].”
MethodKim, W., Seong, M., Kim, K.-J., & Kim, S. (2024) · Scientific Data · doi:10.1038/s41597-024-03132-3 · Cited by 21
Assistive technology for autism spectrum disorder children that experiences stress and anxiety
Pergantis, P., & Drigas, A. S. (2023) · Brazilian Journal of Science · doi:10.14295/bjs.v2i12.426 · Cited by 50
“The research by Milstein & Gordon (2020) was done to examine the validity of this particular device as a purely research tool compared to the MIndwave mobile impendence cardiographic device.”
MethodIoMT-Enabled Stress Monitoring in a Virtual Reality Environment and at Home
Vela, L. M., Crandall, H., Lim, T., Zhang, F., Gibbs, A., Mitchell, A. R. J., Condon, A., Diamond, L. M., Zhang, H., & Sanchez, B. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3240099 · Cited by 16
“These results were consistent with another study where the authors also concluded the Empatica E4 failed to produce reliable HRV data [43].”
ResultErez, C., & Gordon, I. (2024) · Assessment · doi:10.1177/10731911241261168 · Cited by 17
“The signal is filtered for muscle and electrical noise, with visual inspection and manual editing ensuring proper data collection, all performed and analyzed within Mindware’s designated application (as done, for example, in Gordon et al., 2020; Milstein & Gordon, 2020).”
Self-citationWang, Z., Larrazabal, M. A., Rucker, M., Toner, E. R., Daniel, K. E., Kumar, S., Boukhechba, M., Teachman, B. A., & Barnes, L. E. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3610916 · Cited by 15
“Numerous studies have shown that Empatica E4 is accurate and effective in tracking physiological and psychological dynamics and responses in clinical practice and in the wild [28, 48].”
BackgroundJoshi, J., Wang, K., & Cho, Y. (2023) · Sensors · doi:10.3390/s23198244 · Cited by 24
“Furthermore, for settings in which multi-user studies are conducted with remotely located users, researchers have either used time-stamping information [36] or have deployed manual approaches [60] for synchronizing the time-series data.”
BackgroundTriana, A. M., Salmi, J., Hayward, N., Saramäki, J., & Glerean, E. (2024) · PLoS Biology · doi:10.1371/journal.pbio.3002797 · Cited by 19
Torku, A., Chan, A. P. C., Yung, E. H. K., Seo, J., & Antwi‐Afari, M. F. (2022) · Environment and Behavior · doi:10.1177/00139165221114894 · Cited by 15
“In contrast, wearable sensors are mobile and wireless, and can be deployed in a naturalistic environment (Milstein & Gordon, 2020).”
BackgroundCosoli, G., Mansi, S. A., & Arnesano, M. (2022) · IEEE International Workshop on Metrology for Living Environment (MetroLivEnv) · doi:10.1109/metrolivenv54405.2022.9826956 · Cited by 14
Rominger, C., & Schwerdtfeger, A. R. (2022) · Sensors · doi:10.3390/s22082925 · Cited by 14
The Media Psychology of Boredom and Mobile Media Use
Poels, K., Rudnicki, K., & Vandebosch, H. (2022) · Journal of Media Psychology Theories Methods and Applications · doi:10.1027/1864-1105/a000340 · Cited by 13
Howie, E. E., Harari, R., DIAS, R. D., Wigmore, S. J., Skipworth, R. J. E., & Yule, S. (2024) · Journal of Surgical Research · doi:10.1016/j.jss.2024.07.009 · Cited by 13
Lee, V. R. (2021) · Information and Learning Sciences · doi:10.1108/ils-08-2020-0178 · Cited by 13
An Adaptive Virtual Reality-Based Training System for Pilots
Reyes, C. I. A., Wozniak, D., Ham, A., & Zahabi, M. (2022) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181322661063 · Cited by 15
“The device has been used and validated in prior studies to capture these types of data (Milstein & Gordon, 2020; Schuurmans et al., 2020).”
MethodADARP: A Multi Modal Dataset for Stress and Alcohol Relapse Quantification in Real Life Setting
Sah, R. K., McDonell, M. G., Pendry, P., Parent, S. C., Ghasemzadeh, H. G., & Cleveland, M. J. (2022) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn56160.2022.9928495 · Cited by 13
“Previous research has assessed the validity of physiological signals recorded by an Empatica E4, such as EDA, HRV, and IBI, against the standard clinical ground truth [4], [5].”
Xu, R., Cao, S. C., Barnett‐Cowan, M., Bülbül, G. B., Irving, E. L., Niechwiej‐Szwedo, E., & Kearns, S. K. (2025) · MethodsX · doi:10.1016/j.mex.2025.103589 · Cited by 13
“EmbracePlus is a successor to the Empatica E4, a wristband that offers real-time physiological data acquisition and streaming, which is also widely used for research purposes [26,27].”
Frid, L. M., Keßler, U., Ousdal, O. T., Hammar, Å., Haavik, J., Riemer, F., Hirnstein, M., Ersland, L., Erchinger, V. J., Ronold, E. H., et al. (2023) · BMC Psychiatry · doi:10.1186/s12888-023-05239-0 · Cited by 13
A scoping review of wrist-worn wearables in education
Schroeder, N. L., Romine, W. L., & Kemp, S. (2023) · Computers and Education Open · doi:10.1016/j.caeo.2023.100154 · Cited by 12
“However, there have been some questions as to how reliably the E4 can measure GSR [72].”
Reithe, H., Marty, B., Torrado, J. C., Førsund, E., Husebo, B. S., Erdal, A., Kverneng, S. U., Sheard, E., Tzoulis, C., & Pătraşcu, M. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01353-0 · Cited by 11
“Empatica E4 has mixed results for the validity and reliability of both HR and EDA [40, 68–70].”
Altaf, B., Tavakoli, A., Ruth, P. S., Green, A., Xu, J., Jain, S., Chiu, E., Bencharit, L. Z., Murnane, E. L., Landay, J. A., et al. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113147 · Cited by 11
Yan, L., Martínez‐Maldonado, R., Zhao, L., Li, X., & Gašević, D. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-36272-9_49 · Cited by 11
Interpersonal Synchrony Research in Human Groups
Gordon, I. (2025) · Social and Personality Psychology Compass · doi:10.1111/spc3.70068 · Cited by 16
Self-citationLee, S. Y., Kim, J. B., Lee, J. W., Woo, A., Kim, C. J., Chung, M. Y., & Moon, H. S. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12175476 · Cited by 10
“For example, electrodermal activity (EDA) and heart rate variability (HRV) are useful parameters [40,41].”
BackgroundKafaei, M., Burry, J., Latifi, M., Ciorciari, J., & Aminitabar, A. (2024) · Architectural Science Review · doi:10.1080/00038628.2024.2370435 · Cited by 10
A transparency statement improves trust in community-police interactions
Dobson, K. S. H., Dittmann, A. G., & Yeager, D. S. (2025) · Nature Communications · doi:10.1038/s41467-024-55709-6 · Cited by 28
Gao, H., & Ghahramani, A. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116690 · Cited by 11
Machine Learning models for the Cognitive Stress Detection Using Heart Rate Variability Signals
Izzah, N., Sutarto, A. P., & Hariyadi, M. (2022) · Jurnal Teknik Industri · doi:10.9744/jti.24.2.83-94 · Cited by 10
Arasteh, E., Mirian, M. S., Verchere, W. D., Surathi, P., Nene, D., Allahdadian, S., Doo, M., Park, K. W., Ray, S., & McKeown, M. J. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13020265 · Cited by 10
“that computes the reflection coefficient of light (generated by PPG’s light source) from the skin [32].”
BackgroundVacaru, S. V., Lau, L.-P., Frederiks, K., Sterkenburg, P. S., & Barakova, E. I. (2024) · Advanced Robotics · doi:10.1080/01691864.2024.2369797 · Cited by 9
Zhou, Y., Mousavi, A. S., Chalumuri, Y. R., Parreira, J. D., Modak, M., Sanchez-Perez, J. A., Gazi, A. H., Inan, O. T., & Hahn, J. (2024) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2024.09.004 · Cited by 9
The importance of physiological data variability in wearable devices for digital health applications
Cosoli, G., Poli, A., Spinsante, S., & Scalise, L. (2022) · ACTA IMEKO · doi:10.21014/acta_imeko.v11i2.1135 · Cited by 9
“Previous studies underlined that the measurement is not reliable if compared to finger/palm skin conductivity [44]; in fact, thermoregulatory processes would affect the results more than psychophysiological phenomena, which on the contrary are more influencing in the standard measurement sites [45].”
BackgroundRavindran, K. K. G., della Monica, C., Atzori, G., Lambert, D., Revell, V. L., & Dijk, D. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871559 · Cited by 8
“uk studies employed few participants and were not performed in older adults during sleep [2]–[5].”
BackgroundReal-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8
“In the same vein, [26] compared IBI values and cardiac features from E4 with an ambulatory ECG device (VU–AMS) in clinical settings; and [27] collected cardiac features from E4 and another wearable ECG instrument (MindWare Mobile Device).”
BackgroundPhysiological Synchrony in a Collaborative Virtual Reality Task
Moharana, B., Keighrey, C., & Murray, N. (2023) · International Conference on Quality of Multimedia Experience (QoMEX) · doi:10.1109/qomex58391.2023.10178661 · Cited by 11
“Empatica E4 Wristband: The E4 wristband was used to collect the physiological data from participants [31].”
MethodKönig, A., Müller, P., Tröger, J., Lindsay, H., Alexandersson, J., Hinze, J., Riemenschneider, M., Postin, D., Ettore, É., Lecomte, A., et al. (2022) · Personalized Medicine in Psychiatry · doi:10.1016/j.pmip.2022.100094 · Cited by 9
“The heart rate will be automatically calculated with a proprietary algorithm based on the blood volume pulse recorded from a wristband [87].”
Moebus, M., & Holz, C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305258 · Cited by 9
Paloniemi, S., Penttonen, M., Eteläpelto, A., Hökkä, P. K., & Vähäsantanen, K. (2022) · Professional and practice-based learning · doi:10.1007/978-3-031-08518-5_5 · Cited by 11
The Mitigating Effects of Water Sound Attributes on Stress Responses to Traffic Noise
Deng, L., Rising, H. H., Gu, C., & Bimal, A. (2023) · Environment and Behavior · doi:10.1177/00139165241245829 · Cited by 9
“This wearable wireless device allows for real-time computerized biofeedback and data collection, enabling the extrapolation of lab-based research findings to real-world settings (Milstein & Gordon, 2020; Schuurmans et al., 2020).”
de Looff, P. C., Noordzij, M. L., Nijman, H. L. I., Goedhard, L. E., Bogaerts, S., & Didden, R. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1330993 · Cited by 7
“EDA is useful for strong and sustained stressors (63), but the reliability and validity compared to criterion devices is uncertain (61).”
BackgroundCamerini, A.-L., Marciano, L., Annoni, A. M., Ort, A., & Petrocchi, S. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.840845 · Cited by 9
“Validation studies showed that the E4 wristband produced reliable HR data (Schuurmans et al., 2020) but less reliable EDA data (Milstein and Gordon, 2020) compared to other physiological yet less userfriendly measurement tools.”
ResultCosoli, G., Mansi, S. A., Revel, G. M., & Arnesano, M. (2023) · ACTA IMEKO · doi:10.21014/actaimeko.v12i3.1570 · Cited by 7
Coping with emotional pain: An experimental comparison of acceptance vs. avoidance coping
Konstantinou, P., Trigeorgi, A., Georgiou, C., Michaelides, M. P., Gloster, A. T., McHugh, L., Panayiotou, G., & Karekla, M. (2024) · Journal of Contextual Behavioral Science · doi:10.1016/j.jcbs.2024.100820 · Cited by 9
Virtual Reality in Dark Tourism: Multisensory Virtual Tourism Experiences with Thermal Stimuli
Wang, J., Santoso, H. B., Changkaew, L., Tamtama, G. I. W., & Windasari, N. A. (2025) · Journal on Computing and Cultural Heritage · doi:10.1145/3720398 · Cited by 8
“[ 74].”
InfluentialMansi, S. A., Cosoli, G., Pisello, A. L., Pigliautile, I., Revel, G. M., & Arnesano, M. (2022) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot54413.2022.9831610 · Cited by 7
On the Impact of COVID-19 on Subjective Digital Media Quality Assessment
Zepernick, H., Pieper, K., Spang, R. P., Engelke, U., Hirth, M., & Naderi, B. (2021) · IEEE International Workshop on Multimedia Signal Processing (MMSP) · doi:10.1109/mmsp53017.2021.9733583 · Cited by 7
PhysioKit: Open-source, Low-cost Physiological Computing Toolkit for Single and Multi-user StudiesPreprint
Joshi, J., Wang, K., & Cho, Y. (2023) · Preprints.org · doi:10.20944/preprints202308.0545.v1 · Cited by 7
Yan, L., Gašević, D., Echeverría, V., Zhao, L., Jin, Y., Li, X., & Martínez‐Maldonado, R. (2025) · International Journal of Artificial Intelligence in Education · doi:10.1007/s40593-025-00475-9 · Cited by 7
“In contrast, heart rate data, even when collected via wearable sensors, has demonstrated reliability comparable to medical-grade devices (Milstein & Gordon, 2020).”
Transformer-Based Decomposition of Electrodermal Activity for Real-World Mental Health Applications
Tsirmpas, C., Konstantopoulos, S., Andrikopoulos, D., Kyriakouli, K., & Fatouros, P. (2025) · Sensors · doi:10.3390/s25144406 · Cited by 7
“…devices such as the Feel Monitor [10], Empatica E4 [11], and Shimmer3 GSR+ [12] have been widely adopted in clinical and research settings [13, 14, 15, 16, 17, 18], while consumer-grade devices like the Fitbit and Garmin wearables are increasingly being used in mental health monitoring…”
Validity of the Polar H10 for Continuous Measures of Heart Rate and Heart Rate Synchrony Analysis
Chung, V., Chopin, L., Karadayi, J., & Grèzes, J. (2026) · Sensors · doi:10.3390/s26030855 · Cited by 7
“One exception is Milstein and Gordon [13], who validated the accuracy of the Empatica E4 wristband against mobile ECG in naturalistic dyadic interactions.”
Li, D., Lee, C., Park, A. H., Lee, H., & Ding, Y. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1019885 · Cited by 6
Saini, G., Zain, M., Noronha, M., Bonin, R. P., & Lomanowska, A. M. (2024) · Scientific Reports · doi:10.1038/s41598-024-51773-6 · Cited by 9
“The Empatica E4 has been shown to produce reliable and consistent HR and HRV data when compared to other validated tools 68,69 .”
ResultCharlton, P. H., Prada, E. J. A., Mant, J., & Kyriacou, P. A. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adb89e · Cited by 8
BraidFlow: A Flow-annotated Dataset of Kumihimo Braidmaking Activity
Zaman, A., Endow, S., Rakib, M. A. N., & Torres, C. (2023) · Designing Interactive Systems Conference · doi:10.1145/3563657.3596026 · Cited by 6
“Although we planned to place the E4 wristband on the non-dominant hand to minimize motion artifacts[46], we encountered that participants often held”
MethodHasselman, F., den Uil, L., Koordeman, R., de Looff, P. C., & Otten, R. (2023) · Frontiers in Network Physiology · doi:10.3389/fnetp.2023.1289983 · Cited by 6
Frawley, C., & Taylor, D. D. (2024) · Journal of Counseling & Development · doi:10.1002/jcad.12500 · Cited by 8
Effects of labyrinth-like path designs on mitigating stress response to traffic noise
Deng, L., Rising, H. H., Gu, C., & Bimal, A. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111914 · Cited by 6
Melton, K. K., Hodge, C. J., Densley, K., & Sturdivant, R. X. (2024) · Journal of Leisure Research · doi:10.1080/00222216.2024.2315051 · Cited by 5
“Scosche Rhythm sensors use the Valencell® biometric chip, which has been benchmarked for providing above 99% reliability (Milstein and Gordon, 2020; Stahl et al., 2016).”
Zhou, Y., Parreira, J. D., Shahrbabak, S. M., Sanchez-Perez, J. A., Rahman, F. N., Gazi, A. H., Inan, O. T., & Hahn, J. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3453121 · Cited by 5
Toner, E. R., Rucker, M., Wang, Z., Larrazabal, M. A., Cai, L., Datta, D., Lone, H. R., Boukhechba, M., Teachman, B. A., & Barnes, L. E. (2025) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2025.3562787 · Cited by 12
“This suggests that EDA frequency domain features may be robust to movement artifacts, a commonly observed problem with Empatica E4 EDA sensors [65].”
InfluentialRho, G., Rienzo, F. D., Marinai, C., Giannetti, F., Arcarisi, L., Bufano, P., Zanoletti, M., Righetti, F., Vallati, C., Laurino, M., et al. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49062-0_3 · Cited by 5
Stritzelberger, J., Kirmse, M., Borutta, M. C., Gollwitzer, S., Reindl, C., Welte, T. M., Hamer, H. M., & Koehn, J. (2025) · Diagnostics · doi:10.3390/diagnostics15202604 · Cited by 4
Kondaurova, M. V., Smith, A. F., Mishra, R., Zheng, Q., Kondaurova, I., Francis, A. L., & Sallee, E. (2024) · American Journal of Audiology · doi:10.1044/2024_aja-24-00078 · Cited by 4
Validation of WeBe Band During Physical Activities
Fang, R., Hang, S., Zhang, R., Fang, C., Rafatirad, S., Hostinar, C. E., & Homayoun, H. (2024) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn63547.2024.10780730 · Cited by 4
Siche-Pantel, F., Mühlenberg, M., Buschfort, R., Michels, H., Jakobsmeyer, R., Oesterschlink, J., & Reinsberger, C. (2025) · BMC Neurology · doi:10.1186/s12883-025-04281-7 · Cited by 4
“In sitting rest positions, it shows high validity in heart rate variability and medium validity in electrodermal activity measurements [24].”
Nijman, H. L. I., Jakobs, A., Waters, M., Osborne, N., Moerbeek, M., Herstel, A., & de Looff, P. C. (2022) · Psychology of Music · doi:10.1177/03057356221111823 · Cited by 4
“Validation studies of assessments made with the Empatica E4 have yielded positive results (e.g., Menghini et al., 2019; Milstein & Gordon, 2020; Schuurmans et al., 2020; van Lier et al., 2020).”
Result
Metadata
- Authors
- Milstein, N., & Gordon, I.
- Affiliations
- Bar-Ilan University (IL)
- Corresponding author
- Gordon, Ilanit
- Venue
- Frontiers in Behavioral Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2020-08-18
- Volume
- 14
- Pages
- 148-148
- ISSN
- 1662-5153 (ISSN-L)
- OpenAlex
- W3058974884
- Cited by
- 180
- References
- 43
- Citations by year
- 2026: 28 · 2025: 29 · 2024: 32 · 2023: 44 · 2022: 29 · 2021: 17 · 2020: 1
- FWCI
- 14.08
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Behavioral Neuroscience (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Israel Science Foundation
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- Empatica E4, electrodermal activity, heart rate variability, RR interval, device validation, dyadic therapy, face-to-face communication, naturalistic interaction, psychophysiological measurement, measurement reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review