Automatic Measurements of Fetal Lateral Ventricles in 2D Ultrasound Images Using Deep Learning
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Measurement of the width of fetal lateral ventricles (LVs) in prenatal ultrasound (US) images is essential for antenatal neuronographic assessment. However, the manual measurement of LV width is highly subjective and relies on the clinical experience of scanners. To deal with this challenge, we propose a computer-aided detection framework for automatic measurement of fetal LVs in two-dimensional US images. First, we train a deep convolutional network on 2,400 images of LVs to perform pixel-wise segmentation. Then, the number of pixels per centimeter (PPC), a vital parameter for quantifying the caliper in US images, is obtained via morphological operations guided by prior knowledge. The estimated PPC, upon conversion to a physical length, is used to determine the diameter of the LV by employing the minimum enclosing rectangle method. Extensive experiments on a self-collected dataset demonstrate that the proposed method achieves superior performance over manual measurement, with a mean absolute measurement error of 1.8 mm. The proposed method is fully automatic and is shown to be capable of reducing measurement bias caused by improper US scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Villar, J., Ismail, L. C., Victora, C. G., Ohuma, E. O., Bertino, E., Altman, D. G., Lambert, A., Papageorghiou, A. T., Carvalho, M., Jaffer, Y. A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60932-6 · Cited by 2,281
Zou, Q., Xing, P., Wei, L., & Liu, B. (2019) · RNA · doi:10.1261/rna.069112.118 · Cited by 525
Automated measurement of fetal head circumference using 2D ultrasound images
van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200412 · Cited by 280
Multi-task learning for quality assessment of fetal head ultrasound images
Lin, Z., Li, S., Ni, D., Liao, Y., Wen, H., Du, J., Chen, S., Wang, T., & Lei, B. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101548 · Cited by 129 · cited 1×
“…of protein function (13), classification of non-metastatic nasopharyngeal carcinomas (14), discovery of m6A sequences (15), image segmentation using new iterative tri-class thresholding techniques (16), qualitative assessment of fetal head US images (17), and detection of breast cancer (18).”
MethodLi, J., Wang, Y., Lei, B., Cheng, J.-Z., Qin, J., Wang, T., Li, S., & Ni, D. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2703890 · Cited by 120 · cited 1×
“Although the automatic measurement of fetal biometrics—such as head circumference (7, 8) and femur length (9, 10)—has attracted widespread attention in recent years, work on fetal LV measurement is rare.”
Cited by
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
“Additionally, DL models can be trained to perform automatic measurements of fetal brain structures, such as the lateral ventricles or cavum septi pellucidi 66,67 .”
MethodArtificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
Lin, M., He, X., Guo, H., He, M., Zhang, L., Xian, J., Lei, T., Xu, Q., Zheng, J., Feng, J., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24843 · Cited by 65
Self-citationDeepGA for automatically estimating fetal gestational age through ultrasound imaging
Dan, T., Chen, X., He, M., Guo, H., He, X., Chen, J., Xian, J., Hu, Y., Zhang, B., Wang, N., et al. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102453 · Cited by 25
Self-citationWu, H., Wu, B., Lai, F., Liu, P., Lyu, G., He, S., & Dai, J. (2023) · Computational and Mathematical Methods in Medicine · doi:10.1155/2023/5650378 · Cited by 20
“Chen [12] used deep learning (DL) to automatically measure the width of fetal lateral ventricle in 2D ultrasound images.”
Method
Metadata
- Authors
- Chen, X., He, M., Dan, T., Wang, N., Lin, M., Zhang, L., Xian, J., Cai, H., & Xie, H.
- Venue
- Frontiers in Neurology
- Publisher
- Frontiers Media SA
- Published
- 2020-07-17
- Volume
- 11
- Pages
- 526-526
- ISSN
- 1664-2295 (ISSN-L)
- OpenAlex
- W3043406427
- Cited by
- 36
- References
- 6
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Measurements of Fetal Lateral Ventricles in 2D Ultrasound Images Using Deep Learning. https://app.cochat.ai/papers/10.3389/fneur.2020.00526
- The paper
- Chen, X., He, M., Dan, T., Wang, N., Lin, M., Zhang, L., Xian, J., Cai, H., & Xie, H. (2020). Automatic Measurements of Fetal Lateral Ventricles in 2D Ultrasound Images Using Deep Learning. Frontiers in Neurology. https://doi.org/10.3389/fneur.2020.00526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.