A comparison of two sleep spindle detection methods based on all night averages: individually adjusted vs. fixed frequencies
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Sleep spindles are frequently studied for their relationship with state and trait cognitive variables, and they are thought to play an important role in sleep-related memory consolidation. Due to their frequent occurrence in NREM sleep, the detection of sleep spindles is only feasible using automatic algorithms, of which a large number is available. We compared subject averages of the spindle parameters computed by a fixed frequency (FixF) (11-13 Hz for slow spindles, 13-15 Hz for fast spindles) automatic detection algorithm and the individual adjustment method (IAM), which uses individual frequency bands for sleep spindle detection. Fast spindle duration and amplitude are strongly correlated in the two algorithms, but there is little overlap in fast spindle density and slow spindle parameters in general. The agreement between fixed and manually determined sleep spindle frequencies is limited, especially in case of slow spindles. This is the most likely reason for the poor agreement between the two detection methods in case of slow spindle parameters. Our results suggest that while various algorithms may reliably detect fast spindles, a more sophisticated algorithm primed to individual spindle frequencies is necessary for the detection of slow spindles as well as individual variations in the number of spindles in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sleep Spindles in Humans: Insights from Intracranial EEG and Unit Recordings
Andrillon, T., Nir, Y., Staba, R. J., Ferrarelli, F., Cirelli, C., Tononi, G., & Fried, I. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2604-11.2011 · Cited by 504 · cited 2×
“Negative spindle chirps (decreasing frequencies) have been reported in humans (Andrillon et al., 2011; Schonwald et al., 2011), while increasing spindle frequencies were reported in rats (Sitnikova et al., 2014).”
BackgroundCarrier, J., Land, S., Buysse, D. J., Kupfer, D. J., & Monk, T. H. (2001) · Psychophysiology · doi:10.1111/1469-8986.3820232 · Cited by 494
Hemodynamic cerebral correlates of sleep spindles during human non-rapid eye movement sleep
Schabus, M., Dang-Vu, T. T., Albouy, G., Balteau, E., Boly, M., Carrier, J., Darsaud, A., Degueldre, C., Desseilles, M., Gais, S., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703084104 · Cited by 488 · cited 4×
“All procedures were approved by the responsible institution’s ethical board and subjects gave informed consent.”
MethodInfluentialOvernight verbal memory retention correlates with the number of sleep spindles
Clemens, Z., Fabó, D., & Halász, P. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2005.01.011 · Cited by 405
Learning‐dependent changes in sleep spindles and Stage 2 sleep
FOGEL, S. M., & SMITH, C. T. (2006) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2006.00522.x · Cited by 344 · cited 1×
“…in psychometric variables separated slow and fast spindles: many analyzed sleep spindles in general or spectral power from a broader frequency band (Clemens et al., 2005; Fogel and Smith, 2006; Fogel et al., 2007; Tucker and Fishbein, 2009; Lustenberger et al., 2012; Gruber et al., 2013).”
BackgroundSchabus, M., Hödlmoser, K., Gruber, G., Sauter, C., Anderer, P., Klösch, G., Parapatics, S., Saletu, B., Klimesch, W., & Zeitlhofer, J. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04694.x · Cited by 261 · cited 5×
“These frequencies were selected to ensure consistency with previous studies (Schabus et al., 2006, 2007, 2008; Chatburn et al., 2013), which used a similar approach for the separation of slow and fast spindles.”
BackgroundMethodInfluentialAn electroencephalographic fingerprint of human sleep
De Gennaro, L., Ferrara, M., Vecchio, F., Curcio, G., & Bertini, M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.020 · Cited by 247 · cited 8×
“ORIGINAL RESEARCH ARTICLE published: 17 February 2015 doi: 10.3389/fnhum.2015.00052”
BackgroundMethodInfluentialPrediction of general mental ability based on neural oscillation measures of sleep
BÓDIZS, R., KIS, T., LÁZÁR, A. S., HAVRÁN, L., RIGÓ, P., CLEMENS, Z., & HALÁSZ, P. (2005) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2005.00472.x · Cited by 190
Self-citationSleep spindles and learning potential.
Fogel, S. M., Nader, R., Cote, K. A., & Smith, C. T. (2007) · Behavioral Neuroscience · doi:10.1037/0735-7044.121.1.1 · Cited by 188 · cited 3×
“Sleep spindles are not only biological signals, but important markers of individual traits (De Gennaro et al., 2005, 2008) as well as powerful correlates of human cognition (among others: Bódizs et al., 2005; Schabus et al., 2006; Fogel et al., 2007; Ujma et al., 2014).”
BackgroundInterindividual sleep spindle differences and their relation to learning-related enhancements
Schabus, M., Hoedlmoser, K., Pecherstorfer, T., Anderer, P., Gruber, G., Parapatics, S., Sauter, C., Kloesch, G., Klimesch, W., Saletu, B., et al. (2008) · Brain Research · doi:10.1016/j.brainres.2007.10.106 · Cited by 174 · cited 3×
“That is, both slow and fast sleep spindle measures correlate with cognitive abilities in cases when the FixF method is used (Schabus et al., 2006, 2008), while in case of IAM fast spindles are much more stable correlates of cognitive performance (Bódizs et al., 2005, 2008; Ujma et al., 2014).”
BackgroundMethod
Cited by
Sleep spindles: mechanisms and functions
Fernandez, L. M. J., & Lüthi, A. (2020) · Physiological Reviews · doi:10.1152/physrev.00042.2018 · Cited by 716
Oscillating circuitries in the sleeping brain
Adamantidis, A. R., Gutierrez Herrera, C., & Gent, T. C. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0223-4 · Cited by 281
Slow oscillation-spindle coupling predicts enhanced memory formation from childhood to adolescence
Hahn, M. A., Heib, D., Schabus, M., Hoedlmoser, K., & Helfrich, R. F. (2020) · eLife · doi:10.7554/elife.53730 · Cited by 140
“Furthermore, our results highlight the critical need to account for individual oscillatory features and to discount non-oscillatory broadband effects, which are known to confound cross-frequency coupling analyses (Figure 4—figure supplement 1D,E,G; Aru et al., 2015; Bódizs et al., 2009; Cole and Voytek, 2017; Ujma et…”
BackgroundNREM2 and sleep spindles are instrumental to the consolidation of motor sequence memories
Laventure, S., Fogel, S., Lungu, O., Albouy, G., Sévigny-Dupont, P., Vien, C., Sayour, C., Carrier, J., Benali, H., & Doyon, J. (2016) · PLoS Biology · doi:10.1371/journal.pbio.1002429 · Cited by 132
Temporal associations between sleep slow oscillations, spindles and ripples
Oyanedel, C. N., Durán, E., Niethard, N., Inostroza, M., & Born, J. (2020) · European Journal of Neuroscience · doi:10.1111/ejn.14906 · Cited by 71
Metadata
- Authors
- Ujma, P. P., Gombos, F., Genzel, L., Konrad, B. N., Simor, P., Steiger, A., Dresler, M., & Bódizs, R.
- Venue
- Frontiers in Human Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2015-02-17
- Volume
- 9
- Pages
- 415-415
- ISSN
- 1662-5161 (ISSN-L)
- OpenAlex
- W2026917669
- Cited by
- 63
- References
- 12
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of two sleep spindle detection methods based on all night averages: individually adjusted vs. fixed frequencies. https://app.cochat.ai/papers/10.3389/fnhum.2015.00052
- The paper
- Ujma, P. P., Gombos, F., Genzel, L., Konrad, B. N., Simor, P., Steiger, A., Dresler, M., & Bódizs, R. (2015). A comparison of two sleep spindle detection methods based on all night averages: individually adjusted vs. fixed frequencies. Frontiers in Human Neuroscience. https://doi.org/10.3389/fnhum.2015.00052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.