The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
Abstract
Electroencephalography (EEG) recordings represent a vital component of the assessment of sleep physiology, but the methodology presently used is costly, intrusive to participants, and laborious in application. There is a recognized need to develop more easily applicable yet reliable EEG systems that allow unobtrusive long-term recording of sleep-wake EEG ideally away from the laboratory setting. cEEGrid is a recently developed flex-printed around-the-ear electrode array, which holds great potential for sleep-wake monitoring research. It is comfortable to wear, simple to apply, and minimally intrusive during sleep. Moreover, it can be combined with a smartphone-controlled miniaturized amplifier and is fully portable. Evaluation of cEEGrid as a motion-tolerant device is ongoing, but initial findings clearly indicate that it is very well suited for cognitive research. The present study aimed to explore the suitability of cEEGrid for sleep research, by testing whether cEEGrid data affords the signal quality and characteristics necessary for sleep stage scoring. In an accredited sleep laboratory, sleep data from cEEGrid and a standard PSG system were acquired simultaneously. Twenty participants were recorded for one extended nocturnal sleep opportunity. Fifteen data sets were scored manually. Sleep parameters relating to sleep maintenance and sleep architecture were then extracted and statistically assessed for signal quality and concordance. The findings suggest that the cEEGrid system is a viable and robust recording tool to capture sleep and wake EEG. Further research is needed to fully determine the suitability of cEEGrid for basic and applied research as well as sleep medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“So far, early validation studies have shown feasible and accessible ways to acquire sleep data in newer montages and a moderate range of agreement on the group level for all sleep staging combined based on blinded rated AASM scoring [38].”
From Clinician-Focused Overview and Developments in Polysomnography (2020) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Short- and long-term health consequences of sleep disruption
Medic, G., Wille, M., & Hemels, M. (2017) · Nature and Science of Sleep · doi:10.2147/nss.s134864 · Cited by 1,776
Research works printed but not linked: 21
- Bleichner, 2017, Concealed, unobtrusive ear-centered EEG acquisition: cEEGrids for transparent EEG., Front. Hum. Neurosci., 11, 10.3389/fnhum.2017.00163 · DOI · Paper page
- Bleichner, 2016, Identifying auditory attention with ear-EEG: cEEGrid versus high-density cap-EEG comparison., J. Neural Eng., 13, 10.1088/1741-2560/13/6/066004 · DOI
- Bruyneel, 2014, Unattended home-based polysomnography for sleep disordered breathing: current concepts and perspectives., Sleep Med. Rev., 18, 341, 10.1016/J.SMRV.2013.12.002 · DOI
- Bruyneel, 2011, Sleep efficiency during sleep studies: results of a prospective study comparing home-based and in-hospital polysomnography., J. Sleep Res., 20, 201, 10.1111/j.1365-2869.2010.00859.x · DOI
- Buysse, 1989, The pittsburgh sleep quality index: a new instrument for psychiatric practice and research., Psychiatry Res., 28, 193, 10.1016/0165-1781(89)90047-4 · DOI · Paper page
- Campbell, 2011, Home set-up polysomnography in the assessment of suspected obstructive sleep apnea., J. Sleep Res., 20, 207, 10.1111/j.1365-2869.2010.00854.x · DOI · Paper page
- Debener, 2015, Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear., Sci. Rep., 5, 10.1038/srep16743 · DOI · Paper page
- Edinger, 1997, Sleep in the laboratory and sleep at home: comparisons of older insomniacs and normal sleepers., Sleep, 20, 1119, 10.1093/sleep/20.12.1119 · DOI · Paper page
- Edinger, 2001, Sleep in the laboratory and sleep at home II: comparisons of middle-aged insomnia sufferers and normal sleepers., Sleep, 24, 761, 10.1093/sleep/24.7.761 · DOI
- Fry, 1998, Full polysomnography in the home., Sleep, 21, 635, 10.1093/sleep/21.6.635 · DOI
- Horne, 1976, A self-assessment questionnaire to determine morningness-eveningness in human circadian rhythms., Int. J. Chronobiol., 4, 97
- Iber, 2004, Polysomnography performed in the unattended home versus the attended laboratory setting—sleep heart health study methodology., Sleep, 27, 536, 10.1093/sleep/27.3.536 · DOI · Paper page
- Kingshott, 2000, The effect of in-laboratory polysomnography on sleep and objective daytime sleepiness., Sleep, 23, 1109, 10.1093/sleep/23.8.1j · doi:10.1093/sleep/23.8.1j
- Kotz, 2016, Target speaker detection with concealed EEG around the ear., Front. Neurosci., 10, 10.3389/fnins.2016.00349 · DOI
- Landis, 1977, The measurement of observer agreement for categorical data., Biometrics, 33, 159, 10.2307/2529310 · DOI · Paper page
- Levendowski, 2017, The accuracy, night-to-night variability, and stability of frontopolar sleep electroencephalography biomarkers., J. Clin. Sleep Med., 13, 791, 10.5664/jcsm.6618 · DOI
- Loomis, 1937, Cerebral states during sleep, as studied by human brain potentials., J. Exp. Psychol., 21, 127, 10.1037/h0057431 · DOI · Paper page
- Mirkovic, 2016, Target speaker detection with concealed EEG around the ear., Front. Neurosci., 10, 10.3389/fnins.2016.00349 · DOI
- Pacharra, 2017, Concealed around-the-ear EEG captures cognitive processing in a visual simon task., Front. Hum. Neurosci., 11, 10.3389/fnhum.2017.00290 · DOI
- Portier, 2000, Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome., Am. J. Respir. Crit. Care Med., 162, 814, 10.1164/ajrccm.162.3.9908002 · DOI · Paper page
- Younes, 2017, Performance of a new portable wireless sleep monitor., J. Clin. Sleep Med., 13, 245, 10.5664/jcsm.6456 · DOI
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Arnal, P. J., Thorey, V., Debellemaniere, E., Ballard, M. E., Bou Hernandez, A., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., et al. (2020) · SLEEP · doi:10.1093/sleep/zsaa097 · Cited by 394
Recent advances in wearable sensors and portable electronics for sleep monitoring
Kwon, S., Kim, H., & Yeo, W.-H. (2021) · iScience · doi:10.1016/j.isci.2021.102461 · Cited by 209
Clinician-Focused Overview and Developments in Polysomnography
Markun, L. C., & Sampat, A. (2020) · Current Sleep Medicine Reports · doi:10.1007/s40675-020-00197-5 · Cited by 136
A Review of Recurrent Neural Network-Based Methods in Computational Physiology
Mao, S., & Sejdić, E. (2023) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2022.3145365 · Cited by 128
Metadata
- Authors
- Sterr, A., Ebajemito, J. K., Mikkelsen, K. B., Bonmati-Carrion, M. A., Santhi, N., della Monica, C., Grainger, L., Atzori, G., Revell, V., Debener, S., Dijk, D.-J., & DeVos, M.
- Venue
- Frontiers in Human Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2018-11-26
- Volume
- 12
- ISSN
- 1662-5161
- Cited by
- 89
- References
- 2
- Funders
- Engineering and Physical Sciences Research Council (EP/K503939/1)
- Wellcome Trust (098461/Z/12/Z)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.