The Redox Balance in Erythrocytes, Plasma, and Periosteum of Patients with Titanium Fixation of the Jaw
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Titanium miniplates and screws are commonly used for fixation of fractured or osteotomised jaws. Despite the opinion of their biocompatibility, in clinical practice symptoms of chronic inflammation around the fixation develop in some patients, even many years after the application of miniplates and screws. The cause of these complications is still an open question. Taking into account that oxidative stress is one of the toxic action of titanium, we have evaluated the antioxidant barrier as well as oxidative stress in the erythrocytes, plasma and periosteum covering the titanium fixation of the jaws. The study group was composed of 32 patients aged 20–30 with inserted miniplates and screws. Antioxidant defence: catalase (CAT), glutathione peroxidase (GPx), superoxide dismutase-1 (SOD1), uric acid (UA), total antioxidant capacity (TAC), as well as oxidative damage products: advanced oxidation protein products (AOPP), advanced glycation end products (AGE), dityrosine, kynurenine, N-formylkynurenine, tryptophan, malondialdehyde (MDA), 4-hydroxynonenal (4-HNE), total oxidant status (TOS), and oxidative status index (OSI) were evaluated. SOD1 activity (↓37%), and tryptophan levels (↓34%) showed a significant decrease while AOPP (↑25%), TOS (↑80%) and OSI (↑101%) were significantly elevated in maxillary periosteum of patients who underwent bimaxillary osteotomies as compared to the control group. SOD-1 (↓55%), TAC (↓58.6%), AGE (↓60%) and N-formylkynurenine (↓34%) was statistically reduced while AOPP (↑38%), MDA (↑29%), 4-HNE (↑114%), TOS (↑99%) and OSI (↑381%) were significantly higher in the mandibular periosteum covering miniplates/screw compared with the control tissues. There were no correlations between antioxidants and oxidative stress markers in the periosteum of all patients and the blood. As exposure to the Ti6Al4V titanium alloy leads to disturbances of redox balance in the periosteum surrounding titanium implants of the maxilla and the mandible so antioxidant supplementation should be recommended to the patients undergoing treatment of dentofacial deformities with the use of titanium implants. The results we obtained may also indicate a need to improve the quality of titanium jaw fixations through increase of TiO2 passivation layer thickness or to develop new, the most highly biodegradable materials for their production.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogen peroxide in the human body
Halliwell, B., Clement, M. V., & Long, L. H. (2000) · FEBS Letters · doi:10.1016/s0014-5793(00)02197-9 · Cited by 1,075 · cited 1×
“Moreover, the cathodic part of the corrosion of titanium implants, at physiological pH, reduces oxygen to hydrogen peroxide, which indeed is not a free radical, but has oxidizing ability of both proteins and lipids (Haliwell et al., 2000).”
Background
Cited by
Schlundt, C., Fischer, H., Bucher, C. H., Rendenbach, C., Duda, G. N., & Schmidt-Bleek, K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.052 · Cited by 415
The Status of Women in STEM in Higher Education: A Review of the Literature 2007–2017
Blackburn, H. (2017) · Science & Technology Libraries · doi:10.1080/0194262x.2017.1371658 · Cited by 353
Choromańska, M., Klimiuk, A., Kostecka-Sochoń, P., Wilczyńska, K., Kwiatkowski, M., Okuniewska, N., Waszkiewicz, N., Zalewska, A., & Maciejczyk, M. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18102205 · Cited by 87
Self-citationUrine 3-Nitrotyrosine and serum HDL as potential biomarkers of depression
Nobis, A., Zalewski, D., Samaryn, E., Maciejczyk, M., Zalewska, A., & Waszkiewicz, N. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12010377 · Cited by 12
Self-citation
Metadata
- Authors
- Borys, J., Maciejczyk, M., Krȩtowski, A. J., Antonowicz, B., Ratajczak-Wrona, W., Jabłońska, E., Załęski, P., Waszkiel, D., Ładny, J. R., Żukowski, P., & Zalewska, A.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2017-06-07
- Volume
- 8
- Pages
- 386-386
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2624346448
- Cited by
- 55
- References
- 1
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Redox Balance in Erythrocytes, Plasma, and Periosteum of Patients with Titanium Fixation of the Jaw. https://app.cochat.ai/papers/10.3389/fphys.2017.00386
- The paper
- Borys, J., Maciejczyk, M., Krȩtowski, A. J., Antonowicz, B., Ratajczak-Wrona, W., Jabłońska, E., Załęski, P., Waszkiel, D., Ładny, J. R., Żukowski, P., & Zalewska, A. (2017). The Redox Balance in Erythrocytes, Plasma, and Periosteum of Patients with Titanium Fixation of the Jaw. Frontiers in Physiology. https://doi.org/10.3389/fphys.2017.00386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.