Rationale, Implementation and Evaluation of Assistive Strategies for an Active Back-Support Exoskeleton
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Active exoskeletons are potentially more effective and versatile than passive ones, but designing them poses a number of additional challenges. An important open challenge in the field is associated to the assistive strategy, by which the actuation forces are modulated to the user's needs during the physical activity. This paper addresses this challenge on an active exoskeleton prototype aimed at reducing compressive low-back loads, associated to risk of musculoskeletal injury during manual material handling (i.e., repeatedly lifting objects). An analysis of the biomechanics of the physical task reveals two key factors that determine low-back loads. For each factor, a suitable control strategy for the exoskeleton is implemented. The first strategy is based on user posture and modulates the assistance to support the wearer's own upper body. The second one adapts to the mass of the lifted object and is a practical implementation of electromyographic control. A third strategy is devised as a generalized combination of the first two. With these strategies, the proposed exoskeleton can quickly adjust to different task conditions (which makes it versatile compared to using multiple, task-specific, devices) as well as to individual preference (which promotes user acceptance). Additionally, the presented implementation is potentially applicable to more powerful exoskeletons, capable of generating larger forces. The different strategies are implemented on the exoskeleton and tested on 11 participants in an experiment reproducing the lifting task. The resulting data highlights that the strategies modulate the assistance as intended by design, i.e., they effectively adjust the commanded assistive torque during operation based on user posture and external mass. The experiment also provides evidence of significant reduction in muscular activity at the lumbar spine (around 30%) associated to using the exoskeleton. The reduction is well in line with previous literature and may be associated to lower risk of injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revised NIOSH equation for the design and evaluation of manual lifting tasks
WATERS, T. R., PUTZ-ANDERSON, V., GARG, A., & FINE, L. J. (1993) · Ergonomics · doi:10.1080/00140139308967940 · Cited by 2,042
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Self-citationControl strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Norman, R., Wells, R., Neumann, P., Frank, J., Shannon, H., & Kerr, M. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00020-5 · Cited by 658
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Self-citationA myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
A Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 412
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Hayashi, T., Kawamoto, H., & Sankai, Y. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545505 · Cited by 377
Coenen, P., Gouttebarge, V., van der Burght, A. S. A. M., van Dieën, J. H., Frings-Dresen, M. H. W., van der Beek, A. J., & Burdorf, A. (2014) · Occupational and Environmental Medicine · doi:10.1136/oemed-2014-102346 · Cited by 318 · cited 4×
“(1998); Coenen et al. (2014); OHSA (European Agency for Safety and Health at Work) (2000). Indeed, a large part of the cases of absence from work is associated to the spine, making the area most subject to disorders1. Guidelines for workplace safety and ergonomics often result in very strict limitations on the weights…”
BackgroundInfluentialHuysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 313
Self-citationCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258 · cited 7×
“(2011); Giovacchini et al. (2015); Ruiz Garate et al. (2017) with applications in elbow and hip assistance. It is helpful to highlight here that sensors for joints orientation are usually well integrated in the exoskeleton and are therefore little obtrusive. However, reproducing profiles in loops is less suited for no…”
BackgroundMethodInfluentialOscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
Non-invasive control interfaces for intention detection in active movement-assistive devices
Lobo-Prat, J., Kooren, P. N., Stienen, A. H. A., Herder, J. L., Koopman, H. F. J. M., & Veltink, P. H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-168 · Cited by 173
Kim, W., Lee, J., Peternel, L., Tsagarakis, N. G., & Ajoudani, A. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2729666 · Cited by 138
Walking assist device with bodyweight support system
Ikeuchi, Y., Ashihara, J., Hiki, Y., Kudoh, H., & Noda, T. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354543 · Cited by 116
Young, A. J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00037 · Cited by 86
International Conference on Rehabilitation Robotics
(2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1371618 · Cited by 85
Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630872 · Cited by 75
Self-citationGarate, V. R., Parri, A., Yan, T., Munih, M., Lova, R. M., Vitiello, N., & Ronsse, R. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00015 · Cited by 67
A Powered Low-Back Exoskeleton for Industrial Handling: Considerations on Controls
Toxiri, S., Ortiz, J., Masood, J., Fernández, J., Mateos, L. A., & Caldwell, D. G. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46532-6_47 · Cited by 27
Self-citationA novel human effort estimation method for knee assistive exoskeletons
Saccares, L., Brygo, A., Sarakoglou, I., & Tsagarakis, N. G. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009423 · Cited by 26
Man to Machine, Applications in Electromyography
Wehner, M. (2012) · InTech eBooks · doi:10.5772/26495 · Cited by 16
Gastrocnemius myoelectric control of a robotic hip exoskeleton
Grazi, L., Crea, S., Parri, A., Yan, T., Cortese, M., Giovacchini, F., Cempini, M., Pasquini, G., Micera, S., & Vitiello, N. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319241 · Cited by 15 · cited 10×
“An additional study by the same group successfully showed that a device assisting one joint may even be controlled via a muscle acting on a different joint, as long as the two muscle groups are activated in coordination during the target task Grazi et al. (2015). These findings encourage further research towards the s…”
BackgroundInfluentialMeattini, R., Palli, G., & Melchiorri, C. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009236 · Cited by 12
Cited by
Logistics 4.0: a systematic review towards a new logistics system
Winkelhaus, S., & Grosse, E. H. (2020) · International Journal of Production Research · doi:10.1080/00207543.2019.1612964 · Cited by 797
Kermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Self-citationOjha, A., Gautam, Y., Jebelli, H., & Akanmu, A. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105742 · Cited by 39
Metadata
- Authors
- Toxiri, S., Koopman, A. S., Lazzaroni, M., Ortiz, J., Power, V., de Looze, M. P., O'Sullivan, L., & Caldwell, D. G.
- Venue
- Frontiers in Robotics and AI
- Publisher
- Frontiers Media SA
- Published
- 2018-05-25
- Volume
- 5
- Pages
- 53-53
- ISSN
- 2296-9144 (ISSN-L)
- OpenAlex
- W2801932927
- Cited by
- 171
- References
- 31
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.