Intraoperative Fluorescence Imaging for Personalized Brain Tumor Resection: Current State and Future Directions
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Fluorescence-guided surgery is one of the rapidly emerging methods of surgical "theranostics." In this review, we summarize current fluorescence techniques used in neurosurgical practice for brain tumor patients as well as future applications of recent laboratory and translational studies. METHODS: Review of the literature. RESULTS: A wide spectrum of fluorophores that have been tested for brain surgery is reviewed. Beginning with a fluorescein sodium application in 1948 by Moore, fluorescence-guided brain tumor surgery is either routinely applied in some centers or is under active study in clinical trials. Besides the trinity of commonly used drugs (fluorescein sodium, 5-aminolevulinic acid, and indocyanine green), less studied fluorescent stains, such as tetracyclines, cancer-selective alkylphosphocholine analogs, cresyl violet, acridine orange, and acriflavine, can be used for rapid tumor detection and pathological tissue examination. Other emerging agents, such as activity-based probes and targeted molecular probes that can provide biomolecular specificity for surgical visualization and treatment, are reviewed. Furthermore, we review available engineering and optical solutions for fluorescent surgical visualization. Instruments for fluorescent-guided surgery are divided into wide-field imaging systems and hand-held probes. Recent advancements in quantitative fluorescence-guided surgery are discussed. CONCLUSION: We are standing on the threshold of the era of marker-assisted tumor management. Innovations in the fields of surgical optics, computer image analysis, and molecular bioengineering are advancing fluorescence-guided tumor resection paradigms, leading to cell-level approaches to visualization and resection of brain tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476 · cited 1×
“However, the safety of quantum dots is significant because larger quantum dots may not be well cleared, and the long-term effects of accumulation are unknown (218, 219).”
BackgroundPENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423 · cited 2×
“5-month increase in progression-free survival with 5-ALA fluorescenceguided surgery (111).”
BackgroundIn vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778 · cited 4×
“CH1055 (70) ~750 nm 1055 nm In-house-built NIR spectroscopy instrument with Acton SP2300i spectrometer (Princeton Instruments, Trenton, NJ, USA) and Princeton OMA-V liquid-nitrogen-cooled InGaAs linear array detector (Princeton Instruments) Xenograft mice model (U87MG human glioblastoma) High tumor-to-background signa…”
BackgroundMethodInfluentialFunctional Outcome after Language Mapping for Glioma Resection
Sanai, N., Mirzadeh, Z., & Berger, M. S. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa067819 · Cited by 1,065 · cited 1×
“Building on earlier work, intraoperative electrophysiological monitoring and cortical and subcortical mapping performed with the patient conscious remain state-of-the-art methods to elicit functions of brain areas and define and personalize safe boundaries of tumor resection (18, 19).”
BackgroundStummer, W., Novotny, A., Stepp, H., Goetz, C., Bise, K., & Reulen, H. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.6.1003 · Cited by 881 · cited 1×
“Most studies on glioma surgery with 5-ALA fluorescence for guidance have documented increases in tumor resection area (109, 110).”
BackgroundWalter, S., Susanne, S., Simon, W., Herbert, S., Clemens, F., Claudia, G., Alwin, E. G., Rainer, K., & Hans, J. R. (1998) · Neurosurgery · doi:10.1097/00006123-199803000-00017 · Cited by 690
Shinoda, J., Yano, H., Yoshimura, S.-I., Okumura, A., Kaku, Y., Iwama, T., & Sakai, N. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.3.0597 · Cited by 249
Frameless neuronavigation in modern neurosurgery
Spetzger, U., Laborde, G., & Gilsbach, J. (1995) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2008-1053478 · Cited by 107
Cited by
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
Tumor treating fields increases membrane permeability in glioblastoma cells
Chang, E., Patel, C. B., Pohling, C., Young, C., Song, J., Flores, T. A., Zeng, Y., Joubert, L.-M., Arami, H., Natarajan, A., et al. (2018) · Cell Death Discovery · doi:10.1038/s41420-018-0130-x · Cited by 137
Visualization technologies for 5-ALA-based fluorescence-guided surgeries
Wei, L., Roberts, D. W., Sanai, N., & Liu, J. T. C. (2019) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-03077-9 · Cited by 67
Izadyyazdanabadi, M., Belykh, E., Mooney, M. A., Eschbacher, J. M., Nakaji, P., Yang, Y., & Preul, M. C. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00240 · Cited by 45
“While a wide range of fluorophores have been used for CLE in gastroenterology and other medical specialties, fluorophore options are limited for in vivo human brain use due to potential toxicity (8, 9, 11, 14).”
BackgroundSelf-citation
Metadata
- Authors
- Belykh, E., Martirosyan, N. L., Yagmurlu, K., Miller, E. J., Eschbacher, J. M., Izadyyazdanabadi, M., Bardonova, L. A., Byvaltsev, V. A., Nakaji, P., & Preul, M. C.
- Venue
- Frontiers in Surgery
- Publisher
- Frontiers Media SA
- Published
- 2016-10-17
- Volume
- 3
- Pages
- 55-55
- ISSN
- 2296-875X (ISSN-L)
- OpenAlex
- W2532626005
- Cited by
- 134
- References
- 11
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Fluorescence Imaging for Personalized Brain Tumor Resection: Current State and Future Directions. https://app.cochat.ai/papers/10.3389/fsurg.2016.00055
- The paper
- Belykh, E., Martirosyan, N. L., Yagmurlu, K., Miller, E. J., Eschbacher, J. M., Izadyyazdanabadi, M., Bardonova, L. A., Byvaltsev, V. A., Nakaji, P., & Preul, M. C. (2016). Intraoperative Fluorescence Imaging for Personalized Brain Tumor Resection: Current State and Future Directions. Frontiers in Surgery. https://doi.org/10.3389/fsurg.2016.00055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.