Electrochemical Biosensors Based on Conducting Polymers: A Review

Lakard, Boris · 2020 · Applied Sciences

Abstract

Conducting polymers are an important class of functional materials that has been widely applied to fabricate electrochemical biosensors, because of their interesting and tunable chemical, electrical, and structural properties. Conducting polymers can also be designed through chemical grafting of functional groups, nanostructured, or associated with other functional materials such as nanoparticles to provide tremendous improvements in sensitivity, selectivity, stability and reproducibility of the biosensor’s response to a variety of bioanalytes. Such biosensors are expected to play a growing and significant role in delivering the diagnostic information and therapy monitoring since they have advantages including their low cost and low detection limit. Therefore, this article starts with the description of electroanalytical methods (potentiometry, amperometry, conductometry, voltammetry, impedometry) used in electrochemical biosensors, and continues with a review of the recent advances in the application of conducting polymers in the recognition of bioanalytes leading to the development of enzyme based biosensors, immunosensors, DNA biosensors, and whole-cell biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app10186614

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 148

  1. Diaz, 1981, Electrochemical preparation and characterisation of conducting polymers, Chem. Scr., 17, 145
  2. Diaz, A.F., and Kanazawa, K.K. (1979). Electrochemical polymerisation of pyrrole. J. Chem. Soc. Chem. Commun., 635. · DOI
  3. Kanazawa, K.K., Diaz, A.F., Geiss, R.H., Gill, W.D., Kwak, J.F., and Logan, J.A. (1979). ‘Organic metals’: Polypyrrole a stable synthetic ‘metallic’ polymer. J. Chem. Soc. Chem. Commun., 854. · doi:10.1039/c39790000854
  4. Le, T.H., Kim, Y., and Yoon, H. (2017). Electrical and Electrochemical Properties of Conducting Polymers. Polymers, 9. · DOI · Paper page
  5. Tsukamoto, 1992, Recent advances in highly conductive polyacetylene, Adv. Phys., 41, 509, 10.1080/00018739200101543 · DOI
  6. Tsukamoto, 1990, Structure and electrical properties of polyacetylene yielding a conductivity of 105 S/cm, Jpn. J. Appl. Phys., 29, 125, 10.1143/JJAP.29.125 · doi:10.1143/jjap.29.125
  7. Patois, 2010, Effect of various parameters on the conductivity of free standing electrosynthesized polypyrrole films, Synth. Met., 160, 2180, 10.1016/j.synthmet.2010.08.005 · doi:10.1016/j.synthmet.2010.08.005
  8. Zhang, 2009, Controllable molecular doping and charge transport in solution-processed polymer semiconducting layers, Adv. Funct. Mater., 19, 1901, 10.1002/adfm.200801761 · doi:10.1002/adfm.200801761
  9. Ahlskog, 1997, The temperature dependence of the conductivity in the critical regime of the metal-insulator transition in conducting polymers, J. Phys. Condens. Matter, 9, 4145, 10.1088/0953-8984/9/20/014 · doi:10.1088/0953-8984/9/20/014
  10. Aleshin, 1997, Metallic conductivity at low temperatures in poly (3,4-ethylenedioxythiophene) doped with PF6, Phys. Rev. B, 56, 3659, 10.1103/PhysRevB.56.3659 · doi:10.1103/physrevb.56.3659
  11. Lee, 2006, Metallic transport in polyaniline, Nature, 441, 65, 10.1038/nature04705 · DOI · Paper page
  12. Wataru, 2002, Cyclic step-voltammetric analysis of cation-driven and anion-driven actuation in polypyrrole films, Jpn. J. Appl. Phys., 41, 7532, 10.1143/JJAP.41.7532 · doi:10.1143/jjap.41.7532
  13. Paul, 1985, Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices, J. Phys. Chem., 89, 1441, 10.1021/j100254a028 · DOI · Paper page
  14. Wan, M. (2008). Conducting Polymers with Micro or Nanometer Structure, Springer.
  15. Li, Y. (2015). Conducting polymer. Organic Optoelectronic Materials, Springer International Publishing. · DOI
  16. Bredas, 1981, Theoretical Studies of Charged Defect States in Doped Polyacetylene and Polyparaphenylene, Mol. Cryst. Liq. Cryst., 77, 319, 10.1080/00268948108075251 · doi:10.1080/00268948108075251
  17. Scrosati, 1988, Electrochemical Properties of Conducting Polymers, Prog. Solid State Chem., 18, 1, 10.1016/0079-6786(88)90007-6 · doi:10.1016/0079-6786(88)90007-6
  18. Beaujuge, 2010, Color Control in π—Conjugated Organic Polymers for Use in Electrochromic Devices, Chem. Rev., 110, 268, 10.1021/cr900129a · DOI · Paper page
  19. Bharti, 2018, Conductive Polymers for Thermoelectric Power Generation, Prog. Mater. Sci., 93, 270, 10.1016/j.pmatsci.2017.09.004 · DOI · Paper page
  20. Fan, 2019, Thermoelectric Properties of PEDOT: PSS, Adv. Electron. Mater., 5, 1800769, 10.1002/aelm.201800769 · DOI · Paper page
  21. Guerfi, 2014, High cycling stability of zinc-anode/conducting polymer rechargeable battery with non-aqueous electrolyte, J. Power Sources, 248, 1099, 10.1016/j.jpowsour.2013.09.082 · doi:10.1016/j.jpowsour.2013.09.082
  22. Katz, 2010, Batteries and Charge Storage Devices Based on Electronically Conducting Polymers, J. Mater. Res., 25, 1561, 10.1557/JMR.2010.0201 · doi:10.1557/jmr.2010.0201
  23. Ehsani, 2017, High performance electrochemical pseudocapacitors from ionic liquid assisted electrochemically synthesized p-type conductive polymer, J. Colloid Interface Sci., 490, 91, 10.1016/j.jcis.2016.11.024 · DOI
  24. Kao, 2011, Conducting-polymer-based supercapacitor devices and electrodes, J. Power Sources, 196, 1, 10.1016/j.jpowsour.2010.06.084 · DOI · Paper page
  25. Lee, 2016, Long-Term Stable Recombination Layer for Tandem Polymer Solar Cells Using Self-Doped Conducting Polymers, ACS Appl. Mater. Interfaces, 8, 6144, 10.1021/acsami.5b11742 · doi:10.1021/acsami.5b11742
  26. Mengistie, 2014, Highly conductive PEDOT: PSS treated with formic acid for ITO-free polymer solar cells, ACS Appl. Mater. Interfaces, 6, 2292, 10.1021/am405024d · DOI · Paper page
  27. Zhang, 2019, Electrochemically polymerized poly (3, 4-phenylenedioxythiophene) as efficient and transparent counter electrode for dye sensitized solar cells, Electrochim. Acta, 300, 482, 10.1016/j.electacta.2019.01.006 · DOI
  28. Boudreault, 2011, Processable Low-Bandgap Polymers for Photovoltaic Applications, Chem. Mater., 23, 456, 10.1021/cm1021855 · DOI · Paper page
  29. Kim, 2013, Achieving high efficiency and improved stability in ITO free transparent organic light-emitting diodes with conductive polymer electrodes, Adv. Funct. Mater., 23, 3763, 10.1002/adfm.201203449 · DOI
  30. Bhuvana, 2018, Polymer Light Emitting Diodes: Materials, Technology and Device, Polym. Plast. Technol. Eng., 57, 1784, 10.1080/03602559.2017.1422269 · doi:10.1080/03602559.2017.1422269
  31. Dutta, 2015, Enhancements of Catalyst Distribution and Functioning Upon Utilization of Conducting Polymers as Supporting Matrices in DMFCs: A Review, Polym. Rev., 55, 1, 10.1080/15583724.2014.958771 · DOI
  32. Baldissera, 2010, Electrochemical impedance spectroscopy investigation of chlorinated rubber-based coatings containing polyaniline as anticorrosion agent, Mater. Corros., 61, 790, 10.1002/maco.200905254 · doi:10.1002/maco.200905254
  33. Deshpande, 2014, Conducting polymers for corrosion protection: A review, J. Coat. Techn. Res., 11, 473, 10.1007/s11998-014-9586-7 · DOI · Paper page
  34. Soganci, 2018, Synthesis of highly branched conducting polymer architecture for electrochromic applications, Polymer, 134, 187, 10.1016/j.polymer.2017.11.067 · doi:10.1016/j.polymer.2017.11.067
  35. Topart, 2001, Wide band electrochromic displays based on thin conducting polymer films, Electrochim. Acta, 46, 2137, 10.1016/S0013-4686(01)00392-9 · doi:10.1016/s0013-4686(01)00392-9
  36. Barnes, 1998, Towards a ‘smart window’ for microwave applications, Smart Mater. Struct., 7, 752, 10.1088/0964-1726/7/6/003 · doi:10.1088/0964-1726/7/6/003
  37. Barus, 2018, Effect of Chemical Treatment on Conducting Polymer for Flexible Smart Window Application, J. Phys. Conf. Ser., 1116, 032006, 10.1088/1742-6596/1116/3/032006 · doi:10.1088/1742-6596/1116/3/032006
  38. Wang, 2017, CVD Polymers for Devices and Device Fabrication, Adv. Mater., 29, 1604606, 10.1002/adma.201604606 · doi:10.1002/adma.201604606
  39. Park, C.S., Kim, D.H., Shin, B.J., and Tae, H.S. (2016). Synthesis and Characterization of Nanofibrous Polyaniline Thin Film Prepared by Novel Atmospheric Pressure Plasma Polymerization Technique. Materials, 9. · doi:10.3390/ma9010039
  40. Liu, 2017, Plasma polymerization of poly (3,4-ethylenedioxyethene) films: The influence of plasma gas phase chemistry, J. Vac. Sci. Technol. A, 35, 021302, 10.1116/1.4968017 · doi:10.1116/1.4968017
  41. Loewe, 2001, Regioregular, Head-to-Tail Coupled Poly(3-Alkylthiophenes) Made Easy by the GRIM Method: Investigation of the Reaction and the Origin of Regioselectivity, Macromolecules, 34, 4324, 10.1021/ma001677+ · DOI
  42. Tamba, 2013, Synthesis of High-Molecular-Weight Head-to-Tail-Type Poly(3-Substituted-Thiophene)s by Cross-Coupling Polycondensation with [CpNiCl(NHC)] as a Catalyst, Chem. Lett., 42, 281, 10.1246/cl.2013.281 · doi:10.1246/cl.2013.281
  43. Malinauskas, 2001, Chemical deposition of conducting polymers, Polymer, 42, 3957, 10.1016/S0032-3861(00)00800-4 · DOI · Paper page
  44. Erdem, 2004, The chemical synthesis of conductive polyaniline doped with dicarboxylic acids, Eur. Polym. J., 40, 785, 10.1016/j.eurpolymj.2003.12.007 · doi:10.1016/j.eurpolymj.2003.12.007
  45. Ramanavicius, 2005, Polypyrrole-coated glucose oxidase nanoparticles for biosensor design, Sens. Actuators B, 111, 532, 10.1016/j.snb.2005.03.038 · DOI
  46. Jha, 2011, Growth of Free-Standing Polypyrrole Nanosheets at Air/Liquid Interface Using J-Aggregate of Porphyrin Derivative as in-Situ Template, Macromolecules, 44, 4583, 10.1021/ma2002849 · doi:10.1021/ma2002849
  47. Heinze, 2010, Electrochemistry of Conducting Polymers—Persistent Models and New Concepts, Chem. Rev., 110, 4724, 10.1021/cr900226k · DOI · Paper page
  48. Park, Y., Jung, J., and Chang, M. (2019). Research Progress on Conducting Polymer-Based Biomedical Applications. Appl. Sci., 9. · DOI
  49. Nair, 2019, Recent progress in conductive polymeric materials for biomedical applications, Polym. Adv. Technol., 30, 2932, 10.1002/pat.4725 · DOI
  50. Geetha, 2006, Biosensing and drug delivery by polypyrrole, Anal. Chim. Acta, 568, 119, 10.1016/j.aca.2005.10.011 · doi:10.1016/j.aca.2005.10.011
  51. Boehler, 2019, Tuning drug delivery from conducting polymer films for accurately controlled release of charged molecules, J. Control. Release, 304, 173, 10.1016/j.jconrel.2019.05.017 · DOI
  52. Krukiewicz, 2016, EQCM verification of the concept of drug immobilization and release from conducting polymer matrix, Electrochim. Acta, 212, 694, 10.1016/j.electacta.2016.07.055 · DOI
  53. Guo, 2018, Conducting polymers for tissue engineering, Biomacromolecules, 19, 1764, 10.1021/acs.biomac.8b00276 · DOI · Paper page
  54. Dong, 2020, Conductive biomaterials for muscle tissue engineering, Biomaterials, 229, 119584, 10.1016/j.biomaterials.2019.119584 · DOI · Paper page
  55. Zarrintai, 2018, Oligoaniline-based conductive biomaterials for tissue engineering, Acta Biomater., 72, 16, 10.1016/j.actbio.2018.03.042 · DOI
  56. Inal, 2017, Conducting polymer scaffolds for hosting and monitoring 3D cell culture, Adv. Biosyst., 1, 1700052, 10.1002/adbi.201700052 · DOI
  57. Lakard, 2007, Synthesis of polymer materials for use as cell culture substrates, Electrochim. Acta, 53, 1114, 10.1016/j.electacta.2007.04.098 · DOI
  58. Ateh, 2006, Polypyrrole-based conducting polymers and interactions with biological tissues, J. R. Soc. Interface, 3, 741, 10.1098/rsif.2006.0141 · DOI · Paper page
  59. He, 2019, Biocompatible conductive polymers with high conductivity and high stretchability, ACS Appl. Mater. Interfaces, 11, 26185, 10.1021/acsami.9b07325 · DOI · Paper page
  60. Humpolicek, 2018, The biocompatibility of polyaniline and polypyrrole: A comparative study of their cytotoxicity, embryotoxicity and impurity profile, Mat. Sci. Eng. C, 91, 303, 10.1016/j.msec.2018.05.037 · DOI
  61. Humpolicek, 2012, Biocompatibility of polyaniline, Synth. Met., 162, 722, 10.1016/j.synthmet.2012.02.024 · DOI · Paper page
  62. George, 2005, Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics, Biomaterials, 26, 3511, 10.1016/j.biomaterials.2004.09.037 · DOI · Paper page
  63. Kim, 2016, Disposable all-solid-state pH and glucose sensors based on conductivepolymer covered hierarchical AuZn oxide, Biosens. Bioelectron., 79, 165, 10.1016/j.bios.2015.12.002 · DOI
  64. Tuncagil, 2011, Gold nanoparticle modified conducting polymer of 4-(2,5-di(thiophen-2-yl)-1H-pyrrole-1-l) benzenamine for potential use as a biosensing material, Food Chem., 127, 1317, 10.1016/j.foodchem.2011.01.089 · doi:10.1016/j.foodchem.2011.01.089
  65. Glumbokaite, 2018, An Amperometric Glucose Biosensor Based on Poly (Pyrrole-2-Carboxylic Acid)/Glucose Oxidase Biocomposite, Electroanalysis, 30, 1642, 10.1002/elan.201800044 · DOI
  66. Gaikwad, 2006, Immobilization of GOD on electrochemically synthesized PANI film by cross-linking via glutaraldehyde for determination of glucose, Int. J. Electrochem. Sci., 1, 425, 10.1016/S1452-3981(23)17170-7 · doi:10.1016/s1452-3981(23)17170-7
  67. Lakard, 2004, Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films, Biosens. Bioelectron., 19, 1641, 10.1016/j.bios.2003.12.035 · DOI
  68. Magnin, 2008, Functionalization of Magnetic Nanowires by Charged Biopolymers, Biomacromolecules, 9, 2517, 10.1021/bm8005402 · doi:10.1021/bm8005402
  69. Xue, 2001, Polyaniline-polyisoprene composite film based glucose biosensor with high permselectivity, Synth. Met., 124, 345, 10.1016/S0379-6779(01)00381-2 · doi:10.1016/s0379-6779(01)00381-2
  70. Molino, 2012, Fibronectin and bovine serum albumin adsorption and conformational dynamics on inherently conducting polymers: A QCM-D study, Langmuir, 28, 8433, 10.1021/la300692y · DOI · Paper page
  71. Lakard, 2011, Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline, Biosens. Bioelectron., 26, 4139, 10.1016/j.bios.2011.04.009 · doi:10.1016/j.bios.2011.04.009
  72. Yang, 2014, High performance conducting polymer nanofiber biosensors for detection of biomolecules, Adv. Mater., 26, 4954, 10.1002/adma.201400753 · DOI
  73. Soares, 2012, Amperometric urea biosensors based on the entrapment of urease in polypyrrole films, React. Funct. Polym., 72, 148, 10.1016/j.reactfunctpolym.2011.12.002 · doi:10.1016/j.reactfunctpolym.2011.12.002
  74. Minett, 2002, Immobilisation of anti-Listeria in a polypyrrole film, React. Funct. Polym., 53, 217, 10.1016/S1381-5148(02)00175-X · DOI
  75. Mandli, 2018, Impedimetric genosensor for miRNA-34a detection in cell lysates using polypyrrole, J. Solid State Electrochem., 22, 1007, 10.1007/s10008-017-3819-5 · DOI
  76. Ramanavicius, 2006, Electrochemical sensors based on conducting polymer- polypyrrole, Electrochim. Acta, 51, 6025, 10.1016/j.electacta.2005.11.052 · doi:10.1016/j.electacta.2005.11.052
  77. Adeloju, 2001, Fabrication of ultra-thin polypyrrole–glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose, Biosens. Bioelectron., 16, 133, 10.1016/S0956-5663(00)00117-2 · DOI
  78. Leite, 2017, Use of sinusoidal voltages with fixed frequency in the preparation of tyrosinase based electrochemical biosensors for dopamineelectroanalysis, Sens. Actuators B, 240, 801, 10.1016/j.snb.2016.09.045 · DOI
  79. Clark, 1956, Monitor and control of blood and tissue oxygen tensions, Trans. Am. Soc. Artif. Intern. Organs, 2, 41
  80. Forzani, 2004, A Conducting Polymer Nanojunction Sensor for Glucose Detection, Nano Lett., 4, 1785, 10.1021/nl049080l · DOI · Paper page
  81. Chauhan, 2017, An electrochemical sensor for detection of neurotransmitter-acetylcholine using metal nanoparticles, 2D material and conducting polymer modified electrode, Biosens. Bioelectron., 89, 377, 10.1016/j.bios.2016.06.047 · DOI · Paper page
  82. Uwaya, 2020, Electrochemical detection of serotonin in banana at green mediated PPy/Fe3O4 NPs nanocomposites modified electrodes, Sens. Bio Sens. Res., 28, 100338, 10.1016/j.sbsr.2020.100338 · DOI
  83. Hamid, 2018, Electrochemical Preparation and Electrical Characterization of Polyaniline as a Sensitive Biosensor, Microsyst. Technol., 24, 1775, 10.1007/s00542-018-3793-6 · doi:10.1007/s00542-018-3793-6
  84. Bahadir, 2016, A review on impedimetric biosensors, Artif. Cells Nanomed Biotechn., 44, 248, 10.3109/21691401.2014.942456 · DOI · Paper page
  85. He, S., Yuan, Y., Nag, A., Feng, S., Afsarimanesh, N., Han, T., Mukhopadhyay, S.C., and Organ, D.R. (2020). A Review on the Use of Impedimetric Sensors for the Inspection of Food Quality. Int. J. Environ. Res. Public Health, 17. · DOI
  86. Peyman, 2020, A review on impedimetric immunosensors for pathogen and biomarker detection, Med. Microbiol. Immunol., 209, 343, 10.1007/s00430-020-00668-0 · DOI · Paper page
  87. Grant, 2005, Label-free and reversible immunosensor based upon an ac impedance interrogation protocol, Anal. Chim. Acta, 537, 163, 10.1016/j.aca.2005.01.003 · DOI
  88. Aydin, 2018, Highly sensitive electrochemical immunosensor based on polythiophene polymer with densely populated carboxyl groups as immobilization matrix for detection of interleukin 1β in human serum and saliva, Sens. Actuators B, 270, 18, 10.1016/j.snb.2018.05.014 · DOI
  89. Taleat, 2013, CA 125 Immunosensor Based on Poly-Anthranilic Acid Modified Screen-Printed Electrodes, Electroanalysis, 25, 269, 10.1002/elan.201200425 · DOI
  90. Jugovic, 2016, Polypyrrole-based Enzyme Electrode with Immobilized Glucose Oxidase for Electrochemical Determination of Glucose, Int. J. Electrochem. Sci., 11, 1152, 10.1016/S1452-3981(23)15912-8 · DOI
  91. Gvozdenovic, 2011, Electrochemical determination of glucose using polyaniline electrode modified by glucose oxidase, Food Chem., 124, 396, 10.1016/j.foodchem.2010.06.046 · doi:10.1016/j.foodchem.2010.06.046
  92. Lai, 2016, Polyaniline-based glucose biosensor: A review, J. Electroanal. Chem., 782, 138, 10.1016/j.jelechem.2016.10.033 · DOI · Paper page
  93. Singh, 2009, Polypyrrole based amperometric glucose biosensors, Sens. Actuators B, 143, 430, 10.1016/j.snb.2009.09.005 · doi:10.1016/j.snb.2009.09.005
  94. Lau, 2003, Disposable glucose sensors for flow injection analysis using substituted 1,4-benzoquinonemediators, Electroanalysis, 15, 975, 10.1002/elan.200390118 · doi:10.1002/elan.200390118
  95. Qiu, 2009, Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose, Anal. Biochem., 385, 264, 10.1016/j.ab.2008.12.002 · doi:10.1016/j.ab.2008.12.002
  96. Jian, 2011, An amperometric glucose biosensor based on a screen-printed electrode and Os-complex mediator for flow injection analysis, Measurement, 44, 1878, 10.1016/j.measurement.2011.09.001 · doi:10.1016/j.measurement.2011.09.001
  97. Shrestha, 2016, High-performance glucose biosensor based on chitosane-glucose oxidase immobilized polypyrrole/Nafion/functionalized multi-walled carbon nanotubes bio-nanohybrid film, J. Colloid Interf. Sci., 482, 39, 10.1016/j.jcis.2016.07.067 · DOI
  98. Shrestha, 2017, Globular Shaped Polypyrrole Doped Well-Dispersed Functionalized Multiwall Carbon Nanotubes/Nafion Composite for Enzymatic Glucose Biosensor Application, Sci. Rep., 7, 16191, 10.1038/s41598-017-16541-9 · DOI
  99. Chen, 2012, Glucose biosensor based on three dimensional ordered macroporous self-doped polyaniline/Prussian blue bicomponent film, Anal. Chim. Acta, 723, 94, 10.1016/j.aca.2012.02.032 · DOI
  100. Chowdhury, 2014, Highly sensitive electrochemical biosensor for glucose, DNA and protein using gold-polyaniline nanocomposites as a common matrix, Sens. Actuators B, 190, 348, 10.1016/j.snb.2013.08.071 · doi:10.1016/j.snb.2013.08.071
  101. Mazeiko, 2013, Gold Nanoparticle and Conducting Polymer—Polyaniline—Based Nanocomposites for Glucose Biosensor Design, Sens. Actuators B, 189, 187, 10.1016/j.snb.2013.03.140 · DOI
  102. Zhai, 2013, Highly sensitive glucose sensor based on Pt nanoparticle/polyaniline hydrogel heterostructures, ACS Nano, 7, 3540, 10.1021/nn400482d · DOI · Paper page
  103. Zhong, 2011, In situ chemo-synthesized multi-wall carbon nanotube-conductive polyaniline nanocomposites: Characterization and application for a glucose amperometric biosensor, Talanta, 85, 104, 10.1016/j.talanta.2011.03.040 · DOI
  104. Jimenez-Fierrez, F., Gonzalez-Sanchez, M.I., Jimenez-Perez, R., Iniesta, J., and Valero, E. (2020). Glucose Biosensor Based on Disposable Activated Carbon Electrodes Modified with Platinum Nanoparticles Electrodeposited on Poly(Azure A). Sensors, 20. · DOI
  105. Djaalab, E., El Hadi Samar, M., Zougar, S., and Kherrat, R. (2018). Electrochemical Biosensor for the Determination of Amlodipine Besylate Based on Gelatin-Polyaniline Iron Oxide Biocomposite Film. Catalysts, 8. · doi:10.3390/catal8060233
  106. Zhuang, 2016, One-step electrochemical fabrication of a nickel oxide nanoparticle/polyaniline nanowire/graphene oxide hybrid on a glassy carbon electrode for use as a non-enzymatic glucose biosensor, RSC Adv., 6, 92541, 10.1039/C6RA14970G · doi:10.1039/c6ra14970g
  107. Wang, 2009, Detection of Glucose Based on Direct Electron Transfer Reaction of Glucose Oxidase Immobilized on Highly Ordered Polyaniline Nanotubes, Anal. Chem., 81, 1638, 10.1021/ac802421h · DOI · Paper page
  108. Xu, 2012, Modification of polypyrrole nanowires array with platinum nanoparticles and glucose oxidase for fabrication of a novel glucose biosensor, Anal. Chim. Acta, 755, 100, 10.1016/j.aca.2012.09.037 · doi:10.1016/j.aca.2012.09.037
  109. Komathi, 2017, Polyaniline nanoflowers grafted onto nanodiamonds via a soft template-guided secondary nucleation process for high-performance glucose sensing, RSC Adv., 7, 15342, 10.1039/C6RA24760A · DOI
  110. Ramanavicius, 1999, Polypyrrole-Entrapped Quinohemoprotein Alcohol Dehydrogenase. Evidence for Direct Electron Transfer via Conducting-Polymer Chains, Anal. Chem., 71, 3581, 10.1021/ac981201c · DOI
  111. Bollela, P., Gorton, L., and Antiochia, R. (2018). Direct Electron Transfer of Dehydrogenases for Development of 3rd Generation Biosensors and Enzymatic Fuel Cells. Sensors, 18. · DOI
  112. Oztekin, 2011, Direct electron transfer from glucose oxidase immobilized on polyphenanthroline-modified glassy carbon electrode, Biosens. Bioelectron., 26, 2541, 10.1016/j.bios.2010.11.001 · doi:10.1016/j.bios.2010.11.001
  113. Bagdziunas, G., and Palinauskas, D. (2020). Poly (9H-carbazole) as a Organic Semiconductor for Enzymatic and Non-Enzymatic Glucose Sensors. Biosensors, 10. · doi:10.3390/bios10090104
  114. Grennan, 2003, Atrazine analysis using an amperometric immunosensor based on single-chain antibody fragments and regeneration-free multi-calibrant measurement, Anal. Chim. Acta, 500, 287, 10.1016/S0003-2670(03)00942-5 · DOI
  115. Darain, 2004, Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy, Biosens. Bioelectron., 19, 1245, 10.1016/j.bios.2003.11.014 · doi:10.1016/j.bios.2003.11.014
  116. Wang, 2018, A cascade reaction signal-amplified amperometric immunosensor platform for ultrasensitive detection of tumour marker, Sens. Actuators B, 254, 642, 10.1016/j.snb.2017.07.135 · DOI
  117. Zhao, 2018, Facile Synthesis of Polyaniline-Polythionine Redox Hydrogel: Conductive, Antifouling and Enzyme-Linked Material for Ultrasensitive Label-Free Amperometric Immunosensor toward Carcinoma Antigen-125, Anal. Chim. Acta, 997, 60, 10.1016/j.aca.2017.10.017 · DOI
  118. Shaikh, M.O., Srikanth, B., Zhu, P.Y., and Chuang, C.H. (2019). Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease. Sensors, 19. · DOI
  119. Liu, 2018, Enhanced Electrochemical Biosensing of Alpha-Fetoprotein Based on Three-Dimensional Macroporous Conducting Polymer Polyaniline, Sens. Actuators B, 255, 2568, 10.1016/j.snb.2017.09.062 · doi:10.1016/j.snb.2017.09.062
  120. Dutta, 2018, Development of an effective electrochemical platform for highly sensitive DNA detection using MoS2—polyaniline nanocomposites, Biochem. Eng. J., 140, 130, 10.1016/j.bej.2018.09.016 · DOI
  121. Eguiluz, 2009, Sequence-specific electrochemical detection of Alicyclobacillus acidoterrestris DNA using electroconductive polymer-modified fluorine tin oxide electrodes, Analyst, 134, 314, 10.1039/B809080G · doi:10.1039/b809080g
  122. Tlili, 2008, Direct electrochemical probing of DNA hybridization on oligonucleotide-functionalized polypyrrole, Mater. Sci. Eng. C, 28, 848, 10.1016/j.msec.2007.10.061 · doi:10.1016/j.msec.2007.10.061
  123. Wilson, 2012, Polypyrrole-polyaniline-Au (PPy-PANi-Au) nano composite films for label-free electrochemical DNA sensing, Sens. Actuators B, 171, 216, 10.1016/j.snb.2012.03.019 · doi:10.1016/j.snb.2012.03.019
  124. Radhakrishnan, 2013, Polypyrrole-poly (3,4-ethylenedioxythiophene)-Ag (PPy-PEDOT-Ag) nanocomposite films for label-free electrochemical DNA sensing, Biosens. Bioelectron., 47, 133, 10.1016/j.bios.2013.02.049 · doi:10.1016/j.bios.2013.02.049
  125. Xu, 2006, Impedance DNA biosensor using electropolymerized polypyrrole/multiwalled carbon nanotubes modified electrode, Electroanalysis, 18, 1471, 10.1002/elan.200603544 · DOI
  126. Chang, 2007, Electrochemical DNA biosensor based on conducting polyaniline nanotube Array, Anal. Chem., 79, 5111, 10.1021/ac070639m · doi:10.1021/ac070639m
  127. Zhu, 2006, Electrochemically fabricated polyaniline nanowire-modified electrode for voltammetric detection of DNA hybridization, Electrochim. Acta, 51, 3758, 10.1016/j.electacta.2005.10.038 · DOI
  128. Du, 2012, Fabrication of DNA/graphene/polyaniline nanocomplex for label-free voltammetric detection of DNA hybridization, Talanta, 88, 439, 10.1016/j.talanta.2011.10.054 · DOI
  129. Mohamad, F.S., Zaid, M.H.M., Abdullah, J., Zawawi, R.M., Lim, H.N., Sulaiman, Y., and Rahman, N.A. (2017). Synthesis and Characterization of Polyaniline/Graphene Composite Nanofiber and Its Application as an Electrochemical DNA Biosensor for the Detection of Mycobacterium tuberculosis. Sensors, 17. · doi:10.3390/s17122789
  130. Ding, 2008, Trends in Cell-Based Electrochemical Biosensors, Curr. Med. Chem., 15, 3160, 10.2174/092986708786848514 · DOI
  131. Wei, 2017, Directing Stem Cell Differentiation via Electrochemical Reversible Switching between Nanotubes and Nanotips of Polypyrrole Array, ACS Nano, 11, 5915, 10.1021/acsnano.7b01661 · DOI
  132. Lakard, 2009, Effect of ultrasounds on the electrochemical synthesis of polypyrrole. Application to the adhesion and growth of biological cells, Bioelectrochemistry, 75, 148, 10.1016/j.bioelechem.2009.03.010 · DOI
  133. Yea, 2009, Ultrathin polyaniline film coated on an indium-tin oxide cell-based chip for study of anticancer effect, Thin Solid Film, 518, 661, 10.1016/j.tsf.2009.07.062 · doi:10.1016/j.tsf.2009.07.062
  134. Lee, 2009, Neuroactive conducting scaffolds: Nerve growth factor conjugation on active ester-functionalized polypyrrole, J. R. Soc. Interface, 6, 801, 10.1098/rsif.2008.0403 · DOI
  135. Chen, 2006, Vertically Aligned Carbon Nanofiber Arrays: An Advance toward Electrical-Neural Interfaces, Small, 2, 89, 10.1002/smll.200500175 · DOI · Paper page
  136. Yea, 2010, Analysis of effect of nanoporous alumina substrate coated with polypyrrole nanowire on cell morphology based on AFM topography, Ultramicroscopy, 110, 676, 10.1016/j.ultramic.2010.02.031 · doi:10.1016/j.ultramic.2010.02.031
  137. Apetrei, 2017, Glucose biosensor based on whole cells of Aspergillus niger MIUG 34 coated with polypyrrole, J. Biotechnol., 256, S55, 10.1016/j.jbiotec.2017.06.987 · doi:10.1016/j.jbiotec.2017.06.987
  138. Cevik, 2019, Electrochemical Glucose Biosensors: Whole Cell Microbial and Enzymatic Determination based on 10-(4H-dithiyeno [3,2-b:2′,3′-d]pyroll-4-il) decan-1-amine Interfaces Glassy Carbon Electrodes, Anal. Lett., 52, 1138, 10.1080/00032719.2018.1521828 · DOI
  139. Baskurt, 2012, A conducting polymer with benzothiadiazole unit: Cell based biosensing applications and adhesion properties, Colloids Surf. B, 97, 13, 10.1016/j.colsurfb.2012.04.005 · doi:10.1016/j.colsurfb.2012.04.005
  140. Guler, 2014, A novel functional conducting polymer as an immobilization platform, Mat. Sci. Eng. C, 40, 148, 10.1016/j.msec.2014.03.063 · doi:10.1016/j.msec.2014.03.063
  141. Tuncagil, 2009, Design of a microbial sensor using conducting polymer of 4-(2,5-di(thiophen-2-yl)-1H-pyrrole-1-l) benzenamine, Sens. Actuators B, 137, 42, 10.1016/j.snb.2008.10.067 · doi:10.1016/j.snb.2008.10.067
  142. Jha, 2009, Entrapment of live microbial cells in electropolymerized polyaniline and their use as urea biosensor, Biosens. Bioelectron., 24, 2637, 10.1016/j.bios.2009.01.024 · DOI
  143. Ratautaite, 2015, Characterization of caffeine-imprinted polypyrrole by a quartz crystalmicrobalance and electrochemical impedance spectroscopy, Sens. Actuators B, 212, 63, 10.1016/j.snb.2015.01.109 · doi:10.1016/j.snb.2015.01.109
  144. Xing, 2012, Electrochemical sensor based on molecularly imprinted film at polypyrrole-sulfonated graphene/hyaluronic acid-multiwalled carbon nanotubes modified electrode for determination of tryptamine, Biosens. Bioelectron., 31, 277, 10.1016/j.bios.2011.10.032 · DOI · Paper page
  145. Zhou, 2012, A multiporous electrochemical sensor for epinephrine recognition and detection based on molecularly imprinted polypyrrole, RSC Advances, 2, 7803, 10.1039/c2ra20787g · DOI
  146. Radi, 2014, Determination of coccidiostat clopidol on an electropolymerized-molecularly imprinted polypyrrole polymer modified screen printed carbon electrode, Anal. Methods, 6, 7967, 10.1039/C4AY01320D · doi:10.1039/c4ay01320d
  147. Lai, 2019, A novel alpha-fetoprotein-MIP immunosensor based on AuNPs/PTh modified glass carbon electrode, Chin. Chem. Lett., 30, 160, 10.1016/j.cclet.2018.07.011 · DOI
  148. Karami, 2019, Dual-modality impedimetric immunosensor for early detection of prostate-specific antigen and myoglobin markers based on antibody-molecularly imprinted polymer, Talanta, 202, 111, 10.1016/j.talanta.2019.04.061 · doi:10.1016/j.talanta.2019.04.061

Cited by

See all 203

Metadata

Authors
Lakard, B.
Venue
Applied Sciences
Publisher
MDPI AG
Published
2020-09-22
Volume
10
Issue
18
Pages
6614
ISSN
2076-3417
Cited by
203
References
3
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical Biosensors Based on Conducting Polymers: A Review. https://app.cochat.ai/papers/10.3390/app10186614
The paper
Lakard, B. (2020). Electrochemical Biosensors Based on Conducting Polymers: A Review. Applied Sciences. https://doi.org/10.3390/app10186614

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.