Intra-Reliability of a Wearable Near-Infrared Sensor for Monitoring the Intensity of Exercise
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The Q-LAC analyzer, a portable device employing near-infrared spectroscopy (NIRS), was designed to measure muscle oxygen saturation (SmO2) during physical exercise. This study aimed to assess the reliability of the Q-LAC analyzer in determining SmO2 levels during incremental cycling exercise. Thirteen physically active males (age 28.1 ± 5.3 y; height 181.2 ± 5.7 cm; body mass 79.9 ± 11.1 kg; BMI 24.2 ± 2.4 kg/m2) participated in this study. A submaximal incremental exercise test (SIET) on an electromagnetic cycle ergometer with a seven-day interval was performed twice. SmO2 levels in the vastus lateralis (VL) muscle of the dominant leg were simultaneously recorded using the Q-LAC device during both tests. The study calculated the intraclass correlation coefficient (ICC), the coefficient of variation (CV), the standard error of measurement (SEM), the smallest worthwhile change (SWC), and mean detectable change (MDC). A within-within-subjects ANOVA revealed no statistically significant effects for session (F1,12 = 0.97, p = 0.34, η2 = 0.07) and the interaction between session and workload (F4,48 = 0.19, p = 0.94, η2 = 0.02). ICC values ranged from 0.72 to 0.91. Furthermore, the analysis of CV, SEM, and SWC indicated that SmO2 measurements obtained with the Q-LAC device exhibit good reliability but marginal sensitivity. In conclusion, the portable Q-LAC analyzer provides consistent measurements of muscle oxygen saturation during low-to-moderate-intensity exercise on a cycle ergometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“State-of-the-art NIRS devices typically involve a small wearable sensor, that transmits data wirelessly to a sports watch or smartphone app [43].”
From Transferability of Exercise Intensity Based on Muscle Oxygenation from Normoxia to Hypoxia in Ski-Mountaineering Athletes—Exploratory Study (2024) · cites this paper as [43]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Eta squared and partial eta squared as measures of effect size in educational research
Richardson, J. T. E. (2011) · Educational Research Review · doi:10.1016/j.edurev.2010.12.001 · Cited by 3,465
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 366
Beltz, N. M., Gibson, A. L., Janot, J. M., Kravitz, L., Mermier, C. M., & Dalleck, L. C. (2016) · Journal of Sports Medicine · doi:10.1155/2016/3968393 · Cited by 306
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Research works printed but not linked: 2
- Hopkins, W. Spreadsheets for Analysis of Validity and Reliability (Excel Spreadsheet). Internet Soc. Sport Sci. 2015, 19, 36-42. Available online: https://www.sportsci.org/resource/stats/xrely.xls (accessed on 25 June 2024).
- Buchheit, M. Magnitudes matter more than beetroot juice. Sport Perform. Sci. Rep. 2015, 15, 1-3.
Cited by
Rębiś, K., Kowalski, T., Michalik, K., & Klusiewicz, A. (2024) · Sports · doi:10.3390/sports12120351 · Cited by 4
Self-citationBaker, P. A., Ladan, A. N., Joniak, K. E., Moore, S. R., Britton, M. E., Cantu, E. I., Jenkins, N. D. M., & Smith‐Ryan, A. E. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0397 · Cited by 1
Caulier‐Cisterna, R., Vega‐Moraga, A., Ramos‐López, D., & Briceño, F. A. C. (2026) · Medical Sciences · doi:10.3390/medsci14020317
Metadata
- Authors
- Michalik, K., Smolarek, M., Nowak, M., Pueo, B., & Żmijewski, P.
- Affiliations
- Wroclaw University of Health and Sport Sciences (PL)
- Jan Długosz University (PL)
- Research Group in Health, Physical Activity, and Sports Technology (Health-Tech), Faculty of Education, University of Alicante, 03690 San Vicente del Raspeig, Spain
- Gdansk University of Physical Education and Sport (PL)
- Corresponding author
- Żmijewski, Piotr
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2024-07-04
- Volume
- 14
- Issue
- 13
- Pages
- 5856
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W4400363928
- Semantic Scholar
- c2b4f1f6c7af584c573a371490274306947ad7e7
- Cited by
- 3
- References
- 32
- Citations by year
- 2026: 2 · 2024: 1
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Applied Sciences (publishedVersion, cc-by)
- RUA, Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- near-infrared spectroscopy, muscle oxygen saturation, wearable sensors, exercise intensity monitoring, incremental cycling exercise, vastus lateralis, measurement reliability, smallest worthwhile change, cycle ergometer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.