CoChat

Intra-Reliability of a Wearable Near-Infrared Sensor for Monitoring the Intensity of Exercise

Open access
Michalik, Kamil, Smolarek, Marcin, Nowak, Michał, Pueo, Basilio, Żmijewski, Piotr · 2024 · Applied Sciences

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

The Q-LAC analyzer, a portable device employing near-infrared spectroscopy (NIRS), was designed to measure muscle oxygen saturation (SmO2) during physical exercise. This study aimed to assess the reliability of the Q-LAC analyzer in determining SmO2 levels during incremental cycling exercise. Thirteen physically active males (age 28.1 ± 5.3 y; height 181.2 ± 5.7 cm; body mass 79.9 ± 11.1 kg; BMI 24.2 ± 2.4 kg/m2) participated in this study. A submaximal incremental exercise test (SIET) on an electromagnetic cycle ergometer with a seven-day interval was performed twice. SmO2 levels in the vastus lateralis (VL) muscle of the dominant leg were simultaneously recorded using the Q-LAC device during both tests. The study calculated the intraclass correlation coefficient (ICC), the coefficient of variation (CV), the standard error of measurement (SEM), the smallest worthwhile change (SWC), and mean detectable change (MDC). A within-within-subjects ANOVA revealed no statistically significant effects for session (F1,12 = 0.97, p = 0.34, η2 = 0.07) and the interaction between session and workload (F4,48 = 0.19, p = 0.94, η2 = 0.02). ICC values ranged from 0.72 to 0.91. Furthermore, the analysis of CV, SEM, and SWC indicated that SmO2 measurements obtained with the Q-LAC device exhibit good reliability but marginal sensitivity. In conclusion, the portable Q-LAC analyzer provides consistent measurements of muscle oxygen saturation during low-to-moderate-intensity exercise on a cycle ergometer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app14135856

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 2

  1. Hopkins, W. Spreadsheets for Analysis of Validity and Reliability (Excel Spreadsheet). Internet Soc. Sport Sci. 2015, 19, 36-42. Available online: https://www.sportsci.org/resource/stats/xrely.xls (accessed on 25 June 2024).
  2. Buchheit, M. Magnitudes matter more than beetroot juice. Sport Perform. Sci. Rep. 2015, 15, 1-3.

Cited by

See all 3

Metadata

Authors
Michalik, K., Smolarek, M., Nowak, M., Pueo, B., & Żmijewski, P.
Affiliations
  • Wroclaw University of Health and Sport Sciences (PL)
  • Jan Długosz University (PL)
  • Research Group in Health, Physical Activity, and Sports Technology (Health-Tech), Faculty of Education, University of Alicante, 03690 San Vicente del Raspeig, Spain
  • Gdansk University of Physical Education and Sport (PL)
Corresponding author
Żmijewski, Piotr
Venue
Applied Sciences
Publisher
MDPI AG
Published
2024-07-04
Volume
14
Issue
13
Pages
5856
ISSN
2076-3417 (ISSN-L)
OpenAlex
W4400363928
Cited by
3
References
32
Citations by year
2026: 2 · 2024: 1
FWCI
1.49
Type
journal article
Language
en
Open access
Locations
  • Applied Sciences (publishedVersion, cc-by)
  • RUA, Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
near-infrared spectroscopy, muscle oxygen saturation, wearable sensors, exercise intensity monitoring, incremental cycling exercise, vastus lateralis, measurement reliability, smallest worthwhile change, cycle ergometer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.