CoChat

Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring

Open access
Rösner, Laura, Walter, Franziska, Ude, Christian, John, Gernot, Beutel, Sascha · 2022 · Bioengineering

The DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.

Abstract

In recent years, the bioprocessing industry has experienced significant growth and is increasingly emerging as an important economic sector. Here, efficient process management and constant control of cellular growth are essential. Good product quality and yield can only be guaranteed with high cell density and high viability. Whereas the on-line measurement of physical and chemical process parameters has been common practice for many years, the on-line determination of viability remains a challenge and few commercial on-line measurement methods have been developed to date for determining viability in industrial bioprocesses. Thus, numerous studies have recently been conducted to develop sensors for on-line viability estimation, especially in the field of optical spectroscopic sensors, which will be the focus of this review. Spectroscopic sensors are versatile, on-line and mostly non-invasive. Especially in combination with bioinformatic data analysis, they offer great potential for industrial application. Known as soft sensors, they usually enable simultaneous estimation of multiple biological variables besides viability to be obtained from the same set of measurement data. However, the majority of the presented sensors are still in the research stage, and only a few are already commercially available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/bioengineering9120762

Cites

129 of 129 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Application of spectroscopic methods for cell viability determination. Changes in cell morphology, metabolism and membrane integrity due to a change in cell viability can be detected via spectroscopic methods. Various optical properties in specific wavelength ranges can be exploited for this purpose.
Figure 1 Application of spectroscopic methods for cell viability determination. Changes in cell morphology, metabolism and membrane integrity due to a change in cell viability can be detected via spectroscopic methods. Various optical properties in specific wavelength ranges can be exploited for this purpose.CC BY · PubMed Central
Figure 2 Monitoring of cell viability using different UV-vis spectroscopic methods. Different physical effects can be used for analyzing turbid cell suspensions depending on the arrangement of the light source and the detector. Based on [2].
Figure 2 Monitoring of cell viability using different UV-vis spectroscopic methods. Different physical effects can be used for analyzing turbid cell suspensions depending on the arrangement of the light source and the detector. Based on [2].CC BY · PubMed Central
Figure 3 Jablonski diagram for illustration of electronic states and the radiative and non-radiative transitions between electronic states explaining fluorescence phenomena. Adapted with permission from [47]. Faassen and Hitzmann, 2016.
Figure 3 Jablonski diagram for illustration of electronic states and the radiative and non-radiative transitions between electronic states explaining fluorescence phenomena. Adapted with permission from [47]. Faassen and Hitzmann, 2016.CC BY · PubMed Central
Figure 4 Fluorescence diagram of a fermentation broth of S. cerevisiae showing fluorescence signals of: (1) flavin, (2) riboflavin, (3) NADH, (4) NADPH, (5) pyridoxine, (6) tryptophan and (7) tyrosine. Adapted with permission from [47]. Faassen and Hitzmann, 2016.
Figure 4 Fluorescence diagram of a fermentation broth of S. cerevisiae showing fluorescence signals of: (1) flavin, (2) riboflavin, (3) NADH, (4) NADPH, (5) pyridoxine, (6) tryptophan and (7) tyrosine. Adapted with permission from [47]. Faassen and Hitzmann, 2016.CC BY · PubMed Central
Figure 5 Principle of capacitance measurement for cell viability determination. Only viable cells are polarized by the electric field and contribute to the capacitance signal. Dead cells cannot be polarized.
Figure 5 Principle of capacitance measurement for cell viability determination. Only viable cells are polarized by the electric field and contribute to the capacitance signal. Dead cells cannot be polarized.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 129 references

Research works printed but not linked: 6

  1. Doran, P.M. (2004). Bioprocess Engineering Principles, Elsevier.
  2. Reis, G.B., Horta, A.C., Zangirolami, T.C., Giordano, R.C., and Cruz, A.J. (2009). 10th International Symposium on Process Systems Engineering, Elsevier.
  3. Fortuna, L. (2007). Soft Sensors for Monitoring and Control of Industrial Processes, Springer.
  4. Rathore, 2015, Use of Multivariant Data Analysis in Bioprocessing, BioPharm Int., 28, 26
  5. Hergeth, W.-D. (2000). Ullmann’s Encyclopedia of Industrial Chemistry, Wiley-VCH Verlag GmbH & Co. KGaA.
  6. Veloso, A.C., and Ferreira, E.C. (2017). Current Developments in Biotechnology and Bioengineering, Elsevier.

Cited by

Metadata

Authors
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S.
Affiliations
  • Leibniz University Hannover (DE)
  • PreSens Precision Sensing (Germany) (DE)
Corresponding author
Beutel, Sascha
Venue
Bioengineering
Publisher
MDPI AG
Published
2022-12-03
Volume
9
Issue
12
Pages
762
ISSN
2306-5354 (ISSN-L)
OpenAlex
W4311628288
Cited by
42
References
129
Citations by year
2026: 14 · 2025: 14 · 2024: 8 · 2023: 6
FWCI
0.79
Type
journal article
Language
en
Open access
Locations
  • Bioengineering (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by)
  • Leibniz Universität Hannover (cc-by)
Funders
  • Federal Ministry for Economic Affairs and Energy (KK5344001LU1)
  • Open Access fund of Leibniz University Hannover (KK5344001LU1)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
Keywords
cell viability, online monitoring, bioprocess monitoring, soft sensors, non-invasive measurement, industrial bioprocessing, cell density

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.