Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Open accessThe DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
In recent years, the bioprocessing industry has experienced significant growth and is increasingly emerging as an important economic sector. Here, efficient process management and constant control of cellular growth are essential. Good product quality and yield can only be guaranteed with high cell density and high viability. Whereas the on-line measurement of physical and chemical process parameters has been common practice for many years, the on-line determination of viability remains a challenge and few commercial on-line measurement methods have been developed to date for determining viability in industrial bioprocesses. Thus, numerous studies have recently been conducted to develop sensors for on-line viability estimation, especially in the field of optical spectroscopic sensors, which will be the focus of this review. Spectroscopic sensors are versatile, on-line and mostly non-invasive. Especially in combination with bioinformatic data analysis, they offer great potential for industrial application. Known as soft sensors, they usually enable simultaneous estimation of multiple biological variables besides viability to be obtained from the same set of measurement data. However, the majority of the presented sensors are still in the research stage, and only a few are already commercially available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Monitoring of cell viability using different UV-vis spectroscopic methods. Different physical effects can be used for analyzing turbid cell suspensions depending on the arrangement of the light source and the detector. Based on [2].](https://figures.cochat.ai/paper-figures/ce6d5b96c07e47f7b685c63d1e3276fe/sensors-and-techniques-for-on-line-determination-of-cell-viability-in-bioprocess-figure-2.jpg)
![Figure 3 Jablonski diagram for illustration of electronic states and the radiative and non-radiative transitions between electronic states explaining fluorescence phenomena. Adapted with permission from [47]. Faassen and Hitzmann, 2016.](https://figures.cochat.ai/paper-figures/97ebaba09fea443f9ca11cd8b6b94f1e/sensors-and-techniques-for-on-line-determination-of-cell-viability-in-bioprocess-figure-3.jpg)
![Figure 4 Fluorescence diagram of a fermentation broth of S. cerevisiae showing fluorescence signals of: (1) flavin, (2) riboflavin, (3) NADH, (4) NADPH, (5) pyridoxine, (6) tryptophan and (7) tyrosine. Adapted with permission from [47]. Faassen and Hitzmann, 2016.](https://figures.cochat.ai/paper-figures/d33faa4a3fe94c40b2721a7e8dc76006/sensors-and-techniques-for-on-line-determination-of-cell-viability-in-bioprocess-figure-4.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Offline measurements are laborious, not immediate, require qualified manpower, and are prone to an increased risk of contamination (Claßen et al. 2017; Noll and Henkel 2020; Rösner et al. 2022).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Rösner et al. 2022
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“For some of these process variables, e.g., viability, online spectroscopic methods using software sensors for signal processing are already being developed (Rösner et al. 2022).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Rösner et al. 2022
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845 · cited 4×
“In addition, the actual state of the process is represented more accurately using black-box sensors since they process real-time data of the cultivation [118,122].”
BackgroundMethodInfluentialTelemedicine for Healthcare: Capabilities, Features, Barriers, and Applications
Haleem, A., Javaid, M., Singh, R. P., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100117 · Cited by 1,638
Deep learning for cellular image analysis
Moen, E., Bannon, D., Kudo, T., Graf, W., Covert, M., & Van Valen, D. (2019) · Nature Methods · doi:10.1038/s41592-019-0403-1 · Cited by 1,225
NAD+ metabolism: pathophysiologic mechanisms and therapeutic potential
Xie, N., Zhang, L., Gao, W., Huang, C., Huber, P. E., Zhou, X., Li, C., Shen, G., & Zou, B. (2020) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-020-00311-7 · Cited by 1,052
Near Infrared Spectroscopy: fundamentals, practical aspects and analytical applications
Pasquini, C. (2003) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50532003000200006 · Cited by 922 · cited 1×
“Additionally, for this spectroscopic method, resolving the spectra into its constituents via PCA methods is mandatory [79].”
MethodFlow cytometry: basic principles and applications
Adan, A., Alizada, G., Kiraz, Y., Baran, Y., & Nalbant, A. (2017) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2015.1128876 · Cited by 920 · cited 1×
“In flow cytometry, forward- (FSC) and side-scatter intensity (90◦, SSC) can be analyzed to obtain information on the size or the internal granularity of single cells [40,41].”
BackgroundGuidelines for cell viability assays
Kamiloglu, S., Sari, G., Ozdal, T., & Capanoglu, E. (2020) · Food Frontiers · doi:10.1002/fft2.44 · Cited by 769 · cited 3×
“Common cytotoxicity and viability staining methods can also be applied to cytometry [22].”
BackgroundMethodInfluentialMcKinnon, K. M. (2018) · Current Protocols in Immunology · doi:10.1002/cpim.40 · Cited by 728 · cited 1×
“In flow cytometry, forward- (FSC) and side-scatter intensity (90◦, SSC) can be analyzed to obtain information on the size or the internal granularity of single cells [40,41].”
BackgroundIntracellular Coenzymes as Natural Biomarkers for Metabolic Activities and Mitochondrial Anomalies
Heikal, A. A. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.10.1 · Cited by 458 · cited 1×
“Based on the existence or absence and the amount of these substances, fluorescence spectroscopy offers a wide range of information on the cellular state, and thus, has been used for bioprocess monitoring for many years [47,48].”
BackgroundBioreaction Engineering Principles
Villadsen, J., Nielsen, J., & Lidén, G. (2011) · Springer eBooks · doi:10.1007/978-1-4419-9688-6 · Cited by 432
Research works printed but not linked: 6
- Doran, P.M. (2004). Bioprocess Engineering Principles, Elsevier.
- Reis, G.B., Horta, A.C., Zangirolami, T.C., Giordano, R.C., and Cruz, A.J. (2009). 10th International Symposium on Process Systems Engineering, Elsevier.
- Fortuna, L. (2007). Soft Sensors for Monitoring and Control of Industrial Processes, Springer.
- Rathore, 2015, Use of Multivariant Data Analysis in Bioprocessing, BioPharm Int., 28, 26
- Hergeth, W.-D. (2000). Ullmann’s Encyclopedia of Industrial Chemistry, Wiley-VCH Verlag GmbH & Co. KGaA.
- Veloso, A.C., and Ferreira, E.C. (2017). Current Developments in Biotechnology and Bioengineering, Elsevier.
Cited by
Kumari, S. M. N. S., & Xavier, T. S. (2024) · ACS Omega · doi:10.1021/acsomega.4c07991 · Cited by 126
Software sensors in the monitoring of microalgae cultivations
Porras Reyes, L., Havlik, I., & Beutel, S. (2024) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-023-09679-8 · Cited by 48
“Offline measurements are laborious, not immediate, require qualified manpower, and are prone to an increased risk of contamination (Claßen et al. 2017; Noll and Henkel 2020; Rösner et al. 2022).”
InfluentialSelf-citationA roadmap for model-based bioprocess development
Mu'azzam, K., da Silva, F. V. S., Murtagh, J., & Sousa-Gallagher, M. J. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108378 · Cited by 69
Stanbury, P. F., Whitaker, A., & Hall, S. J. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-99273-2.00001-4 · Cited by 29
Current and future technologies for monitoring cultured meat: A review
Pawar, D., Presti, D. L., Silvestri, S., Schena, E., & Massaroni, C. (2023) · Food Research International · doi:10.1016/j.foodres.2023.113464 · Cited by 27
Metadata
- Authors
- Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S.
- Affiliations
- Leibniz University Hannover (DE)
- PreSens Precision Sensing (Germany) (DE)
- Corresponding author
- Beutel, Sascha
- ORCID
- Beutel, Sascha
- Venue
- Bioengineering
- Publisher
- MDPI AG
- Published
- 2022-12-03
- Volume
- 9
- Issue
- 12
- Pages
- 762
- ISSN
- 2306-5354 (ISSN-L)
- PMC
- PMC9774925
- OpenAlex
- W4311628288
- Semantic Scholar
- 1af68db566ea3509737780821c2155e875752744
- Cited by
- 42
- References
- 129
- Citations by year
- 2026: 14 · 2025: 14 · 2024: 8 · 2023: 6
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Bioengineering (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by)
- Leibniz Universität Hannover (cc-by)
- Funders
- Federal Ministry for Economic Affairs and Energy (KK5344001LU1)
- Open Access fund of Leibniz University Hannover (KK5344001LU1)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- cell viability, online monitoring, bioprocess monitoring, soft sensors, non-invasive measurement, industrial bioprocessing, cell density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.