Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose Detection

Shu, Yun, Su, Tong, Lu, Qin, Shang, Zhenjiao, Xu, Qin, Hu, Xiaoya·2021·Analytical Chemistry

Abstract

A noninvasive fiber material-based wearable electrochemical sensor to continuously monitor the glucose level in sweat is highly desirable for smart fabrics for personal diabetes management. To achieve it, the key challenge is to construct fibers with high stretchability and excellent electrochemical performance. Herein, a highly stretchable Ni–Co metal–organic framework/Ag/reduced graphene oxide/polyurethane (Ni–Co MOF/Ag/rGO/PU) fiber-based wearable electrochemical sensor is fabricated for monitoring the glucose level in sweat continuously with high sensitivity and accuracy. The rGO/PU fiber was simply produced by an improved wet spinning technology, and the Ni–Co MOF nanosheet was coated on its surface to prepare the Ni–Co MOF/Ag/rGO/PU (NCGP) fiber electrode. The Ni–Co MOF has a large specific surface area and high catalytic activity, which enables the fiber sensors with good electrochemical performance with a high sensitivity of 425.9 μA·mM –1 ·cm –2 and a wide linear range of 10 μM–0.66 mM. More importantly, the NCGP fiber electrode also shows extremely high stretching and bending stability under mechanical deformation. Also, the NCGP fiber electrode has high selectivity and long-time storage stability. Moreover, the NCGP fiber-based three-electrode system was sewn with an absorbent fabric and fixed on a stretchable polydimethylsiloxane film substrate to form a nonenzymatic sweat glucose wearable sensor, which realized real-time monitoring of glucose in human sweat with high accuracy. This indicates that our designed NCGP fiber can be used as a wearable electrochemical sensor for the bio-diagnostics of body sweat.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c04106

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 221

Metadata

Authors
Shu, Y., Su, T., Lu, Q., Shang, Z., Xu, Q., & Hu, X.
Venue
Analytical Chemistry
Published
2021-11-23
Volume
93
Issue
48
Pages
16222-16230
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3216400282
Cited by
221
References
9
FWCI
10.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.1c04106
The paper
Shu, Y., Su, T., Lu, Q., Shang, Z., Xu, Q., & Hu, X. (2021). Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.1c04106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.