Cancer-on-a-Chip: Models for Studying Metastasis
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The microfluidic-based cancer-on-a-chip models work as a powerful tool to study the tumor microenvironment and its role in metastasis. The models recapitulate and systematically simplify the in vitro tumor microenvironment. This enables the study of a metastatic process in unprecedented detail. This review examines the development of cancer-on-a-chip microfluidic platforms at the invasion/intravasation, extravasation, and angiogenesis steps over the last three years. The on-chip modeling of mechanical cues involved in the metastasis cascade are also discussed. Finally, the popular design of microfluidic chip models for each step are discussed along with the challenges and perspectives of cancer-on-a-chip models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor-associated macrophages: an accomplice in solid tumor progression
Chen, Y., Song, Y., Du, W., Gong, L., Chang, H., & Zou, Z. (2019) · Journal of Biomedical Science · doi:10.1186/s12929-019-0568-z · Cited by 1,096
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906 · cited 1×
“Designing cancer-on-a-chip models with perfused microvessels that can represent endothelial cell lining, angiogenesis or vasculogenesis is still a great challenge [45,46].”
BackgroundMechanotransduction in tumor progression: The dark side of the force
Broders-Bondon, F., Nguyen Ho-Bouldoires, T. H., Fernandez-Sanchez, M.-E., & Farge, E. (2018) · Journal of Cell Biology · doi:10.1083/jcb.201701039 · Cited by 319 · cited 1×
“Excessive matrix remodeling, driven by TME, leads to the changes in ECM physical properties, which have been linked to cell migration, malignant transformation, and EMT activation [52].”
BackgroundRecent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277 · cited 2×
“The development of microfluidic devices that closely resemble the blood vessels’ architecture (round channel-like structure with a lumen) results from the importance of tumor vessels during the intravasation process [13].”
BackgroundChen, M. B., Hajal, C., Benjamin, D. C., Yu, C., Azizgolshani, H., Hynes, R. O., & Kamm, R. D. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1715932115 · Cited by 183 · cited 2×
“In the metastasis process, both collaborative and antagonistic interactions between host microenvironmental factors and tumor cells take place [4].”
BackgroundMethodA review of microfluidic approaches for investigating cancer extravasation during metastasis
Ma, Y.-H. V., Middleton, K., You, L., & Sun, Y. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.104 · Cited by 154
Truong, D. D., Kratz, A., Park, J. G., Barrientos, E. S., Saini, H., Nguyen, T., Pockaj, B., Mouneimne, G., LaBaer, J., & Nikkhah, M. (2019) · Cancer Research · doi:10.1158/0008-5472.can-18-2293 · Cited by 149 · cited 2×
“Some recent studies have involved the patient-derived samples replicating personal physiologically relevant TME [24].”
BackgroundBone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142 · cited 1×
“The capability of simulating gradient factors (such as fluidic flow, oxygen, drug), tissue mechanics, tissue engineering, and local environmental compositions enable these “on-chip” platforms as powerful tools for studying the complicated interactions that are involved in the metastatic process [9].”
BackgroundApplications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128 · cited 1×
“Twodimensional (2D) cell culture and animal models are traditional cancer investigation models, but these cannot recapitulate the tumor microenvironment (TME) that is relevant to human physiology [5,6].”
BackgroundMetastasis in context: modeling the tumor microenvironment with cancer-on-a-chip approaches
Sleeboom, J. J. F., Eslami Amirabadi, H., Nair, P., Sahlgren, C. M., & den Toonder, J. M. J. (2018) · Disease Models & Mechanisms · doi:10.1242/dmm.033100 · Cited by 122 · cited 2×
“The recently developed cancer-on-a-chip models, containing small chambers, are evolving as powerful tools to investigate the TME and its contribution in metastasis [7].”
Background
Cited by
Recent advances in vascularized tumor-on-a-chip
Huang, C. B. X., & Tu, T.-Y. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1150332 · Cited by 34
Microfluidic systems for modeling digestive cancer: a review of recent progress
Razavi, Z., Soltani, M., Pazoki-Toroudi, H., & Dabagh, M. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad6f15 · Cited by 24
Padmyastuti, A., Sarmiento, M. G., Dib, M., Ehrhardt, J., Schoon, J., Somova, M., Burchardt, M., Roennau, C., & Pinto, P. C. (2023) · Scientific Reports · doi:10.1038/s41598-023-38834-y · Cited by 17
Metadata
- Authors
- Zhang, X., Karim, M., Hasan, M. M., Hooper, J., Wahab, R., Roy, S., & Al-Hilal, T. A.
- Venue
- Cancers
- Publisher
- MDPI AG
- Published
- 2022-01-27
- Volume
- 14
- Issue
- 3
- Pages
- 648
- ISSN
- 2072-6694 (ISSN-L)
- OpenAlex
- W4210787916
- Cited by
- 71
- References
- 17
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cancer-on-a-Chip: Models for Studying Metastasis. https://app.cochat.ai/papers/10.3390/cancers14030648
- The paper
- Zhang, X., Karim, M., Hasan, M. M., Hooper, J., Wahab, R., Roy, S., & Al-Hilal, T. A. (2022). Cancer-on-a-Chip: Models for Studying Metastasis. Cancers. https://doi.org/10.3390/cancers14030648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.