Electrospun PLGA Fiber Diameter and Alignment of Tendon Biomimetic Fleece Potentiate Tenogenic Differentiation and Immunomodulatory Function of Amniotic Epithelial Stem Cells
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Injured tendons are challenging in their regeneration; thus, tissue engineering represents a promising solution. This research tests the hypothesis that the response of amniotic epithelial stem cells (AECs) can be modulated by fiber diameter size of tendon biomimetic fleeces. Particularly, the effect of electrospun poly(lactide-co-glycolide) (PLGA) fleeces with highly aligned microfibers possessing two different diameter sizes (1.27 and 2.5 µm: ha1- and ha2-PLGA, respectively) was tested on the ability of AECs to differentiate towards the tenogenic lineage by analyzing tendon related markers (Collagen type I: COL1 protein and mRNA Scleraxis: SCX, Tenomodulin: TNMD and COL1 gene expressions) and to modulate their immunomodulatory properties by investigating the pro- (IL-6 and IL-12) and anti- (IL-4 and IL-10) inflammatory cytokines. It was observed that fiber alignment and not fiber size influenced cell morphology determining the morphological change of AECs from cuboidal to fusiform tenocyte-like shape. Instead, fleece mechanical properties, cell proliferation, tenogenic differentiation, and immunomodulation were regulated by changing the ha-PLGA microfiber diameter size. Specifically, higher DNA quantity and better penetration within the fleece were found on ha2-PLGA, while ha1-PLGA fleeces with small fiber diameter size had better mechanical features and were more effective on AECs trans-differentiation towards the tenogenic lineage by significantly translating more efficiently SCX into the downstream effector TNMD. Moreover, the fiber diameter of 1.27 µm induced higher expression of pro-regenerative, anti-inflammatory interleukins mRNA expression (IL-4 and IL-10) with favorable IL-12/IL-10 ratio with respect to the fiber diameter of 2.5 µm. The obtained results demonstrate that fiber diameter is a key factor to be considered when designing tendon biomimetic fleece for tissue repair and provide new insights into the importance of controlling matrix parameters in enhancing cell differentiation and immunomodulation either for the cells functionalized within or for the transplanted host tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Biodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416 · cited 1×
“It is known that PLGA, in particular, provides sufficient control of degradation [77,78] conjugated to adequate mechanical strength that fosters its application in tissue remodeling and regeneration [79,80], and thus widely used in tendon tissue engineering.”
BackgroundBiomaterials & scaffolds for tissue engineering
O'Brien, F. J. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70058-x · Cited by 3,437
Formulation of functionalized PLGA-PEG Nanoparticles for in vivo targeted drug delivery
Cheng, J., Teply, B. A., Sherifi, I., Sung, J., Luther, G., Gu, F. X., Levy-Nissenbaum, E., Radovic-Moreno, A. F., Langer, R., & Farokhzad, O. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.047 · Cited by 1,273
Electrospinning for tissue engineering scaffolds
Lannutti, J., Reneker, D., Ma, T., Tomasko, D., & Farson, D. (2007) · Materials Science and Engineering: C · doi:10.1016/j.msec.2006.05.019 · Cited by 693
In vitro and in vivo degradation of porous poly(dl-lactic-co-glycolic acid) foams
Lu, L., Peter, S. J., D. Lyman, M., Lai, H.-L., Leite, S. M., Tamada, J. A., Uyama, S., Vacanti, J. P., Langer, R., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00047-8 · Cited by 668
Garg, K., Pullen, N. A., Oskeritzian, C. A., Ryan, J. J., & Bowlin, G. L. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.065 · Cited by 457
Monocytes and macrophages in tissue repair: Implications for immunoregenerative biomaterial design
Ogle, M. E., Segar, C. E., Sridhar, S., & Botchwey, E. A. (2016) · Experimental Biology and Medicine · doi:10.1177/1535370216650293 · Cited by 378 · cited 2×
“Immunomodulation through biomaterials, alignment of the scaffolds, and fiber diameter affects the polarization of macrophages from inflammatory (M1) to anti-inflammatory/pro-regenerative (M2) phenotypes [61,63,113,114] or even potentiates stem cell immunomodulatory function [62,98,115].”
BackgroundSaino, E., Focarete, M. L., Gualandi, C., Emanuele, E., Cornaglia, A. I., Imbriani, M., & Visai, L. (2011) · Biomacromolecules · doi:10.1021/bm200248h · Cited by 285 · cited 3×
“In this context, the immunoregulatory function of MSCs cultured on aligned fibers scaffold was enhanced compared to MSCs cultured on randomly arranged fibers [62], and the secretion of proinflammatory molecules by macrophage cells (Mφ) was mainly dependent on fiber diameter [63].”
Background
Cited by
Cao, H., Duan, L., Zhang, Y., Cao, J., & Zhang, K. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00830-x · Cited by 1,274
Ye, J., Xie, C., Wang, C., Huang, J., Yin, Z., Heng, B. C., Chen, X., & Shen, W. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.04.017 · Cited by 97
Biomimetic immunomodulation strategies for effective tissue repair and restoration
Villarreal-Leal, R. A., Healey, G. D., & Corradetti, B. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113913 · Cited by 86
Scaffold-Mediated Immunoengineering as Innovative Strategy for Tendon Regeneration
Russo, V., El Khatib, M., Prencipe, G., Cerveró-Varona, A., Citeroni, M. R., Mauro, A., Berardinelli, P., Faydaver, M., Haidar-Montes, A. A., Turriani, M., et al. (2022) · Cells · doi:10.3390/cells11020266 · Cited by 49
Self-citation
Metadata
- Authors
- El Khatib, M., Mauro, A., Di Mattia, M., Wyrwa, R., Schweder, M., Ancora, M., Lazzaro, F., Berardinelli, P., Valbonetti, L., Di Giacinto, O., Polci, A., Cammà, C., Schnabelrauch, M., Barboni, B., & Russo, V.
- Venue
- Cells
- Publisher
- MDPI AG
- Published
- 2020-05-13
- Volume
- 9
- Issue
- 5
- Pages
- 1207
- ISSN
- 2073-4409 (ISSN-L)
- OpenAlex
- W3025949689
- Cited by
- 59
- References
- 9
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrospun PLGA Fiber Diameter and Alignment of Tendon Biomimetic Fleece Potentiate Tenogenic Differentiation and Immunomodulatory Function of Amniotic Epithelial Stem Cells. https://app.cochat.ai/papers/10.3390/cells9051207
- The paper
- El Khatib, M., Mauro, A., Di Mattia, M., Wyrwa, R., Schweder, M., Ancora, M., Lazzaro, F., Berardinelli, P., Valbonetti, L., Di Giacinto, O., Polci, A., Cammà, C., Schnabelrauch, M., Barboni, B., & Russo, V. (2020). Electrospun PLGA Fiber Diameter and Alignment of Tendon Biomimetic Fleece Potentiate Tenogenic Differentiation and Immunomodulatory Function of Amniotic Epithelial Stem Cells. Cells. https://doi.org/10.3390/cells9051207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.