The Challenges of Developing Biosensors for Clinical Assessment: A Review
Published version of a preprint
The DOI matches its Crossref record; 170 of the 170 references it cites were found in a registry or an index.
Abstract
Emerging research in biosensors has attracted much attention worldwide, particularly in response to the recent pandemic outbreak of coronavirus disease 2019 (COVID-19). Nevertheless, initiating research in biosensing applied to the diagnosis of diseases is still challenging for researchers, be it in the preferences of biosensor platforms, selection of biomarkers, detection strategies, or other aspects (e.g., cutoff values) to fulfill the clinical purpose. There are two sides to the development of a diagnostic tool: the biosensor development side and the clinical side. From the development side, the research engineers seek the typical characteristics of a biosensor: sensitivity, selectivity, linearity, stability, and reproducibility. On the other side are the physicians that expect a diagnostic tool that provides fast acquisition of patient information to obtain an early diagnosis or an efficient patient stratification, which consequently allows for making assertive and efficient clinical decisions. The development of diagnostic devices always involves assay developer researchers working as pivots to bridge both sides whose role is to find detection strategies suitable to the clinical needs by understanding (1) the intended use of the technology and its basic principle and (2) the preferable type of test: qualitative or quantitative, sample matrix challenges, biomarker(s) threshold (cutoff value), and if the system requires a mono- or multiplex assay format. This review highlights the challenges for the development of biosensors for clinical assessment and its broad application in multidisciplinary fields. This review paper highlights the following biosensor technologies: magnetoresistive (MR)-based, transistor-based, quartz crystal microbalance (QCM), and optical-based biosensors. Its working mechanisms are discussed with their pros and cons. The article also gives an overview of the most critical parameters that are optimized by developing a diagnostic tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework
(2001) · Clinical Pharmacology & Therapeutics · doi:10.1067/mcp.2001.113989 · Cited by 6,762
Strimbu, K., & Tavel, J. A. (2010) · Current Opinion in HIV and AIDS · doi:10.1097/coh.0b013e32833ed177 · Cited by 2,062
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,047
Bartlett, J. W., & Frost, C. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5256 · Cited by 936
Ultrasensitive surface-enhanced Raman scattering detection in common fluids
Yang, S., Dai, X., Stogin, B. B., & Wong, T.-S. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1518980113 · Cited by 704
C-reactive protein levels in the early stage of COVID-19
Wang, L. (2020) · Médecine et Maladies Infectieuses · doi:10.1016/j.medmal.2020.03.007 · Cited by 686
Fu, Y. Q., Luo, J. K., Nguyen, N. T., Walton, A. J., Flewitt, A. J., Zu, X. T., Li, Y., McHale, G., Matthews, A., Iborra, E., et al. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.006 · Cited by 646
Research works printed but not linked: 11
- Nagel, 2009, Glossary for chemists of terms used in biotechnology (IUPAC Recommendations 1992), Pure Appl. Chem., 64, 143, 10.1351/pac199264010143 · DOI
- Jing, 2020, Engineering Field Effect Transistors with 2D Semiconducting Channels: Status and Prospects, Adv. Funct. Mater., 30, 1
- Long, 1983, Limit of Detection a Closer Look at the IUPAC Definition, Anal. Chem., 55, 712A
- Currie, 1999, Nomenclature in evaluation of analytical methods including detection and quantification capabilities. Adapted from the International Union of Pure and Applied Chemistry (IUPAC) document “Nomenclature in Evaluation of Analytical Methods including Detection, Anal. Chim. Acta, 391, 105, 10.1016/S0003-2670(99)00104-X · DOI
- Wang, 2012, Without-baseline centroid algorithm for surface plasmon resonance spectra, Chin. J. Sens. Actuators, 25, 365
- Hamzeiy, 2014, Nanoscaled aptasensors for multi-analyte sensing, BioImpacts, 4, 205
- Seher, 2011, Gene expression profiling of connective tissue growth factor (CTGF) stimulated primary human tenon fibroblasts reveals an inflammatory and wound healing response in vitro, Mol. Vis., 17, 53
- Patra, 2017, Using extraordinary optical transmission to quantify cardiac biomarkers in human serum, J. Vis. Exp., 2017, 55597
- Ewald, 2020, A multi-analyte biosensor for the simultaneous label-free detection of pathogens and biomarkers in point-of-need animal testing, Anal. Bioanal. Chem., 407, 4005, 10.1007/s00216-015-8562-0 · doi:10.1007/s00216-015-8562-0
- Wang, Y.Y., Yuan, W., Zhang, Q., Wang, Y.Y., Kimber, M., Dong, L., and Lu, M. Exosome microarray based on label-free imaging biosensor. Proceedings of the IEEE Sensors.
- Prasad, 2017, Companion and Point-of-Care Sensor System for Rapid Multiplexed Detection of a Panel of Infectious Disease Markers, SLAS Technol. Transl. Life Sci. Innov., 22, 338
Cited by
AI-Assisted Detection of Biomarkers by Sensors and Biosensors for Early Diagnosis and Monitoring
Wasilewski, T., Kamysz, W., & Gębicki, J. (2024) · Biosensors · doi:10.3390/bios14070356 · Cited by 290
FluorMango, an RNA-based fluorogenic biosensor for the direct and specific detection of fluoride
Husser, C., Vuilleumier, S., & Ryckelynck, M. (2023) · Small · doi:10.1002/smll.202205232 · Cited by 30
Metadata
- Authors
- Prabowo, B. A., Cabral, P. D., Freitas, P., & Fernandes, E.
- Venue
- Chemosensors
- Publisher
- MDPI AG
- Published
- 2021-10-24
- Volume
- 9
- Issue
- 11
- Pages
- 299
- ISSN
- 2227-9040
- Cited by
- 113
- References
- 170
- Language
- en
- Funders
- Fundação para a Ciência e Tecnologia (PTDC/MEC-URG/29561/2017, SFRH/BD/128579/2017)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.