Ultra-Long-Term Reliable Encapsulation Using an Atomic Layer Deposited HfO2/Al2O3/HfO2 Triple-Interlayer for Biomedical Implants
Open accessThe DOI matches its Crossref record; 46 of the 51 references it cites were found in a registry or an index.
Abstract
Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO2/Al2O3/HfO2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al2O3, ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Recently developed thin-film µECoG arrays have demonstrated the ability to conform to the brain surface safely for several months while reliably recording multi-unit and single-unit activity in certain anatomic settings 53,57 .”
From The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform (2022) · cites this paper as [57]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic Layer Deposition: An Overview
George, S. M. (2010) · Chemical Reviews · doi:10.1021/cr900056b · Cited by 5,814
Comprehensive Handbook of Chemical Bond Energies
Luo, Y.-R. (2007) · CRC Press eBooks · doi:10.1201/9781420007282 · Cited by 3,881 · cited 1×
“HfO2 is chemically inert and insoluble in aqueous solutions [22,28,31].”
Crystallinity of inorganic films grown by atomic layer deposition: Overview and general trends
Miikkulainen, V., Leskelä, M., Ritala, M., & Puurunen, R. L. (2013) · Journal of Applied Physics · doi:10.1063/1.4757907 · Cited by 1,413 · cited 1×
“In general, ALD layers have three important properties that make them ideal to serve as a barrier layer: they are nearly pin-hole free, are highly conformal, and a limited thickness (5–100 nm) is required [20,21].”
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Material challenge for flexible organic devices
Lewis, J. (2006) · Materials Today · doi:10.1016/s1369-7021(06)71446-8 · Cited by 662 · cited 1×
“This is generally expressed as water vapor transmission rates (WVTR) in the order of 1–100 g·m−2·day−1 [13].”
A wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501 · cited 1×
“The biocompatibility of polyimide has been proved in many in vitro and in vivo researches [34,37,38].”
Al2O3 and TiO2 Atomic Layer Deposition on Copper for Water Corrosion Resistance
Abdulagatov, A. I., Yan, Y., Cooper, J. R., Zhang, Y., Gibbs, Z. M., Cavanagh, A. S., Yang, R. G., Lee, Y. C., & George, S. M. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am2009579 · Cited by 300 · cited 3×
“Therefore, other ALD oxides like TiO2 [17,22], SiO2 [6,29], and HfO2 [25,30] have been investigated as an alternative layer or capping layer of Al2O3 to increase the stability and barrier properties in a liquid water environment.”
Díaz, B., Härkönen, E., Światowska, J., Maurice, V., Seyeux, A., Marcus, P., & Ritala, M. (2011) · Corrosion Science · doi:10.1016/j.corsci.2011.02.036 · Cited by 244
Research works printed but not linked: 4
- 3. Jiang, G.; Zhou, D.D. Implantable Neural Prostheses 2 ; Springer: New York, NY, USA, 2010; ISBN 978-0-38798119-2.
- 39. Loveday, D.; Peterson, P.; Rodgers, B. Evaluation of organic coatings with electrochemical impedance spectroscopy part 2: Application of EIS to coatings. JCT Coat. Tech. 2004 , 1 , 88-93.
- 41. Loveday, D.; Peterson, P.; Rodgers, B. Evaluation of organic coatings with electrochemical impedance spectroscopy, part 3: Protocols for testing coatings with EIS. JCT Coat. Tech. 2005 , 2 , 22-27.
- 43. HD MicroSystems 'PI-2600 Series-Low Stress Applications' Product Bulletin. Available online: https://www.dupont.com/content/dam/dupont/products-and-services/electronic-and-electricalmaterials/semiconductor-fabrication-and-packaging-materials/documents/PI-2600\_ProcessGuide.pdf
Cited by
Ultra‐Thin Flexible Encapsulating Materials for Soft Bio‐Integrated Electronics
Sang, M., Kim, K., Shin, J., & Yu, K. J. (2022) · Advanced Science · doi:10.1002/advs.202202980 · Cited by 161
Advanced wearable biosensors for the detection of body fluids and exhaled breath by graphene
Singh, S. U., Chatterjee, S., Lone, S. A., Ho, H.-H., Kaswan, K., Peringeth, K., Khan, A., Chiang, Y., Lee, S., & Lin, Z. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05317-2 · Cited by 104
Recent advances in flexible and wearable OLEDs for biomedical applications: a review
Cho, E. H., Kim, Y., Sim, J., Yeon, H., Baek, S., Jeong, S. M., Lee, J., Jeon, Y., & Choi, K. C. (2025) · Materials Horizons · doi:10.1039/d5mh00742a · Cited by 60
Herbert, R., Elsisy, M. M., Rigo, B., Lim, H., Kim, H., Choi, C., Kim, S., Ye, S., Wagner, W. R., Chun, Y., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4029641 · Cited by 41
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
Towards robust flexible electronics: Fabrication approaches and ongoing research challenges
Omiyale, B. O., Ogbeyemi, A., Ashraf, M. A., Song, K., & Zhang, W. C. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117053 · Cited by 39
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M. E., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01501-w · Cited by 55
Khan, A. A., & Kim, J. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116461 · Cited by 33
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 32
“HfO 2 has also proven to create an effective barrier, and is often paired with Al 2 O 3 or SiO 2 [215, 220, 221].”
Carbon-Based Fiber Materials as Implantable Depth Neural Electrodes
Fu, X., Li, G., Niu, Y., Xu, J., Wang, P., Zhou, Z., Ye, Z., Liu, X., Xu, Z. J., Yang, Z., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.771980 · Cited by 22
“, which are grown directly by techniques such as ALD and CVD, offer superior insulation properties (Minnikanti et al., 2014; Ahn et al., 2019; Li et al., 2019).”
MethodLiu, X., Xu, Z. J., Fu, X., Liu, Y., Jia, H., Yang, Z., Zhang, J., Wei, S., & Duan, X. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac9258 · Cited by 25
Pak, A., Nanbakhsh, K., Hölck, O., Ritasalo, R., Sousa, M., Gompel, M. V., Pahl, B., Wilson, J., Kallmayer, C., & Giagka, V. (2022) · Micromachines · doi:10.3390/mi13040544 · Cited by 20
Thin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex
Merken, L., Schelles, M., Ceyssens, F., Kraft, M. D., & Janssen, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac98e2 · Cited by 21
“posite layer consisted of a stack of hafnium oxide (HfOx) (tetrakis(ethylmethylamido)hafnium(IV) as precursor, Sigma Aldrich), aluminum oxide (AlOx) (trimethylaluminum as precursor, Sigma Aldrich), and HfOx, to decrease water penetration through the polyimide and further improve the long-term isolation [45].”
BackgroundYoo, H., Lee, S.-H., Kwak, J.-Y., Kim, S., Jeong, H.-Y., Jo, J.-H., Kim, Y., Sim, Y., Kim, D.-H., Jeon, J., et al. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00545-5 · Cited by 17
Nanbakhsh, K., Ritasalo, R., Serdijn, W. A., & Giagka, V. (2020) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc32862.2020.00081 · Cited by 21
“Also, in [10], ALD stacks were used in between polyimide layers resulting in an increased packaging life-time.”
MethodRecent Achievements for Flexible Encapsulation Films Based on Atomic/Molecular Layer Deposition
Zhang, B., Wang, Z., Wang, J., & Chen, X. (2024) · Micromachines · doi:10.3390/mi15040478 · Cited by 16
Cunha, F. M., Silva, M. F., Gomes, N., & Correia, J. H. (2023) · Coatings · doi:10.3390/coatings13030638 · Cited by 10
Kim, J., Park, S., Kim, T. Y., Jo, Y., Park, K., & Seo, J. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500475 · Cited by 13
Nanbakhsh, K., Gompel, M. V., Ritasalo, R., Gollhardt, A., Horváth, D., Tóth, K., Meszéna, D., Ulbert, I., Serdijn, W. A., & Giagka, V. (2025) · Small · doi:10.1002/smll.202410141 · Cited by 11
Advances in Electrode Design and Physiological Considerations for Retinal Implants
Gong, C. A. (2025) · Micromachines · doi:10.3390/mi16050598 · Cited by 9
“Co-design of chips and encapsulation is poised to become mainstream [93].”
Parylene-AlOx Stacks for Improved 3D Encapsulation Solutions
Buchwalder, S., Bourgeois, F., Diaz, J. J., Hogg, A., & Burger, J. (2023) · Coatings · doi:10.3390/coatings13111942 · Cited by 7
Afshari, E., Verplancke, R., Cauwe, M., & de Beeck, M. O. (2025) · Coatings · doi:10.3390/coatings15060648 · Cited by 5
Self-citationTest Structures for Developing Packaging for Implantable Sensors
Blair, E. O., Buchoux, A., Tsiamis, A., Dunare, C. C., Marland, J. R. K., Gray, M., Terry, J. G., Smith, S., & Walton, A. J. (2020) · IEEE Transactions on Semiconductor Manufacturing · doi:10.1109/tsm.2020.2987134 · Cited by 5
“Adhesion between materials has often been identified as the main cause of failure in packaged sensors and methods such as atomic layer deposition and complex multilayer packaging solutions are often used as a response to this [30], [31].”
BackgroundBabaroud, N. B., Dekker, R. H., Holk, O., Tiringer, U., Taheri, P., Horváth, D., Nánási, T., Ulbert, I., Serdijn, W. A., & Giagka, V. (2021) · European Microelectronics and Packaging Conference · doi:10.23919/empc53418.2021.9584961 · Cited by 5
Afshari, E., Houri, S., Verplancke, R., Rochus, V., Cauwe, M., Gijsenbergh, P., & de Beeck, M. O. (2025) · Sensors · doi:10.3390/s25134074 · Cited by 4
Self-citationKim, Y. H., Lee, J., Lim, J. W., Kim, K., Ahn, D. H., Yang, C., Park, S., Kim, M. S., & Jung, S.-D. (2025) · Nanoscale · doi:10.1039/d4nr05179c · Cited by 4
Investigating the Nucleation of AlOx and HfOx ALD on Polyimide: Influence of Plasma Activation
Álvarez, L. A., Schaubroeck, D., Tabaei, P. S. E., Ghobeira, R., de Beeck, M. O., Morent, R., Smet, H. D., & Geyter, N. D. (2021) · Coatings · doi:10.3390/coatings11111352 · Cited by 4
Self-citationСоснов, Е. А., Маlkov, А. А., & Малыгин, А. А. (2021) · Russian Journal of Applied Chemistry · doi:10.1134/s1070427221090020 · Cited by 4
ICPECVD-Dielectric Thin-Films CMOS-Compatible: Trends in Eco-Friendly Deposition
Herth, É., & Rauch, J. (2021) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-021-00381-0 · Cited by 5
Chaya, N., Okamoto, K., Hirai, K., Yasuoka, S., Inoue, Y., Yamaoka, W., & Funakubo, H. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad3a71 · Cited by 3
Katirtsidis, G. A., Illa, X., Ria, N., del Corro, E., Masvidal‐Codina, E., & Garrido, J. A. (2025) · Small Methods · doi:10.1002/smtd.202501720 · Cited by 3
Li, C., Cauwe, M., Mader, L., Schaubroeck, D., & de Beeck, M. O. (2019) · Coatings · doi:10.3390/coatings10010019 · Cited by 26
Self-citationTowards CMOS Bulk Sensing for In-Situ Evaluation of ALD Coatings for Millimeter Sized Implants
Nanbakhsh, K., Ritasalo, R., Serdijn, W. A., & Giagka, V. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176103 · Cited by 2
“Atomic layer deposition (ALD) is a chemical vapor deposition process that can create a thin (ten to a few hundred nanometers) and conformal coating layer with near hermetic barrier properties [2], [4].”
BackgroundMethodStability of plasma‐enhanced atomic layer deposited barrier films in biological solutions
Singh, A. K., Adstedt, K. M., Miao, T., Champion, J. A., Singh, P. M., & Graham, S. L. (2020) · Engineering Reports · doi:10.1002/eng2.12303 · Cited by 2
Kalliomäki, J., Manninen, I., Ritasalo, R., & Hirsjärvi, S. (2024) · Advanced Engineering Materials · doi:10.1002/adem.202302257 · Cited by 1
Research Progress in Flexible and Stretchable Encapsulation Materials for Electronics
Yoo, H., Lee, S.-H., Kim, S.-M., Jo, J.-H., & Kim, J.-Y. (2025) · Journal of Flexible and Printed Electronics · doi:10.56767/jfpe.2025.4.1.15 · Cited by 1
Kim, G., Kim, C.-M., Jeong, J., Woo, H. J., Kwon, S., & Yang, H. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114550 · Cited by 1
Biocompatible Hermetic Encapsulation of PMUTs for Usage in Implantable Medical Devices
Afshari, E., Houri, S., Verplancke, R., Rochus, V., Cauwe, M., Gijsenbergh, P., Rottenberg, X., & de Beeck, M. O. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793944 · Cited by 1
Self-citationJussila, T., Pekkanen, J., Virta, A., Ghazy, A., Lastusaari, M., & Karppinen, M. J. (2025) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/6.0004237 · Cited by 1
Calibration of a QMS System for High-Sensitivity Gas Permeation Measurement
Wu, R., Zhang, L., Cao, K., Tian, S., Zhang, X., & Chen, R. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3300429
Biomaterials for Bionic Implants
Shokuhfar, T. (2025) · Wiley eBooks · doi:10.1002/9781119851004.ch8
Li, Z., Nambisan, R. M., & Gianchandani, Y. B. (2025) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers61432.2025.11111086
A High-Accuracy Solid/Liquid Composite Packaging Method for Implantable Pressure Sensors
Wang, B., Zhang, Y., Huang, Y., Li, Z., Jiang, S., Wang, F., Liu, Q., & Yang, X. (2026) · Micromachines · doi:10.3390/mi17020162
“…such as the eyeball [1,2], cranial cavity [3,4], and heart [5,6], these sensors must simultaneously meet stringent requirements for high-precision measurement, long-term stable operation, and excellent biocompatibility, which poses significant challenges to existing packaging technologies [7].”
Freestanding Functional Oxide Membranes for Wearable Electronics and Biomedical Applications
Peng, R., Liu, T., Dong, G., Dong, N., Hu, F., Zhang, X., Liu, M., Dong, T., & Jiang, Z. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202532192 · Cited by 1
Yang, M. S., & Xian, C. (2026) · Journal of Experimental and Theoretical Analyses · doi:10.3390/jeta4020021
Golgovici, F., Ioniță, D., Nartiţă, R., Prodana, M., & Demetrescu, I. (2026) · Coatings · doi:10.3390/coatings16070868
Metadata
- Authors
- Li, C., Cauwe, M., Yang, Y., Schaubroeck, D., Mader, L., & Op de Beeck, M.
- Affiliations
- Ghent University (BE)
- Pacific Northwest National Laboratory (US)
- Centre for Microsystems Technology (CMST), imec and Ghent University, Technologiepark 126, 9052 Gent, Belgium
- Corresponding author
- Cauwe, Maarten
- Venue
- Coatings
- Publisher
- MDPI AG
- Published
- 2019-09-12
- Volume
- 9
- Issue
- 9
- Pages
- 579
- ISSN
- 2079-6412 (ISSN-L)
- OpenAlex
- W2972568184
- Semantic Scholar
- 2b66280e00e1fdff3d10dbcf0a782ea96f61d7a4
- Cited by
- 46
- References
- 51
- Citations by year
- 2026: 5 · 2025: 14 · 2024: 5 · 2023: 4 · 2022: 7 · 2021: 5 · 2020: 5 · 2019: 1
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Coatings (publishedVersion, cc-by)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- China Scholarship Council (201406150084)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Copper Interconnects and Reliability
- Keywords
- hermetic encapsulation, biomedical implants, atomic layer deposition, polyimide, long-term reliability, biocompatible packaging, electrochemical stability, phosphate buffered saline, failure mode analysis, equivalent circuit model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.