A Machine Learning Approach for Anomaly Detection in Industrial Control Systems Based on Measurement Data
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Attack detection problems in industrial control systems (ICSs) are commonly known as a network traffic monitoring scheme for detecting abnormal activities. However, a network-based intrusion detection system can be deceived by attackers that imitate the system’s normal activity. In this work, we proposed a novel solution to this problem based on measurement data in the supervisory control and data acquisition (SCADA) system. The proposed approach is called measurement intrusion detection system (MIDS), which enables the system to detect any abnormal activity in the system even if the attacker tries to conceal it in the system’s control layer. A supervised machine learning model is generated to classify normal and abnormal activities in an ICS to evaluate the MIDS performance. A hardware-in-the-loop (HIL) testbed is developed to simulate the power generation units and exploit the attack dataset. In the proposed approach, we applied several machine learning models on the dataset, which show remarkable performances in detecting the dataset’s anomalies, especially stealthy attacks. The results show that the random forest is performing better than other classifier algorithms in detecting anomalies based on measured data in the testbed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SMOTE synthetic minority over-sampling technique
Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002) · Journal of Artificial Intelligence Research · doi:10.1613/jair.953 · Cited by 32,865
Comparison of the predicted and observed secondary structure of T4 phage lysozyme
Matthews, B. W. (1975) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(75)90109-9 · Cited by 5,399
A survey on feature selection methods
Chandrashekar, G., & Sahin, F. (2014) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2013.11.024 · Cited by 5,189
Developing a Hybrid Intrusion Detection System Using Data Mining for Power Systems
Pan, S., Morris, T., & Adhikari, U. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2409775 · Cited by 457 · cited 1×
“In [14], Pan et al. introduced an IDS strategy leveraging features of signature-based and specification-based detection methods which protects an electrical power transmission line from attacks.”
Cited by
Koay, A. M. Y., Ko, R. K. L., Hettema, H., & Radke, K. (2023) · Journal of Intelligent Information Systems · doi:10.1007/s10844-022-00753-1 · Cited by 131
Unsupervised Learning Approach for Anomaly Detection in Industrial Control Systems
Choi, W.-H., & Kim, J. (2024) · Applied System Innovation · doi:10.3390/asi7020018 · Cited by 74
Kus, D., Wagner, E., Pennekamp, J., Wolsing, K., Fink, I. B., Dahlmanns, M., Wehrle, K., & Henze, M. (2022) · Proceedings of the 8th ACM on Cyber-Physical System Security Workshop · doi:10.1145/3494107.3522773 · Cited by 28
Smart Anomaly Detection Using Data-Driven Techniques in IoT Edge: A Survey
Manokaran, J., & Vairavel, G. (2022) · Lecture Notes in Electrical Engineering · doi:10.1007/978-981-16-8862-1_45 · Cited by 13
Brenner, B., Hollerer, S., Bhosale, P., Sauter, T., Kastner, W., Fabini, J., & Zseby, T. (2023) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2023.3297057 · Cited by 12
Anomaly Detection Method Considering PLC Control Logic Structure for ICS Cyber Threat Detection
Lee, J. H., Ji, I. H., Jeon, S. H., & Seo, J. T. (2025) · Applied Sciences · doi:10.3390/app15073507 · Cited by 5
Metadata
- Authors
- Mokhtari, S., Abbaspour, A., Yen, K. K., & Sargolzaei, A.
- Venue
- Electronics
- Publisher
- MDPI AG
- Published
- 2021-02-08
- Volume
- 10
- Issue
- 4
- Pages
- 407
- ISSN
- 2079-9292 (ISSN-L)
- OpenAlex
- W3129057775
- Cited by
- 197
- References
- 4
- FWCI
- 16.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.