CoChat

Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy

Open access

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index; 5 of the 18 sources its claims cite were checked for support.

Abstract

One of the key elements of terahertz time-domain spectrometers is the optical delay line. Usually it consists of a motorized translation stage and a corner reflector mounted on its top. Errors in the positioning of the translation stage lead to various distortions of the measured waveform of terahertz pulses and, therefore, terahertz spectra. In this paper, the accuracy of position measurements is improved by using an optical encoder. Three types of systematic errors are found: Increasing and periodic offsets of the translation stage position, as well as a drift of its initial position in a series of consecutive measurements. The influence of the detected errors on the measured terahertz spectra is studied and correction methods are proposed.

Overview

CoChat Summary

TL;DR

The paper upgrades a terahertz time-domain spectroscopy optical delay line with an optical encoder to detect and correct translation-stage positioning errors. It identifies increasing, periodic, and initial-position drift errors, studies their spectral effects, and demonstrates encoder-based correction for the first two types.

Key findings

  • Three systematic delay-line errors were detected: an increasing position offset of tens of micrometers (example: 16 μm over 40 mm, slope α = −0.0004), a periodic error with 0.4–1 μm amplitude and 250 μm period, and an initial-position drift of about 1 μm (6.7 fs) that settled at −3.5 μm after more than five measurements.
  • The increasing offset stretched the time-domain signal by a factor of 1.0004, squeezing the spectrum; at 1 THz this corresponds to a 400 MHz shift, and the water-vapor line at 1.411 THz shifted by ~500 MHz. Corrected spectra were closer to HITRAN tabulated water absorption lines.
  • The periodic error produced spurious spectra around 600 GHz and harmonics, with amplitude on the order of ~10⁻³ compared to the main pulse spectrum near 600 GHz; for a 376 GHz bandpass filter, the spurious feature was ~580 times smaller than the main spectral feature.
  • Encoder-based correction using measured positions and interpolation removed the first two error types and mechanical screw defects; correction of the initial-position drift was proposed via software methods.

Methods

  • Experiments used a custom THz-TDS system with an Er-doped fiber laser (775 nm, 130 fs, 80 mW), a GaAs photoconductive antenna, ZnTe electro-optic detection, and a lock-in amplifier at ~8 kHz.
  • The delay line was an 8MT173-50-20 translation stage with a corner reflector, upgraded with a Renishaw Resolute RL32BAT001B50 optical encoder and RTLA scale; encoder specifications included 1 nm resolution, ±40 nm sub-divisional error, 0.5 μm absolute accuracy over a 10 cm scale, ±3.34 fs time-domain absolute accuracy, and ±0.27 fs random error.
  • Measurements were point-by-point at 12.5 μm steps over 45 mm at 0.78 mm/s with a 100 ms lock-in time constant; four analogous translation stages were compared, and both stepper-count position (L_st) and encoder position (L_en) were recorded. Correction associated each THz field sample with the encoder position and interpolated to restore equidistant sampling.

Limitations

  • Stated: the third-type initial-position drift appears due to heating of the stepper motor and translation stage platform and thermal expansion of the encoder scale; heating by 1 °C shifts the scale free end by ~1 μm, so setting the initial position from stepper-motor counts can be more accurate than from encoder data.
  • Stated: spurious spectra from the periodic error have amplitude comparable to the spectrometer signal-to-noise ratio, making them difficult to detect.
  • Evident from the text: correction is experimentally demonstrated for the first two error types, while correction of the initial-position drift is only proposed as a software method; drift measurements are reported for one translation stage in a series of ten consecutive measurements.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/electronics8121408

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

5 Valid · 0 Not valid · 7 Not checked · 40 Own results and interpretations

26 more claims

Create a free account to see all 52 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 6
  • It may state two separate claims as one. 15
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 27 references

Cited by

Metadata

Authors
Mamrashev, A., Minakov, F., Maximov, L., Nikolaev, N., & Chapovsky, P.
Affiliations
  • Institute of Automation and Electrometry (RU)
  • Novosibirsk State University (RU)
  • Russian Academy of Sciences (RU)
Corresponding author
Mamrashev, Alexander
Venue
Electronics
Publisher
MDPI AG
Published
2019-11-26
Volume
8
Issue
12
Pages
1408
ISSN
2079-9292 (ISSN-L)
OpenAlex
W2991265562
Cited by
20
References
27
Citations by year
2026: 3 · 2025: 2 · 2024: 5 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 4
Type
journal article
Language
en
Open access
Locations
Electronics (publishedVersion, cc-by)
Funders
Russian Science Foundation (17-12-01418)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
optical delay line, terahertz time-domain spectroscopy, optical encoder, position drift, waveform distortion, error correction, corner reflectors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.