The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Uncertainty and Ambiguity in Terahertz Parameter Extraction and Data Analysis
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“produces artifacts that can degrade the overall measurement quality and yield misleading results [4-13].”
From Maximum-likelihood parameter estimation in terahertz time-domain spectroscopy (2021) · cites this paper as [10]
In the citing paper
“The Fourier transform scrambles the THz-TDS measurement noise, which is more naturally represented in the time domain”
From Maximum-likelihood parameter estimation in terahertz time-domain spectroscopy (2021) · cites this paper as [10]
In the citing paper
“Errors in the positioning of the optical delay line lead to more complex distortions.”
From Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy (2019) · cites this paper as [11]
Citations
Cites
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
On the Theory of Dispersion of X-Rays
de L. Kronig, R. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000547 · Cited by 1,987
A reliable method for extraction of material parameters in terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571775 · Cited by 994
Material parameter estimation with terahertz time-domain spectroscopy
Dorney, T. D., Baraniuk, R. G., & Mittleman, D. M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001562 · Cited by 807
Picosecond optoelectronic switching and gating in silicon
Auston, D. H. (1975) · Applied Physics Letters · doi:10.1063/1.88079 · Cited by 768
Kindt, J. T., & Schmuttenmaer, C. A. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp960141g · Cited by 687
Exploring Dynamics in the Far-Infrared with Terahertz Spectroscopy
Schmuttenmaer, C. A. (2004) · Chemical Reviews · doi:10.1021/cr020685g · Cited by 659
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1999) · Applied Optics · doi:10.1364/ao.38.000409 · Cited by 505
Dai, J., Zhang, J., Zhang, W., & Grischkowsky, D. (2004) · Journal of the Optical Society of America B · doi:10.1364/josab.21.001379 · Cited by 499
Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling
Bartels, A., Cerna, R., Kistner, C., Thoma, A., Hudert, F., Janke, C., & Dekorsy, T. (2007) · Review of Scientific Instruments · doi:10.1063/1.2714048 · Cited by 460
Cited by
Phase Retrieval in Terahertz Time-Domain Measurements: a 'how to' Tutorial
Jepsen, P. U. (2019) · Journal of Infrared, Millimeter and Terahertz Waves · doi:10.1007/s10762-019-00578-0 · Cited by 114
Zaytsev, K. I., Gavdush, A. A., Chernomyrdin, N. V., & Yurchenko, S. O. (2015) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2015.2460677 · Cited by 89
“All these factors should be considered during solution of the inverse problem and estimation of the reconstruction error [28], [65].”
BackgroundData Extraction from Terahertz Time Domain Spectroscopy Measurements
Scheller, M. (2014) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-014-0053-4 · Cited by 75
“to employ the Kramers-Kronig relation (KKR) for overcoming ambiguities in the data extraction [11].”
MethodAccuracy of sample material parameters reconstruction using terahertz pulsed spectroscopy
Zaytsev, K. I., Gavdush, A. A., Karasik, V. E., Alekhnovich, V. I., Nosov, P. A., Lazarev, V. A., Reshetov, I. V., & Yurchenko, S. O. (2014) · Journal of Applied Physics · doi:10.1063/1.4876324 · Cited by 53
Metrology State-of-the-Art and Challenges in Broadband Phase-Sensitive Terahertz Measurements
Naftaly, M., Clarke, R. G., Humphreys, D. A., & Ridler, N. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2644108 · Cited by 49
Metadata
- Authors
- Krüger, M., Funkner, S., Bründermann, E., & Havenith, M.
- Affiliations
- Ruhr University Bochum (DE)
- Corresponding author
- Havenith, Martina
- Venue
- Journal of Infrared, Millimeter, and Terahertz Waves
- Published
- 2010-07-04
- Volume
- 32
- Issue
- 5
- Pages
- 699-715
- ISSN
- 1866-6892 (ISSN-L)
- 1866-6906
- OpenAlex
- W2039429129
- Cited by
- 43
- References
- 39
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 3 · 2017: 5 · 2016: 3 · 2015: 4 · 2014: 4 · 2013: 6
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Infrared Millimeter and Terahertz Waves (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Keywords
- terahertz time-domain spectroscopy, parameter extraction, error propagation, Fourier transform, absorption coefficient, refractive index, dispersive Fourier transform spectroscopy, anthracene, capric acid, ionic liquids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uncertainty and Ambiguity in Terahertz Parameter Extraction and Data Analysis. https://app.cochat.ai/papers/10.1007/s10762-010-9669-1
- The paper
- Krüger, M., Funkner, S., Bründermann, E., & Havenith, M. (2011). Uncertainty and Ambiguity in Terahertz Parameter Extraction and Data Analysis. Journal of Infrared, Millimeter, and Terahertz Waves. https://doi.org/10.1007/s10762-010-9669-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.