Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review
Open accessThe DOI matches its Crossref record; 306 of the 315 references it cites were found in a registry or an index.
Abstract
Power systems are the most complex systems that have been created by men in history. To operate such systems in a stable mode, several control loops are needed. Voltage frequency plays a vital role in power systems which need to be properly controlled. To this end, primary and secondary frequency control loops are used to control the frequency of the voltage in power systems. Secondary frequency control, which is called Load Frequency Control (LFC), is responsible for maintaining the frequency in a desirable level after a disturbance. Likewise, the power exchanges between different control areas are controlled by LFC approaches. In recent decades, many control approaches have been suggested for LFC in power systems. This paper presents a comprehensive literature survey on the topic of LFC. In this survey, the used LFC models for diverse configurations of power systems are firstly investigated and classified for both conventional and future smart power systems. Furthermore, the proposed control strategies for LFC are studied and categorized into different control groups. The paper concludes with highlighting the research gaps and presenting some new research directions in the field of LFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 Comparison between different objective functions, i.e., IAE, ISE, ITAE, and ITSE: ( a ) frequency deviations in different control areas; ( b ) frequency overshoot; and ( c ) frequency settling time. IAE: Integral of absolute error; ISE: integral of squared error; ITAE: integral of time multiplied by absolute error; ITSE: integral of time multiplied by squared error [295].](https://figures.cochat.ai/paper-figures/5088e2370d0d492690748566492ddd25/challenges-and-opportunities-of-load-frequency-control-in-conventional-modern-figure-4.png)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A power system's operational point may eventually experience variations from the nominal system frequency and planned power exchanges to other places, which could have a negative impact [75].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
The cited source says what the claim attributes to it.
In the citing paper
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223
Shamseer, L., Moher, D., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., Stewart, L. A., & the PRISMA-P Group (2015) · BMJ · doi:10.1136/bmj.g7647 · Cited by 13,120
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Demand Side Management: Demand Response, Intelligent Energy Systems, and Smart Loads
Palensky, P., & Dietrich, D. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2158841 · Cited by 2,927
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
(2009) · Cited by 2,062
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Robust Power System Frequency Control
Bevrani, H. (2009) · Springer eBooks · doi:10.1007/978-0-387-84878-5 · Cited by 1,164 · cited 3×
“LFC schemes for hydro power systems under deregulation are presented in [101,102].”
BackgroundMethodKirkham, J. J., Dwan, K. M., Altman, D. G., Gamble, C., Dodd, S., Smyth, R., & Williamson, P. R. (2010) · BMJ · doi:10.1136/bmj.c365 · Cited by 1,133
Kanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985
Research works printed but not linked: 14
- Concordia, C.; Kirchmayer, L. Tie-line power and frequency control of electric power systems-Part II. Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst. 1954, 73, 133-146.
- Concordia, C.; Kirchmayer, L. Tie-line power and frequency control of electric power systems. Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst. 1953, 72, 562-572.
- Chokpanyasuwan, C. (2008, January 12–14). Robot Fuzzy logic-PID Controller for Wind-Diesel Power System using Particle Swarm Optimization. Proceedings of the GMSARN International Conference on Sustainable Development: Issues and Prospects for the GMS, Kunming, China.
- Hilloowala, R.M., and Sharaf, A.M. (1993, January 2–8). A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme. Proceedings of the Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting, Toronto, ON, Canada.
- Lasseter, R.H. (2002, January 27–31). Microgrids. Proceedings of the Power Engineering Society Winter Meeting, New York, NY, USA.
- Lakshmi, 2014, Pso based load frequency control for single area power system, Int. J. Sci. Eng. Res., 5, 12
- Velusami, 1997, Design of observer-based decentralized load-frequency controllers for interconnected power systems, Int. J. Power Energy Syst., 17, 152
- Feliachi, 1987, Load frequency control using reduced order models and local observers, Int. J. Energy Syst., 7, 72
- Rao, C.S. (2012, January 30–31). Adaptive Neuro Fuzzy based Load Frequency Control of multi area system under open market scenario. Proceedings of the 2012 International Conference on Advances in Engineering, Science and Management (ICAESM), Nagapattinam, India.
- Karrari, 1999, Design of H∞ controller load frequency control in electrical power systems, Amirkabir J. Sci. Technol., 11, 79
- Bevrani, H. (1999, January 22–27). Robust load frequency controller in a deregulated environment: A/spl mu/-synthesis approach. Proceedings of the 1999 IEEE International Conference on Control Applications, Kohala Coast, HI, USA.
- Bensenouci, A., and Ghany, A.A. (2007, January 9–12). Mixed H∞/H2 with pole-placement design of robust LMI-based output feedback controllers for multi-area load frequency control. Proceedings of the International Conference on “Computer as a Tool” (EUROCON 2007), Warsaw, Poland.
- Chidambaram, 2009, Genetic algorithm based decentralized controller for load-frequency control of interconnected power systems with RFB considering TCPS in the tie-line, Int. J. Electron. Eng. Res., 1, 299
- Balasundaram, 2012, ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB, Int. J. Eng. Innov. Technol., 1, 1
Cited by
Items 101–200 of 349
Shayeghi, H., Rahnama, A., Mohajery, R., Bizon, N., Mazare, A. G., & Ionescu, L. M. (2022) · Electronics · doi:10.3390/electronics11213440 · Cited by 23
A Novel Swarm Approach for Regulating Load Frequency in Two-Area Energy Systems
Nireekshana, N., Ramachandran, R., & Narayana, G. V. (2023) · International Journal of Electrical and Electronics Research · doi:10.37391/ijeer.110218 · Cited by 22
“In such a case, load frequency control optimization approaches are employed to ensure the reliability and quality of operation in a system of frequency, tie line power flow and calculate net changes means Area Control Error[14], [17].”
BackgroundMethodInfluentialMarkov, K. K., & Rajaković, N. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.05.048 · Cited by 22
Singh, A., Shankar, R., & Kumar, A. (2025) · Energies · doi:10.3390/en18040843 · Cited by 21
A State-of-the-Art Review on LFC Strategies in Conventional and Modern Power Systems
Shouran, M., Anayi, F., & Packianather, M. (2021) · International Conference on Advance Computing and Innovative Technologies in Engineering (ICACITE) · doi:10.1109/icacite51222.2021.9404653 · Cited by 21
Extending SFR model to incorporate the influence of thermal states on primary frequency response
Cao, Y., Zhang, H., Zhang, Y., Xie, Y., & Ma, C. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2020.0206 · Cited by 22
“governor dead-band and generation rate constraint, should be considered [27].”
BackgroundOptimal Frequency Regulation in AC Mobile Power Grids Exploiting Bilinear Matrix Inequalities
Javanmardi, H., Dehghani, M., Mohammadi, M., Vafamand, N., & Dragičević, T. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3064864 · Cited by 21
“The challenges and opportunities of the secondary LFC are reviewed in [9].”
BackgroundKumar, A., Khadanga, R. K., & Panda, S. (2021) · Soft Computing · doi:10.1007/s00500-021-06558-8 · Cited by 20
“Another way to handle the LFC issue is to employ a natureinspired technique-based design methodology that can successfully be utilized to manage the nonlinearities in the LFC problem (Alhelou et al. 2018).”
MethodŞahin, E., & Çavdar, B. (2025) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2025.110240 · Cited by 24
Bilateral Contract for Load Frequency and Renewable Energy Sources Using燗dvanced Controller
Arora, K., Joshi, G. P., Ragab, M., Rawa, M. J. H., Milyani, A. H., Mansour, R. F., & Yang, E. (2022) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.026966 · Cited by 18
Yousef, M. Y., Mosa, M. A., Ali, A. A., Ghany, A. M. A., & Ghany, Α. M. A. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2023.109352 · Cited by 17
Zhang, Z., Hu, J., Lu, J., Yu, J., Cao, J., & Kashkynbayev, A. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2023.000400 · Cited by 17
Ahmed, I., Adnan, M., Iqbal, S., Raza, A., Hassan, W., & Mohamed, S. E. G. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.103004 · Cited by 20
Assessing the optimal generation technology mix determination considering demand response and EVs
Alhelou, H. H., Mirjalili, S. J., Zamani, R., & Siano, P. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105871 · Cited by 16
Self-citationSingh, B., Słowik, A., & Bishnoi, S. K. (2023) · Energies · doi:10.3390/en16041917 · Cited by 22
An Improved Stability Criterion for Load Frequency Control of Power Systems with Time-Varying Delays
Chen, B.-Y., Shangguan, X., Jin, L., & Li, D. (2020) · Energies · doi:10.3390/en13082101 · Cited by 16
A Peer Survey on Load Frequency Contol in Isolated Power System with Novel Topologies
Nireekshana, N. (2021) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.a3124.1011121 · Cited by 15
“To bring the frequency under one palm in all areas of this interconnected system, LFC will be adopted few control strategies[10] [28].”
BackgroundMethodInfluentialSmart Home Energy Management System
Molla, T. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch011 · Cited by 15
Recent Strategies for Automatic Generation Control of Power Systems With Diverse Energy Sources
Kumar, A., & Singh, O. (2021) · International Journal of System Dynamics Applications · doi:10.4018/ijsda.20211001.oa8 · Cited by 15
“…Proportional Integral (PI), PID and Proportional Integral Double Derivative (PIDD) controllers to control frequency and tie-line power flow, optimal control method, adaptive control system, intelligent control like FLA, AI based control and SC for AGC with various algorithms (Alhelou et al., 2018).”
Torabi-Farsani, K., Vafamand, N., Razavi‐Far, R., & Saif, M. (2022) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2022.108008 · Cited by 15
Aluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2021) · Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA) · doi:10.1109/saupec/robmech/prasa52254.2021.9377015 · Cited by 14
“Interested readers can find a detailed review of various LFC schemes for traditional and modern power systems that are presented in [6], [7].”
BackgroundDual‐mode control of utility interactive microgrid
Kumar, S., & Singh, B. (2019) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.6087 · Cited by 14
“A comprehensive review on load frequency control and challenges are reported in [8].”
BackgroundCascade of Fractional Order PID based PSO Algorithm for LFC in Two-Area Power System
Shouran, M., & Alsseid, A. M. (2021) · International Conference on Electronics Representation and Algorithm (ICERA) · doi:10.1109/icera53111.2021.9538646 · Cited by 16
Al-Majidi, S. D., Altai, H. D. S., Lazim, M. H., Al-Nussairi, M. K., Abbod, M., & Al-Raweshidy, H. S. (2023) · Energies · doi:10.3390/en16062802 · Cited by 14
Simpson-Porco, J. W., & Monshizadeh, N. (2021) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2021.3113266 · Cited by 14
Analysis and Proposed Remedies for Power System Blackouts around the Globe
Raza, M. A., Khatri, K. L., Hussain, A., Khan, M. M. H., Shah, A., & Taj, H. (2022) · International Electrical Engineering Conference (IEEC) · doi:10.3390/engproc2022020005 · Cited by 14
“Failure of control and protection systems, transmission line tripping or overloading, poor maintenance, lightning strikes, human mistakes, voltage collapse, equipment malfunction, cyberattacks, and other factors all contribute to power system blackouts [1].”
BackgroundPMU Placement with Multi-Objective Optimization Considering Resilient Communication Infrastructure
Cruz, M. A. R. S., Rocha, H. R. O., Paiva, M. H. M., Silva, J. A. L., Camby, E., & Segatto, M. E. V. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108167 · Cited by 13
Dao, T. T., Tran, A. N., Huynh, V. V., & Duc, T. (2025) · IEEE Access · doi:10.1109/access.2025.3532516 · Cited by 13
“In multi-area electrical power systems (EPSs), keeping frequency stability is a critical task to ensure the reliable grid’s operation [1], [2].”
Reliable Electricity Generation in RES-Based Microgrids
Kharchenko, V. V., Gusarov, V. A., & Bolshev, V. E. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch006 · Cited by 13
Ochoa-Correa, D., & Martínez, S. (2021) · Energies · doi:10.3390/en14123660 · Cited by 15
“In [11], an exhaustive literature review on the topic of LFC addressing its challenges and opportunities in conventional, modern and future power systems is presented.”
BackgroundKhadanga, R. K., Nayak, S. R., Panda, S., Das, D., Prusty, B. R., & Sahu, P. R. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/6017066 · Cited by 13
“Te primary goal of EA is for them to be able to manage nonlinear functions [21].”
BackgroundPerformance of fast responding ultracapacitor energy storage for virtual inertia emulation control
Mahajan, S., & Verma, Y. P. (2022) · Energy Storage · doi:10.1002/est2.346 · Cited by 15
A Framework for $$H_{2} /H_\infty$$ Synthesis in Damping Power Network Oscillations with STATCOM
Devarapalli, R., & Bhattacharyya, B. (2019) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-019-00278-4 · Cited by 12
Kumar, R., & Sharma, V. K. (2023) · Electrical Engineering · doi:10.1007/s00202-023-02043-7 · Cited by 12
“Thisleadstointerconnectedsystems[2],wherethepower generated in several areas is connected by the tie line [3] to supply a common load.”
Economic operation of islanded micro-grids via modified active disturbance rejection control
Wu, Z., Liu, Y., Chen, P., & Chen, Y. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109974 · Cited by 12
Ghany, Α. M. A., Syam, F. A., Aly, A. M., Abido, M. A., & Ibrahim, S. O. (2024) · Journal of Electrical Systems and Information Technology · doi:10.1186/s43067-024-00173-x · Cited by 12
Ali, H. H., Fathy, A., Al‐Shaalan, A. M., Kassem, A. M., Farh, H. M. H., Al-Shamma’a, A. A., & Gabbar, H. A. (2021) · Energies · doi:10.3390/en14175393 · Cited by 12
“In the deregulated system, control is highly decentralized and independent system operators (ISOs) are responsible for keeping the steady frequency and tie-line power flow within their acceptable limits [4,5].”
BackgroundDesign and Prototyping of Electronic Load Controller for Pico Hydropower System
Praptodiyono, S., Maghfiroh, H., Nizam, M., Hermanu, C., & Wibowo, A. (2021) · Jurnal Ilmiah Teknik Elektro Komputer dan Informatika · doi:10.26555/jiteki.v7i3.22271 · Cited by 12
Xiong, J., Ding, Y., Ye, H., Pei, W., & Kong, L. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.08.098 · Cited by 12
Adaptive Automatic Voltage Regulation in Rural 0.38 kV Electrical Networks
Vinogradov, A., Васильевна, В. А., Golikov, I., & Bolshev, V. E. (2019) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2018-0269 · Cited by 12
Mohanty, P., Sahu, R. K., Pradhan, P. C., & Panda, S. (2021) · International Journal of Ambient Energy · doi:10.1080/01430750.2021.1909134 · Cited by 11
“The sys-tem’sfrequencyisbasedonthebalancebetweenrealpowerand demand (Pandey, Mohanty, and Kishor 2013; Shayeghi, Shayan-far, and Jalili 2009; Hassan et al. 2018).”
Ghany, Α. M. A., Mosa, M. A., Ghany, A. M. A., & Yousef, M. Y. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110368 · Cited by 11
Meseret, G. M., Kumhar, R., Mahato, T. K., Lakra, P., Kumari, B., & Kumar, N. (2025) · Engineering Reports · doi:10.1002/eng2.70054 · Cited by 11
“The literature review states that triangle MFs are the favored option because they are simple to implement using a FIS, use less memory, and are easy to create for real-time applications Tasnin and Saikia, [29].”
Wu, Z., Li, P., Liu, Y., Li, D., & Chen, Y. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.08.035 · Cited by 11
Mohammed, A. J., Al-Majidi, S. D., Al-Nussairi, M. K., Abbod, M., & Al-Raweshidy, H. S. (2022) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec55022.2022.9917853 · Cited by 11
“Hence, an unstable frequency level is happened when the power generation units is not adjusted with the connectedload [1][2][3][4].”
BackgroundChinta, D. P., Jatoth, R. K., & Biswal, M. (2023) · Journal of Engineering Research · doi:10.1016/j.jer.2023.100116 · Cited by 11
Power Quality of Electrical Power Systems
Mahfoud, F., Guzun, B. D., Lăzăroiu, G. C., & Alhelou, H. H. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch011 · Cited by 11
Self-citationUnder Frequency Load Shedding Techniques for Future Smart Power Systems
Alhelou, H. H. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch007 · Cited by 11
Self-citationRanjitha, K. R., Sivakumar, P., & Monica, M. (2022) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-07-2021-0231 · Cited by 11
Analysis of Power Swings and Blackouts
Desai, J. P. (2021) · doi:10.1109/ingelectra54297.2021.9748070 · Cited by 11
Direct Participation of Dynamic Virtual Power Plants in Secondary Frequency Control
Adabi, M. E., & Marinescu, B. (2022) · Energies · doi:10.3390/en15082775 · Cited by 10
Frequency control enhancement of an islanded microgrid using disturbance-observer-based approach
Aggarwal, N., Mahajan, A. N., & Nagpal, N. (2024) · International Journal of Electronics · doi:10.1080/00207217.2024.2312555 · Cited by 10
“The design procedure of a robust stochastic disturbance observer along with optimal observer gain, L d is referred from the work (Alhelou et al., 2018).”
InfluentialUpadhaya, D., Biswas, S., Dutta, S., & Bhattacharya, A. (2024) · Renewable energy focus · doi:10.1016/j.ref.2024.100676 · Cited by 10
Liu, Y., Xu, D., Lee, S., & Zhang, X. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3593376 · Cited by 10
Makdisie, C. J., & Mariam, M. F. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch018 · Cited by 10
Kumar, N. M., & Chopra, S. S. (2023) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2023.103209 · Cited by 13
Wide-Area Measurement Systems and Phasor Measurement Units
Maheswari, M., Vanitha, N. S., & Loganathan, N. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_4 · Cited by 10
Pradhan, P. C., Sahu, R. K., & Panda, S. (2021) · Journal of Electrical Systems and Information Technology · doi:10.1186/s43067-021-00033-y · Cited by 10
Kumar, M., & Hote, Y. V. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2020.0618 · Cited by 9
Shouran, M., Anayi, F., & Packianather, M. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.10.322 · Cited by 14
Improved Model-Free Adaptive Load Frequency Control for Multi-Area Power Systems
Chen, J., Gong, D., Zhao, Y., Song, S., & Zhu, M. (2025) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2025.3598338 · Cited by 8
“L OAD frequency fluctuation is a common issue that affects the secure and stable operation of power systems [1], [2].”
Barakat, M., Salama, G. M., Donkol, A. A. E.-B., & Hamed, H. F. A. (2021) · Journal of Advanced Engineering Trends · doi:10.21608/jaet.2021.64407.1090 · Cited by 8
Design of support vector machine controller for hybrid power system automatic generation control
Appikonda, P., & Kasibhatla, R. S. (2022) · Energy Sources Part A Recovery Utilization and Environmental Effects · doi:10.1080/15567036.2022.2070302 · Cited by 8
“(Alhelou et al. 2018) for the suppression of the oscillations in frequency and inter-area power transfer and to keep good tracking of load fluctuations and disturbances.”
BackgroundAn Overview of Wide Area Measurement System and Its Application in Modern Power Systems
Alhelou, H. H. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch012 · Cited by 8
Self-citationSectionalizing and Redundancy of the 0.38 kV Ring Electrical Network
Vinogradov, A., Васильевна, В. А., Bolshev, V. E., & Psarev, A. I. (2019) · International Journal of Energy Optimization and Engineering · doi:10.4018/ijeoe.2019100102 · Cited by 8
Introduction to Electric Distribution System
Sivaraman, P., & Chenniappan, S. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch001 · Cited by 9
Zamani, R., Moghaddam, M. P., Imani, M., Alhelou, H. H., Golshan, M. E. H., & Siano, P. (2019) · doi:10.1109/ptc.2019.8810466 · Cited by 8
Self-citationNayak, A., Maharana, M. K., Sidhu, T. S., Padmanaban, S., & Panda, G. (2022) · Energy Sources Part A Recovery Utilization and Environmental Effects · doi:10.1080/15567036.2022.2115581 · Cited by 8
“Many significant contributions to the issues and challenges related to LFC considering standard system models have been made before (Alhelou et al. 2018).”
BackgroundZeng, Y., Bu, X., & Yin, Y. (2025) · Asian Journal of Control · doi:10.1002/asjc.3481 · Cited by 7
Meseret, G. M., Kumhar, R., Mahato, T. K., Kumar, N., Lakra, P., & Alam, M. (2025) · Engineering Reports · doi:10.1002/eng2.70160 · Cited by 7
“The primary benefit of Neuro-Fuzzy interfaces over fuzzy-based design is that fewer membership functions are needed to describe the same number of rules [35].”
AboRas, K. M., Elkassas, A. M., Megahed, A. I., & Kotb, H. (2025) · Mathematics · doi:10.3390/math13142251 · Cited by 7
Asad, M., Faizan, M., Zanchetta, P., & Sánchez, J. A. (2025) · Applied Sciences · doi:10.3390/app15148039 · Cited by 7
Discrete optimal quadratic AGC based cost functional minimization for interconnected power systems
Esmail, M., & Krishnamurthy, S. (2023) · Scientific Reports · doi:10.1038/s41598-023-29317-1 · Cited by 7
Feleke, S., Pydi, B., Satish, R., Anteneh, D., AboRas, K. M., Kotb, H., Alharbi, M., & Abuagreb, M. (2023) · Sustainability · doi:10.3390/su15075625 · Cited by 7
A novel predictive optimal control strategy for renewable penetrated interconnected power system
Kumar, V., Sharma, V., Naresh, R., & Arya, Y. (2024) · Optimal Control Applications and Methods · doi:10.1002/oca.3144 · Cited by 7
Application of AGPSO Algorithm in Frequency Controller Design for Isolated Microgrid
Kumar, M., Agrawal, S., & Mohamed, T. H. (2021) · IEEE Texas Power and Energy Conference (TPEC) · doi:10.1109/tpec51183.2021.9384910 · Cited by 7
“In the literature, researchers have preferred PID control design for frequency control of the microgrid systems [4].”
BackgroundMethodInfluentialA neoteric closed loop feedback controller based on correlative-elemental curvature algorithm
Das, N. K., & Buragohain, M. (2021) · Circuit World · doi:10.1108/cw-06-2020-0107 · Cited by 7
Fliess, M., Join, C., & Sauter, D. (2021) · International Conference on Control and Fault-Tolerant Systems (SysTol) · doi:10.1109/systol52990.2021.9595717 · Cited by 8
Home Load-Side Management in Smart Grids Using Global Optimization
Recioui, A. (2021) · IGI Global eBooks · doi:10.4018/978-1-7998-8048-6.ch051 · Cited by 7
Cao, G., Zhang, X., Li, P., Li, F., Liu, Y., & Wu, Z. (2023) · Energy Reports · doi:10.1016/j.egyr.2023.04.379 · Cited by 7
Dekaraja, B., & Saikia, L. C. (2023) · Energy Storage · doi:10.1002/est2.505 · Cited by 7
Bidgoli, M. A., Ganjali, D., Yang, W., & Atrian, S. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_9 · Cited by 7
Introduction to Smart Grid and Micro-Grid Systems
Nadweh, S., & Barakat, Z. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch015 · Cited by 6
Recent Strategies for Automatic Generation Control of Multi-Area Interconnected Power Systems
Kumar, A., & Singh, O. (2019) · International Conference on Recent Developments in Control, Automation & Power Engineering (RDCAPE) · doi:10.1109/rdcape47089.2019.8979071 · Cited by 6
Dekaraja, B., Saikia, L. C., & Ramoji, S. K. (2023) · Energy Storage · doi:10.1002/est2.457 · Cited by 6
“39 to design secondary controller.”
Existing Issues Associated With Electric Distribution System
Sivaraman, P., & Chenniappan, S. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch002 · Cited by 6
“…are mostly standby generators and it will be in operation only if power grid supply is not available (Alhelou et al., 2019; Makdisie et al., 2018; Alhelou et al., 2018; Alhelou et al., 2016; 33 Existing Issues Associated With Electric Distribution System Haes Alhelou et al., 2019; Njenda et al.,…”
BackgroundDekaraja, B., Saikia, L. C., & Ramoji, S. K. (2022) · International Conference on Intelligent Controller and Computing for Smart Power (ICICCSP) · doi:10.1109/iciccsp53532.2022.9862433 · Cited by 6
“Simulate annealing [9], lightning search algorithm [11], moth flame optimization [10], [18], and artificial flora algorithm (AFA) [12] has been already implemented efficiently in unified ALFC-AVR system.”
MethodAraúz, J., & Martínez, S. (2023) · IEEE Access · doi:10.1109/access.2023.3279499 · Cited by 6
Load Frequency Control of Single Area Hybrid Power System Using Fuzzy-PID (FPID) Controller
Singh, A. K., Ahmad, P., Singh, N. K., & Choudhary, N. K. (2019) · Students Conference on Engineering and Systems · doi:10.1109/sces46477.2019.8977216 · Cited by 6
“The load frequency control is one of the classical power system problems [1].”
BackgroundOptimal Automatic Generation Control in Multi-Area Power Systems with Diverse Energy Sources
Kumar, A., & Singh, O. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-1476-7_27 · Cited by 6
Niyomsat, T., & Puangdownreong, D. (2019) · Artificial Intelligence and Cloud Computing Conference (AICCC) · doi:10.1145/3375959.3375963 · Cited by 6
“Various advanced control strategies were consecutively proposed in literatures [4],[5], such as, optimal control [6], sliding mode control [7], internal model control [8], integer-order proportional-integralderivative (IOPID) control [9],[10] and fuzzy control [11].”
BackgroundAlhelou, H. H., Bahrani, B., & Ma, J. (2024) · IEEE Transactions on Energy Markets Policy and Regulation · doi:10.1109/tempr.2024.3421888 · Cited by 6
“Interested readers are referred to the comprehensive review, by Alhelou et al., [17], [18] for more details in the different methods and their challenges and opportunities.”
Self-citationMohanty, P., Sahu, R. K., Pradhan, P. C., Samal, N. R., & Panda, S. (2022) · International Journal of Ambient Energy · doi:10.1080/01430750.2022.2068066 · Cited by 5
“Controllers are provided to preserve the equilibrium between powergenerationandload(Bevrani2009;Pandey,Mohanty,and Kishor 2013; Nanda, Mangla, and Suri 2006; Shayeghi, Shayanfar, and Jalili 2009; Hassan et al. 2018).”
Shahgholian, G., & Fathollahi, A. (2024) · AppliedMath · doi:10.3390/appliedmath4020024 · Cited by 5
Park, H. Y., & Kim, J. H. (2022) · IEEE Access · doi:10.1109/access.2022.3222487 · Cited by 5
“More importantly, we would like to note that the ACE, which is often taken as an output in LFC of power systems [4], [5], [6], is affected by the tie-line power deviation”
BackgroundOptimal Solution of Environmental Economic Dispatch Problems Using QPGPSO-ω
Salaria, U. A., Menhas, M. I., Manzoor, S., Butt, F. M., Ellahi, M., Ali, N., Orazbekov, Z., & Mohamed, H. G. (2023) · Applied Sciences · doi:10.3390/app13126867 · Cited by 5
Migisha, A. G., Ntayi, J. M., Adaramola, M. S., Buyinza, F., Senyonga, L., & Abaliwano, J. (2023) · Technological Sustainability · doi:10.1108/techs-08-2023-0030 · Cited by 5
Bu, X., Zeng, Y., Yin, Y., & Liang, J. (2024) · Journal of Renewable and Sustainable Energy · doi:10.1063/5.0168895 · Cited by 5
Probabilistic decentralised control and message passing framework for future grid
Herzallah, R., & Zhou, Y. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107114 · Cited by 5
Economic Operation of Smart Micro-Grid
Khan, B., & Singh, P. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch055 · Cited by 5
Metadata
- Authors
- Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P.
- Affiliations
- Latakia University (SY)
- Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- Isfahan University of Technology (IR)
- Esfahan Electricity Power Distribution Company (EEPDC), Isfahan 81737-51387, Iran
- University of Salerno (IT)
- Corresponding author
- Siano, Pierluigi
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2018-09-20
- Volume
- 11
- Issue
- 10
- Pages
- 2497
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2890216498
- Cited by
- 349
- References
- 315
- Citations by year
- 2026: 15 · 2025: 33 · 2024: 35 · 2023: 47 · 2022: 41 · 2021: 69 · 2020: 41 · 2019: 62 · 2018: 6
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Keywords
- load frequency control, secondary frequency control, primary frequency control, power system frequency stability, smart power systems, control strategy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.