Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review
Open accessThe DOI matches its Crossref record; 306 of the 315 references it cites were found in a registry or an index.
Abstract
Power systems are the most complex systems that have been created by men in history. To operate such systems in a stable mode, several control loops are needed. Voltage frequency plays a vital role in power systems which need to be properly controlled. To this end, primary and secondary frequency control loops are used to control the frequency of the voltage in power systems. Secondary frequency control, which is called Load Frequency Control (LFC), is responsible for maintaining the frequency in a desirable level after a disturbance. Likewise, the power exchanges between different control areas are controlled by LFC approaches. In recent decades, many control approaches have been suggested for LFC in power systems. This paper presents a comprehensive literature survey on the topic of LFC. In this survey, the used LFC models for diverse configurations of power systems are firstly investigated and classified for both conventional and future smart power systems. Furthermore, the proposed control strategies for LFC are studied and categorized into different control groups. The paper concludes with highlighting the research gaps and presenting some new research directions in the field of LFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 Comparison between different objective functions, i.e., IAE, ISE, ITAE, and ITSE: ( a ) frequency deviations in different control areas; ( b ) frequency overshoot; and ( c ) frequency settling time. IAE: Integral of absolute error; ISE: integral of squared error; ITAE: integral of time multiplied by absolute error; ITSE: integral of time multiplied by squared error [295].](https://figures.cochat.ai/paper-figures/5088e2370d0d492690748566492ddd25/challenges-and-opportunities-of-load-frequency-control-in-conventional-modern-figure-4.png)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A power system's operational point may eventually experience variations from the nominal system frequency and planned power exchanges to other places, which could have a negative impact [75].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
The cited source says what the claim attributes to it.
In the citing paper
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223
Shamseer, L., Moher, D., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., Stewart, L. A., & the PRISMA-P Group (2015) · BMJ · doi:10.1136/bmj.g7647 · Cited by 13,120
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Demand Side Management: Demand Response, Intelligent Energy Systems, and Smart Loads
Palensky, P., & Dietrich, D. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2158841 · Cited by 2,927
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
(2009) · Cited by 2,062
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Robust Power System Frequency Control
Bevrani, H. (2009) · Springer eBooks · doi:10.1007/978-0-387-84878-5 · Cited by 1,164 · cited 3×
“LFC schemes for hydro power systems under deregulation are presented in [101,102].”
BackgroundMethodKirkham, J. J., Dwan, K. M., Altman, D. G., Gamble, C., Dodd, S., Smyth, R., & Williamson, P. R. (2010) · BMJ · doi:10.1136/bmj.c365 · Cited by 1,133
Kanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985
Research works printed but not linked: 14
- Concordia, C.; Kirchmayer, L. Tie-line power and frequency control of electric power systems-Part II. Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst. 1954, 73, 133-146.
- Concordia, C.; Kirchmayer, L. Tie-line power and frequency control of electric power systems. Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst. 1953, 72, 562-572.
- Chokpanyasuwan, C. (2008, January 12–14). Robot Fuzzy logic-PID Controller for Wind-Diesel Power System using Particle Swarm Optimization. Proceedings of the GMSARN International Conference on Sustainable Development: Issues and Prospects for the GMS, Kunming, China.
- Hilloowala, R.M., and Sharaf, A.M. (1993, January 2–8). A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme. Proceedings of the Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting, Toronto, ON, Canada.
- Lasseter, R.H. (2002, January 27–31). Microgrids. Proceedings of the Power Engineering Society Winter Meeting, New York, NY, USA.
- Lakshmi, 2014, Pso based load frequency control for single area power system, Int. J. Sci. Eng. Res., 5, 12
- Velusami, 1997, Design of observer-based decentralized load-frequency controllers for interconnected power systems, Int. J. Power Energy Syst., 17, 152
- Feliachi, 1987, Load frequency control using reduced order models and local observers, Int. J. Energy Syst., 7, 72
- Rao, C.S. (2012, January 30–31). Adaptive Neuro Fuzzy based Load Frequency Control of multi area system under open market scenario. Proceedings of the 2012 International Conference on Advances in Engineering, Science and Management (ICAESM), Nagapattinam, India.
- Karrari, 1999, Design of H∞ controller load frequency control in electrical power systems, Amirkabir J. Sci. Technol., 11, 79
- Bevrani, H. (1999, January 22–27). Robust load frequency controller in a deregulated environment: A/spl mu/-synthesis approach. Proceedings of the 1999 IEEE International Conference on Control Applications, Kohala Coast, HI, USA.
- Bensenouci, A., and Ghany, A.A. (2007, January 9–12). Mixed H∞/H2 with pole-placement design of robust LMI-based output feedback controllers for multi-area load frequency control. Proceedings of the International Conference on “Computer as a Tool” (EUROCON 2007), Warsaw, Poland.
- Chidambaram, 2009, Genetic algorithm based decentralized controller for load-frequency control of interconnected power systems with RFB considering TCPS in the tie-line, Int. J. Electron. Eng. Res., 1, 299
- Balasundaram, 2012, ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB, Int. J. Eng. Innov. Technol., 1, 1
Cited by
Items 201–300 of 349
Optimal frequency regulation in an uncertain islanded microgrid: A modified direct search algorithm
Abolpour, R., Javanmardi, H., Dehghani, M., & Hesamzadeh, M. R. (2022) · IET Renewable Power Generation · doi:10.1049/rpg2.12427 · Cited by 5
Hamdy, A., Kamel, S. M., Nasrat, L., & Jurado, F. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_11 · Cited by 5
Liu, C., Shi, K., Cai, X. H., Zhu, M. Q., Yan, H., & Kwon, O. (2025) · International Journal of Control Automation and Systems · doi:10.1007/s12555-024-1140-5 · Cited by 4
“However, because of the complexity of power grid operation and the limitations of the control strategies currently implemented, the interconnected power grid may spread to a wider range and cause great harm when the fault occurs, which greatly restricts the social development [3-5].”
Halim, Y. M. A., Omar, O. A. M., Attia, M. A., Diaaeldin, I. M., Badr, A. O., & Afifi, M. A. (2025) · Scientific Reports · doi:10.1038/s41598-025-21454-z · Cited by 4
Araúz, J., & Martínez, S. (2024) · IEEE Access · doi:10.1109/access.2024.3396331 · Cited by 5
“This frequency control is widely studied in literature: [15] evaluates the evolution of secondary frequency control in future power systems and highlights how thermal loads and electric vehicles have the potential to contribute through microgrids and smart grids; [16] presents a secondary frequency…”
BackgroundMukherjee, M., & Banerjee, A. (2024) · International Journal of Information Technology · doi:10.1007/s41870-024-02222-0 · Cited by 4
Integral Reinforcement Learning-Based Adaptive Optimal Automatic Generation Control
Ou, R., Xu, Y., Li, Z., Hu, R., Huang, J., & Yu, J. (2021) · International Conference on Energy, Electrical and Power Engineering (CEEPE) · doi:10.1109/ceepe51765.2021.9475666 · Cited by 4
Smart Home Energy Management System
Molla, T. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch051 · Cited by 4
Gautam, M., MansourLakouraj, M., Hossain, R., Bhusal, N., Benidris, M., & Livani, H. (2024) · IEEE Access · doi:10.1109/access.2024.3349406 · Cited by 4
Load frequency control of a photovoltaic-pumped hydro power energy storagebased micro-grid System
Lalparmawii, R., Datta, S., Deb, S., & Das, S. (2021) · IEEE International Conference on Communication Systems and Network Technologies (CSNT) · doi:10.1109/csnt51715.2021.9509711 · Cited by 4
Jalendra, M., Reddy, K. S. G., Lavanya, M., Jaideep, N. V., Kalyan, C. N. S., & Suresh, C. V. (2022) · International Conference on Knowledge Engineering and Communication Systems (ICKECS) · doi:10.1109/ickecs56523.2022.10060567 · Cited by 4
Shaharear, M. A., Zhou, C., Shaikh, S., & Faruk, M. M. H. (2026) · Applied System Innovation · doi:10.3390/asi9030059 · Cited by 3
Venkatanagaraju, K., & Biswal, M. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch001 · Cited by 3
Ali, I., Askir, A., & Nazlıbilek, S. (2023) · International Conference on Systems and Control (ICSC) · doi:10.1109/icsc58660.2023.10449738 · Cited by 3
Altaf, A., Kumar, M., & Biswas, D. (2024) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet61574.2024.10717897 · Cited by 3
Load Frequency Control of Two Area Deregulated Power System Using Hybrid PSOGSA-TVAC Algorithm
Brahmachari, S., & Chanana, S. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-7664-2_29 · Cited by 3
Enhanced Control Designs to Abate Frequency Oscillations in Compensated Power System
Yousuf, S., Yousuf, V., Gupta, N., Alharbi, T., & Alrumayh, O. N. (2023) · Energies · doi:10.3390/en16052308 · Cited by 3
Hydraulic Power System Control using State Feedback Controller (SFC)
Fahmizal, F., Putra, J. T., Fatimawardhani, S., & Maghfiroh, H. (2023) · Journal of Fuzzy Systems and Control · doi:10.59247/jfsc.v1i1.30 · Cited by 3
Electric Vehicles in Smart Grids
Dărab, C. P. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch009 · Cited by 3
Power Quality Improvement in Distribution System Using Dynamic Voltage Restorer
Molla, T. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch003 · Cited by 3
“One of the solutions is to install a proper device at sensitive load location to mitigate the voltage sags and swells (Alhelou et al., 2019; Makdisie et al., 2018; Alhelou et al., 2018; Alhelou et al., 2016; Haes Alhelou et al., 2019; Njenda et al., 2018).”
BackgroundElectromechanical Mode Estimation in Power System Using a Novel Nonstationary Approach
Rahul, S. A., Koshy, S., & Sunitha, R. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_8 · Cited by 3
Mekki, N., & Krıchen, L. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_6 · Cited by 3
Aluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2021) · IEEE PES/IAS PowerAfrica Conference (PowerAfrica) · doi:10.1109/powerafrica52236.2021.9543142 · Cited by 3
“The third level is the tertiary frequency control used for economic dispatch and scheduling [8], [9].”
BackgroundHome Load-Side Management in Smart Grids Using Global Optimization
Recioui, A. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch005 · Cited by 3
Micky, R. R., Sunitha, R., & Ashok, S. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_19 · Cited by 3
Data-Driven Wide-Area Situation Analyzer for Power System Event Detection and Severity Assessment
Shrivastava, D. R., Siddiqui, S. A., & Verma, K. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_18 · Cited by 3
Ph.D Scholar, J., Kumar, K. V., Ganesh, V., & Professor, J. (2020) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.c5490.029320 · Cited by 3
Virtual Inertia Control Strategy for High Renewable Energy-Integrated Interconnected Power Systems
Aluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-1742-4_29 · Cited by 3
Optimal Selection of Phasor Measurement Units
Babu, N. V. P. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_5 · Cited by 3
Reinforcement Learning Data-Driven Optimal Load-Frequency Control for Power Systems
Zhao, Y. (2025) · EAI Endorsed Transactions on Energy Web · doi:10.4108/ew.7500 · Cited by 2
“…case of solving the optimal control issue of the dynamic system, the above method requires real-time observation of the dynamic state of the system, and the traditional dynamic programming method is often plagued by the ‘ dimension disaster ‘ problem, which makes its application limited[23][24].”
Luo, R., Shi, K., Zhang, X., & Ren, J. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.118615 · Cited by 2
Introduction to WAMS and Its Applications for Future Power System
Zamani, R., Panahi, H., Abyaz, A., & Alhelou, H. H. (2020) · Power systems · doi:10.1007/978-3-030-54275-7_2 · Cited by 2
Self-citationLoad-Frequency Control in a Two-Area Power System Using the Fuzzy-PID Method
Moghaddam, S. G., Bagheri, A. A., & Sedaghati, R. (2023) · ECTI Transactions on Electrical Engineering Electronics and Communications · doi:10.37936/ecti-eec.2023211.248665 · Cited by 2
Ali, A. M., Saad, M., Amari, A. E., & Hassan, M. (2023) · International Journal of Energy and Environmental Science · doi:10.11648/j.ijees.20230802.11 · Cited by 2
“…is implemented to it for these four loading situations in the existence of all system constraint uncertainties and the GRC. Alhelou et al. [9] provide a comprehensive survey on different challenges and viewpoints of AGC in both conventional and untraditional power stations and presents…”
BackgroundLoad Frequency Control of Single Area Using New Adaptive Controller
Elbassiouny, A. A., Attia, M. A., & Hamouda, R. M. (2024) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon63025.2024.10850262 · Cited by 2
Fuzzy PID with Filtered Derivative Mode Based Load Frequency Control of Two-Area Power System
Shouran, M., Anayi, F., & Packianather, M. (2021) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec50034.2021.9548233 · Cited by 2
EMC Installation for Variable Speed Drive Systems (VSDs)
Nadweh, S., Barakat, Z., & Hayek, G. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch013 · Cited by 2
Rao, G. S., Obulesh, Y. P., & Rao, B. V. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch002 · Cited by 2
Uninterrupted Power Supply to Micro-Grid During Islanding
Chandrakar, R., Nale, R., & Biswal, M. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch004 · Cited by 2
“Generally, batteries and generators are highly used in these uninterruptible power supply systems are batteries and/ or generators (Ahmad & Kashif, 2016; Alhelou et al, 2018; Njenda et al, 2018; Makdisie et al, 2018; Fini et al, 2016; Alhelou et al, 2016; Nadweh et al, 2018).”
BackgroundAlhalabi, M. T., Rashed, A., Barham, Y., Salim, R. I., & Ghazal, M. A. (2022) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet55527.2022.9873442 · Cited by 2
“Moreover, the increase in dependency on renewable energy generation [10] directed people to start designing LFCs for such systems.”
BackgroundLoad Frequency Control of Multi-Area Renewable Energy Micro-Grid System
Lalparmawii, R., Datta, S., Deb, S., & Singh, K. R. (2023) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet57834.2023.10245557 · Cited by 2
“Due to the irrigularties in supply of renewable source and fluctiation in load demand frequency and power deviation through tie line occurs [2] adding the complexity of power system [3].”
BackgroundOperation of Microgrid and Control Strategies
Veeraganti, S. D., & Nittala, R. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch019 · Cited by 2
“…way to realize the emerging potential of microgeneration is to take a system approach which views generation and associated loads as a subsystem or a Microgrid (Fini et al., 2016; Alhelou et al., 2018; Zamani et al., 2018; Alhelou et al., 2015; Njenda et al., 2018; Haes Alhelou et al., 2018).”
BackgroundTransition From Traditional Grid to Smart One
Daghrour, H., & Rhia, R. A. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch008 · Cited by 2
Guha, D., Roy, P. K., & Banerjee, S. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch003 · Cited by 2
Improvement of the Electrical Network Stability by Using a Renewable Distributed Generator
Krim, Y., Krim, S., & Mimouni, M. F. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch005 · Cited by 2
Voltage Drop Mitigation in Smart Distribution Network
Mebrahtu, F. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch004 · Cited by 2
“Even the voltage dip is 4 to 5 cycles, it affects the sensitive distribution materials to drop out fuses (Alhelou et al., 2019; Makdisie et al., 2018; Alhelou et al., 2018; Alhelou et al., 2016; Haes Alhelou et al., 2019; Njenda et al., 2018).”
BackgroundHarmonic Mitigation Techniques in Smart Distribution Network
Mebrahtu, F. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch006 · Cited by 2
A Dynamic Stability and Performance Analysis of Automatic Generation ControlPreprint
Simpson-Porco, J. W. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2007.01832 · Cited by 2
Ramshanker, A., Ravi, K., Raglend, I. J., & Edward, J. B. (2022) · Preprints.org · doi:10.20944/preprints202211.0422.v1 · Cited by 2
Introduction to Smart Grid and Micro-Grid Systems
Nadweh, S., & Barakat, Z. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch001 · Cited by 1
Sampled‐data‐based H ∞ load frequency control for power systems with wind power
Shi-gang, Q., Liu, D., & Lian, H. (2022) · IET Renewable Power Generation · doi:10.1049/rpg2.12578 · Cited by 1
Networked scheduling for decentralized load frequency control
Peng, C., & Yang, H. (2022) · Intelligence & Robotics · doi:10.20517/ir.2022.27 · Cited by 1
Horsfall, O. M., Nwazor, N. O., & Orakwue, S. I. (2023) · International Journal of Engineering Applied Sciences and Technology · doi:10.33564/ijeast.2023.v07i09.008 · Cited by 1
Structurally Constrained Fuzzy Selective LQ WADC Based on the Spectral Decomposition of Gramians
Kataev, D. E., & Kutyakov, E. Y. (2024) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2024.07.507 · Cited by 1
Sagor, A. R., Fahima, J. N., Sahed, S. H., Ahmad, S., Hazari, M. R., Parvez, M. S., Ahmed, K. F., & Hassan, M. (2025) · International Conference on Robotics, Electrical and Signal Processing Techniques (ICREST) · doi:10.1109/icrest63960.2025.10914392 · Cited by 1
“It outperforms MVO in [8] and resolves the slow convergence and sensitivity issues of GWO in [9] and [10].”
Resilient Robust Polynomial-Based Frequency Control in Microgrids with RESs Using Virtual Inertia
Golshaeian, S., Najafi, M., Gharehpetian, G. B., & Hosseinian, S. H. (2025) · Iranian Conference on Renewable Energy & Distributed Generation (ICREDG) · doi:10.1109/icredg66184.2025.10966109 · Cited by 1
“However, in microgrids with distributed generation, such as those using PV and wind systems, conventional methods may not be effective [11].”
Frequency and Active Power Control of Interconnected Microgrids: An ANN-Based PI Tuning Approach
Rabosha, M., Rehimi, S., & Bevrani, H. (2024) · Smart Grid Conference · doi:10.1109/sgc64640.2024.10983776 · Cited by 1
“However, fixed simple structure controllers may face difficulties when certain system parameter variations occur [7].”
A novel approach for frequency regulation of a hybrid power system
Nayak, S. R., Khadanga, R. K., & Panda, S. (2025) · Energy Systems · doi:10.1007/s12667-025-00754-3 · Cited by 1
Mohamed, M. T., Alkhalaf, S., Hemeida, A. M., & Abozaid, G. Y. (2025) · Journal of low frequency noise, vibration and active control · doi:10.1177/14613484251364210 · Cited by 1
“…versatile performance under various conditions is paramount in isolated μ Gs. Load Frequency Control (LFC) plays a crucial role in maintaining power balance within acceptable limits, 11 especially in off-grid μ Gs, where methods like energy sources, synthetic virtual inertia, and ESTs are employed.”
Chen, T., Liu, Y., Xu, Y., Ren, J., Jiang, Y., & Li, L. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.111382 · Cited by 1
Osaloni, O. O., & Dzobo, O. (2025) · WSEAS TRANSACTIONS ON POWER SYSTEMS · doi:10.37394/232016.2025.20.26 · Cited by 1
Hybrid hydrogen systems for mitigating sub synchronous oscillations in weak power grids
Alsenani, T. R., Shahzad, S., & Kılıç, H. (2026) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2026.153375 · Cited by 1
Khadanga, R. K., Panda, S., Das, D., Sahu, P. R., Mohanty, S., & Kumar, A. (2026) · International Journal of Ambient Energy · doi:10.1080/01430750.2025.2609595 · Cited by 1
Impact of Renewable Energy Penetration on Load Frequency Control
Mishra, P. K., Kumar, A., & Mishra, A. (2026) · International Conference on Electric Power and Renewable Energy (EPREC) · doi:10.1109/eprec66546.2026.11412278 · Cited by 1
“…frequency stability in such a changing environment requires redesigning or augmenting LFC systems with advanced control techniques, ultra-fast technologies like battery energy storage systems (BESS)[10], and smart forecasting systems that can predict and correct renewable variations in real time.”
Nguyen, N.-K., & Doan, D.-V. (2025) · Asia Meeting on Environment and Electrical Engineering (EEE-AM) · doi:10.1109/eee-am66675.2025.11473788 · Cited by 1
“This necessitates the precise regulation of critical operational parameters, such as frequency and voltage, within established tolerances [1].”
Zhang, S., Liu, Z., Zhang, H., & Wang, J. (2021) · Chinese Control Conference (CCC) · doi:10.23919/ccc52363.2021.9549664 · Cited by 1
Adaptive Neuro-Fuzzy Based Load Frequency Control in Presence of Energy Storage Devices
Jood, P., Aggarwal, S. K., & Chopra, V. (2022) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2022.025217 · Cited by 1
Discrete Control of Two-Area Power System Consisting Reheat Thermal and Renewable Sources
Jood, P., Aggarwal, S. K., & Chopra, V. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.04.044 · Cited by 1
Performance Assessment of Grey Wolf Technique for AGC of Multi-source Intertied System
Mohammed, A. N., & Chatterjee, S. (2022) · International Virtual Conference on Power Engineering Computing and Control: Developments in Electric Vehicles and Energy Sector for Sustainable Future (PECCON) · doi:10.1109/peccon55017.2022.9851118 · Cited by 1
Optimisation Techniques for Load Frequency Control
Soorefan, M. H. M., & Ramjug-Ballgobin, R. (2022) · International Conference on Emerging Trends in Electrical, Electronic and Communications Engineering (ELECOM) · doi:10.1109/elecom54934.2022.9965244 · Cited by 1
“LFC's primary goals are to sustain the frequency and intended output power of a power system and also to limit the variation of tie line power across control regions [4].”
BackgroundInvestigation of New Fuzzy Cascade Controller for Frequency Deviation in Hybrid Power Systems
Sinh, P., Patel, U. J., & Chothani, N. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-8353-5_7 · Cited by 1
Manual Frequency Restoration Reserve Markets: What Does the Data Tell Us?
Miletić, M., Capuder, T., Pandžić, H., & Pavić, I. (2023) · International Conference on the European Energy Market (EEM) · doi:10.1109/eem58374.2023.10161755 · Cited by 1
“The technical side of the coin was covered by authors in [7], who reviewed the state-of-the-art of secondary frequency control from the technical point of view.”
BackgroundKannepally, S., Kumar, D. V., & Vakula, V. S. (2023) · Electric Power Components and Systems · doi:10.1080/15325008.2023.2253804 · Cited by 1
“The LFC and AGC balance the load frequency in a multi-area connected power system and mitigates unscheduled power interchange between the generators [3].”
Shen, Z., Wang, C., Wang, Y., Zhao, H., Wu, Z., & Hu, E. (2023) · Frontiers in Energy Research · doi:10.3389/fenrg.2023.1290450 · Cited by 1
Hsia, Y. S., Haur, Y. K., Yip, S. Y., & Kwan, Z. H. (2024) · IEEE International Colloquium on Signal Processing & Its Applications (CSPA) · doi:10.1109/cspa60979.2024.10525601 · Cited by 1
Perturbation attenuation in Load Frequency Control
Dritsas, L. D., & Tzes, A. P. (2024) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med61351.2024.10566128 · Cited by 1
Qader, H. A., & Al-Bahrani, L. T. (2023) · International Symposium on Fundamentals of Electrical Engineering · doi:10.1109/isfee60884.2023.10637025 · Cited by 1
“The main challenge of producing a reliable electric energy for consumers is controlling the variation of load demand to keep the desired limits of frequency [3], [4].”
BackgroundStudy of Cyber Threats and its Challenges in LFC and its Mitigation via GDA based PID Controller
Johnbabu, B., Pattanayak, S., Kumar, V., & Hote, Y. V. (2024) · IEEE Conference on Control Technology and Applications (CCTA) · doi:10.1109/ccta60707.2024.10666508 · Cited by 1
“The various challenges faced by LFC due to cyber-attacks are listed below [15].”
BackgroundSoft-system management framework for power supply and grid integration issues
Gupta, L., & Shankar, R. (2024) · foresight · doi:10.1108/fs-11-2022-0145 · Cited by 1
Artificial Intelligence Techniques in Distribution Systems
Ranjbar, S., & Abedi, M. (2024) · Power systems · doi:10.1007/978-3-031-69358-8_11 · Cited by 2
Loss Minimization in Active Distribution Network
Simachew, B. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch007 · Cited by 1
Impacts of Distributed Generations on Power System
Kumar, K., & Kumar, M. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch010 · Cited by 1
Reliability Enhancement of Smart Distribution Network Using Reconfiguration
Anteneh, D. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch009 · Cited by 1
Energy Storage System and Its Power Electronic Interface
Khan, B., Degarege, S., Mebrahtu, F., & Alhelou, H. H. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch016 · Cited by 1
Self-citationMakdisie, C. J., & Mariam, M. F. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-1230-2.ch017 · Cited by 1
Visual Query Method for Large Blackouts Based on Knowledge Graph
Zhang, J., Bian, H., Rao, G., Han, X., Jin, X., & Zhang, L. (2019) · International Conference on Intelligent Computing, Automation and Systems (ICICAS) · doi:10.1109/icicas48597.2019.00053 · Cited by 1
“The power imbalance between demand and generation directly affects the frequency stability, while the voltage is directly affected by the reactive power imbalance [12].”
BackgroundTopler, M., Ritonja, J., & Polajžer, B. (2020) · IEEE Access · doi:10.1109/access.2020.3024830 · Cited by 1
“Furthermore, the proposed control strategies for LFC and AGC are studied and categorized into different control groups [22].”
MethodDesign of Networked Microgrid‟s Control towards Power Coordination and Voltage Frequency Regulation
Amin, N., & Hasan, K. N. (2020) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.d8908.049420 · Cited by 1
Operation of Microgrid and Control Strategies
Veeraganti, S. D., & Nittala, R. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch006 · Cited by 1
Issues Associated With Microgrid Integration
Khan, B., & Tanwar, S. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch062 · Cited by 1
Electric Vehicles in Smart Grids
Dărab, C. P. (2021) · IGI Global eBooks · doi:10.4018/978-1-6684-3666-0.ch054 · Cited by 1
Zapanta, E. T., & Santiago, R. V. M. (2022) · International Conference on Computational Intelligence and Communication Networks (CICN) · doi:10.1109/cicn56167.2022.10008353 · Cited by 1
“Furthermore, control loop performance testing of their proposed control strategy/framework was restricted to small random disturbance responses only using the transfer function model of an interconnected power system[18], which only takes time constants and power system inertia into account.”
MethodVeerendar, T., Kumar, D., & Sreeram, V. (2023) · Asian Journal of Control · doi:10.1002/asjc.3096 · Cited by 1
Faal, S. F., Sahab, A., & Alizadeh, B. (2023) · Journal of New Materials for Electrochemical Systems · doi:10.14447/jnmes.v26i1.a09 · Cited by 1
Riaz, M. U., & Malik, S. A. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6346302 · Cited by 1
Power Quality and Stability Analysis of Variable-Speed Drive Systems (VSDS)
Nadweh, S., & Khaddam, O. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch017
Management of Electrical Maintenance of University Buildings Using Deterioration Models
Alhassan, B. M., Omran, J. Y., & Jrad, F. A. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch016
Operation and Control of Microgrid
Maheswari, M., & Gunasekharan, S. (2019) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-8030-0.ch018
Alhelou, H. H., Golshan, M. E. H., & Siano, P. (2019) · International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest.2019.8849035
“The applicability of these methods faced several technical issues which can be found in [18-20].”
BackgroundSelf-citationSalim, N. A., Samah, M. S. A., Mohamad, H., Yasin, Z. M., & Aziz, N. F. A. (2020) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v17.i2.pp606-614
Metadata
- Authors
- Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P.
- Affiliations
- Latakia University (SY)
- Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- Isfahan University of Technology (IR)
- Esfahan Electricity Power Distribution Company (EEPDC), Isfahan 81737-51387, Iran
- University of Salerno (IT)
- Corresponding author
- Siano, Pierluigi
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2018-09-20
- Volume
- 11
- Issue
- 10
- Pages
- 2497
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2890216498
- Cited by
- 349
- References
- 315
- Citations by year
- 2026: 15 · 2025: 33 · 2024: 35 · 2023: 47 · 2022: 41 · 2021: 69 · 2020: 41 · 2019: 62 · 2018: 6
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Keywords
- load frequency control, secondary frequency control, primary frequency control, power system frequency stability, smart power systems, control strategy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.