Analysis of the Impact of Stator Inter-Turn Short Circuits on PMSM Drive with Scalar and Vector Control
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Permanent Magnet Synchronous Motor (PMSM) failures are currently widely discussed in the literature, but the impact of these failures on the operation of control systems and the ability to detect selected failures despite the compensating effect of control algorithms being relatively rarely analyzed. The article presents the impact of damage to the stator winding of a PMSM motor on the operation of two frequency control structures, scalar and vector control. The mathematical model of PMSM that takes into account the influence of a different number of shorted turns in the stator winding phase was presented, and its experimental verification was performed. Then, the influence of various degrees of damage to the stator winding on the waveforms of the motor state variables in an open scalar control structure and in a closed field-oriented control structure was analyzed. Based on the analysis of phase currents and rotational speed of the motor as well as the influence of the PMSM motor operating conditions, the basic techniques of extracting the symptoms of stator winding inter-turn short-circuits were analyzed, and the failure indicators were developed, which enable simple diagnostics of the stator winding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [42]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
Sensorless Vector and Direct Torque Control
Vas, P. (1998) · doi:10.1093/oso/9780198564652.001.0001 · Cited by 2,571
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A new convolutional neural network-based data-driven fault diagnosis method
Wen, L., Li, X., Gao, L., & Zhang, Y. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2774777 · Cited by 2,222
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
A sensorless, stable v/f control method for permanent-magnet synchronous motor drives
Perera, P. D. C., Blaabjerg, F., Pedersen, J. K., & Thogersen, P. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.810624 · Cited by 240
Analysis of Permanent Magnet Synchronous Motor Fault Diagnosis Based on Learning
Kao, I.-H., Wang, W.-J., Lai, Y.-H., & Perng, J.-W. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2847800 · Cited by 221
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
BackgroundMethodResultSelf-citationMohammad‐Alikhani, A., Nahid‐Mobarakeh, B., & Hsieh, M. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3265054 · Cited by 131
Sergakis, A., Salinas, M., Gkiolekas, N., & Gyftakis, K. N. (2025) · Energies · doi:10.3390/en18051177 · Cited by 58
Machine Learning-Based Stator Current Data-Driven PMSM Stator Winding Fault Diagnosis
Pietrzak, P., & Wolkiewicz, M. (2022) · Sensors · doi:10.3390/s22249668 · Cited by 44
“Moreover, stator winding faults are also well reflected in voltage [19] and axial flux [20] signals as well as the internal signals of the control structure of the PMSM drive system [21].”
BackgroundPietrzak, P., & Wolkiewicz, M. (2023) · Electronics · doi:10.3390/electronics12071543 · Cited by 33
Romdhane, M., Mohamed, N., & Mansouri, A. (2023) · Electronics · doi:10.3390/electronics12183758 · Cited by 28
Recent Advances in Fault Detection and Analysis of Synchronous Motors: A Review
Gherghina, I.-S., Bizon, N., Iana, G. V., & Vasilică, B.-V. (2025) · Machines · doi:10.3390/machines13090815 · Cited by 37
A Current Sensor Fault Tolerant Control Strategy for PMSM Drive Systems Based on Cri Markers
Jankowska, K. A., & Dybkowski, M. (2021) · Energies · doi:10.3390/en14123443 · Cited by 21
“Mathematical Model of the Vector Controlled PMSM Drive System Describing the model of a PMSM several simplifications should be taken into account, such as: three phase symmetrical stator winding, magnetic circuits are linear, isotropic (saturation, eddy currents, and hysteresis are ignored), constant resistance and in…”
MethodPietrzak, P., & Wolkiewicz, M. (2021) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc48073.2021.9432629 · Cited by 26
Skowron, M., Krzysztofiak, M., & Orłowska-Kowalska, T. (2022) · IEEE Access · doi:10.1109/access.2022.3211087 · Cited by 20
“amplitude of the 3fs harmonics, as presented in [8].”
BackgroundSelf-citationNavarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Mohamed, N., Flah, A., Mouna, B. H., & Sbita, L. (2021) · International Symposium on Advanced Electrical and Communication Technologies (ISAECT) · doi:10.1109/isaect53699.2021.9668411 · Cited by 14
Overview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Pietrzak, P., & Wolkiewicz, M. (2024) · Power Electronics and Drives · doi:10.2478/pead-2024-0007 · Cited by 10
“The most popular methods of processing this signal to extract the fault symptoms of the PMSM stator windings are frequency-domain analysis methods, such as motor current signature analysis (MCSA) which is based on the application of fast Fourier transform (FFT) (Krzysztofiak et al., 2020; Haddad and Strangas, 2016).”
MethodDiagnostics of Interturn Short Circuits in PMSMs With Online Fault Indicators Estimation
Zezula, L., Kozovský, M., & Bláha, P. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3363775 · Cited by 17
“…a low short-circuit impedance and an increased voltage amplified by coupled flux linkages, a significant fault current flows through the interturn short circuit (ISC), raising the current in the entire stator phase, generating heat, and further contributing to insulation material degradation [1], [2].”
BackgroundInterturn Short-Circuit Fault Diagnosis and Localization of PMSM Based on Current Trajectory
Yu, Y., Yang, S., Zhang, X., Qu, Y., & Qin, G. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3495826 · Cited by 13
“The signal processing method avoids the modeling problem to some extent, and the fault feature signal is extracted by a variety of signal processing techniques [10], [11], [12], [13].”
Suti, A., Rito, G. D., & Galatolo, R. (2022) · Aerospace · doi:10.3390/aerospace9070337 · Cited by 13
Харитонов, Я. С., Vasilyev, P., Bebikhov, Y. V., Egorov, A. N., & Semenov, A. S. (2022) · Transportation research procedia · doi:10.1016/j.trpro.2022.06.308 · Cited by 10
Suti, A., Rito, G. D., & Galatolo, R. (2022) · Aerospace · doi:10.3390/aerospace9080401 · Cited by 10
“Acronym Method Reference M1 FFT [13] M2 HHT transforms [38] M3 PVA [31] M4 CNN [39] M5 APVA Present work Table 3.”
BackgroundInfluentialOuamara, D., Boukhnifer, M., Chaibet, A., & Maidi, A. (2023) · Diagnostyka · doi:10.29354/diag/161309 · Cited by 6
Efficiency of Intelligent Control Design for Dual-Stator Machine on the EV Traction System
Mohamed, N., Flah, A., & Sbita, L. (2023) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-023-08070-7 · Cited by 5
“But on the other side, this advantage was joined by a drawback related to the control strategy, which is complicated and has more than parameters that can affect its performance [9, 10].”
BackgroundStator Phase Current STFT analysis for the PMSM Stator Winding Fault Diagnosis
Pietrzak, P., & Wolkiewicz, M. (2022) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam53979.2022.9841990 · Cited by 6
Emulation of a Permanent Magnet Synchronous Machine with Stator Winding Fault
Kalarikkal, N., Boby, M., & Pillay, P. (2023) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds57185.2023.10246704 · Cited by 5
Vibrating Feeder Electromagnetic Drive Model Implemented in MatLab/Simulink
Semenov, A. S., Semenova, M. N., Bebikhov, Y. V., Egorov, A. N., Vasilyev, P., & Харитонов, Я. С. (2021) · International Conference on Electrotechnical Complexes and Systems (ICOECS) · doi:10.1109/icoecs52783.2021.9657343 · Cited by 5
Pietrzak, P., & Wolkiewicz, M. (2022) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.24425/bpasts.2022.140556 · Cited by 5
“Despite their high reliability, PMSMs like other types of electric motor types used in drive systems, are prone to various types of faults during normal operation [4].”
BackgroundPietrzak, P., Wolkiewicz, M., & Kotarski, J. (2024) · Electronics · doi:10.3390/electronics13152975 · Cited by 3
Optimized FOC control strategy for dual stators permanent magnet machine
Elnaggar, M. F., Flah, A., El‐Bayeh, C. Z., & Alrashed, M. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-11435-7 · Cited by 2
Application of PMSM fault detector based on Kohonen classifier and FEM model
Skowron, M., Krzysztofiak, M., & Orłowska-Kowalska, T. (2022) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam53979.2022.9842181 · Cited by 2
Self-citationSergakis, A., Gkiolekas, N., Salinas, M., Mueller, M., & Gyftakis, K. N. (2025) · Energies · doi:10.3390/en18225973 · Cited by 1
A control strategy of a permanent magnet synchronous motor for an electric vehicle
Xie, J., & Liu, Z. (2022) · Journal of Theoretical and Applied Mechanics/Mechanika Teoretyczna i Stosowana · doi:10.15632/jtam-pl/156181
Based on Chaos Neural Network Vector Control for Permanent Magnet Synchronous Motors
Zhang, J., Chen, M., & Wei, Y. (2024) · International Conference on Signal Processing and Intelligent Computing (SPIC) · doi:10.1109/spic62469.2024.10691563
Yang, A., & Li, Y. (2025) · International Journal of Dynamics and Control · doi:10.1007/s40435-025-01684-9
“It requires minimal hardware, and hence, is a low-cost solution [3].”
Diagnosis Method of PMSM Inter-turn Short Circuit Based on Dual Feature Fusion
Chen, Q. (2026) · International Conference on Mechanical, Electronics and Electrical and Automation Control (METMS) · doi:10.1109/metms70800.2026.11705844
“In addition, PMSMs are typically controlled using vector control strategies, where closed-loop controllers automatically compensate for torque ripples caused by faults, thereby reducing the sensitivity of residual-based diagnostic methods [2] .”
Metadata
- Authors
- Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T.
- Affiliations
- Wrocław University of Science and Technology (PL)
- Department of Electrical Machines, Drives and Measurements, Wroclaw University of Science and Technology, wyb. Wyspianskiego 27, 50-370 Wroclaw, Poland
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2020-12-30
- Volume
- 14
- Issue
- 1
- Pages
- 153
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3117449092
- Cited by
- 33
- References
- 26
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 7 · 2022: 10 · 2021: 4
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowym Centrum Nauki (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- permanent magnet synchronous motor, stator inter-turn short circuit, scalar control, vector control, field-oriented control, fault diagnosis, failure indicators, phase current waveform, rotational speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.