Analysis of the Impact of Stator Inter-Turn Short Circuits on PMSM Drive with Scalar and Vector Control

Open access
Krzysztofiak, Mateusz, Skowron, Maciej, Orlowska-Kowalska, Teresa · 2020 · Energies

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Permanent Magnet Synchronous Motor (PMSM) failures are currently widely discussed in the literature, but the impact of these failures on the operation of control systems and the ability to detect selected failures despite the compensating effect of control algorithms being relatively rarely analyzed. The article presents the impact of damage to the stator winding of a PMSM motor on the operation of two frequency control structures, scalar and vector control. The mathematical model of PMSM that takes into account the influence of a different number of shorted turns in the stator winding phase was presented, and its experimental verification was performed. Then, the influence of various degrees of damage to the stator winding on the waveforms of the motor state variables in an open scalar control structure and in a closed field-oriented control structure was analyzed. Based on the analysis of phase currents and rotational speed of the motor as well as the influence of the PMSM motor operating conditions, the basic techniques of extracting the symptoms of stator winding inter-turn short-circuits were analyzed, and the failure indicators were developed, which enable simple diagnostics of the stator winding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en14010153

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Equivalent circuit of the PMSM stator winding with shorted turns in phase Figure 1. Equivalent circuit of the PMSM stator winding with shorted turns in phase A .
Figure 1 Equivalent circuit of the PMSM stator winding with shorted turns in phase Figure 1. Equivalent circuit of the PMSM stator winding with shorted turns in phase A .CC-BY · From the PDF
Figure 2 Experimental verification of the proposed mathematical model of PMSM with short circuits in the stator winding: ( a ) instantaneous occurring of the shorted turns; ( b ) instantaneous occurring of the shorted turns-zoom; TL = Figure 2. Experimental verification of the proposed mathematical model of PMSM with short circuits in the stator winding: ( a ) instantaneous occurring of the shorted turns; ( b ) instantaneous occurring of the shorted turns-zoom; TL = TN , f s = 100 Hz.
Figure 2 Experimental verification of the proposed mathematical model of PMSM with short circuits in the stator winding: ( a ) instantaneous occurring of the shorted turns; ( b ) instantaneous occurring of the shorted turns-zoom; TL = Figure 2. Experimental verification of the proposed mathematical model of PMSM with short circuits in the stator winding: ( a ) instantaneous occurring of the shorted turns; ( b ) instantaneous occurring of the shorted turns-zoom; TL = TN , f s = 100 Hz.CC-BY · From the PDF
Figure 3 The spectral analysis of the PMSM stator current in phase B : ( a ) simulation results; ( b ) experimental results; TL = TN , f s = 100 Hz. Figure 3. The spectral analysis of the PMSM stator current in phase B : ( a ) simulation results; ( b ) experimental results; TL = TN , f s = 100 Hz.
Figure 3 The spectral analysis of the PMSM stator current in phase B : ( a ) simulation results; ( b ) experimental results; TL = TN , f s = 100 Hz. Figure 3. The spectral analysis of the PMSM stator current in phase B : ( a ) simulation results; ( b ) experimental results; TL = TN , f s = 100 Hz.CC-BY · From the PDF
Image 4
CC-BY · From the PDF
Figure 5 Stator voltage calculation with Rs -voltage drop and load torque compensation. Figure 5. Stator voltage calculation with Rs -voltage drop and load torque compensation.
Figure 5 Stator voltage calculation with Rs -voltage drop and load torque compensation. Figure 5. Stator voltage calculation with Rs -voltage drop and load torque compensation.CC-BY · From the PDF
Figure 6 Scheme of the field-oriented control of the PMSM drive. Figure 6. Scheme of the field-oriented control of the PMSM drive.
Figure 6 Scheme of the field-oriented control of the PMSM drive. Figure 6. Scheme of the field-oriented control of the PMSM drive.CC-BY · From the PDF
Figure 7 Waveforms of undamaged motor state variables for different values of the load torque, TL = (0-1) TN and for f s = 100 Hz in the scalar control structure (open system with load torque compensation): ( a , c , e ) and in the field-oriented control structure: ( b , d , f ). Transients of the rotor speed ( a , b ), phase current ( c , d ), electromagnetic, and load torques ( e , f ). Figure 7. Waveforms of undamaged motor state variables for different values of the load torque, TL = (0-1) TN and for f s = 100 Hz in the scalar control structure (open system with load torque compensation): ( a , c , e ) and in the field-oriented control structure: ( b , d , f ). Transients of the rotor speed ( a , b ), phase current ( c , d ), electromagnetic, and load torques ( e , f ).
Figure 7 Waveforms of undamaged motor state variables for different values of the load torque, TL = (0-1) TN and for f s = 100 Hz in the scalar control structure (open system with load torque compensation): ( a , c , e ) and in the field-oriented control structure: ( b , d , f ). Transients of the rotor speed ( a , b ), phase current ( c , d ), electromagnetic, and load torques ( e , f ). Figure 7. Waveforms of undamaged motor state variables for different values of the load torque, TL = (0-1) TN and for f s = 100 Hz in the scalar control structure (open system with load torque compensation): ( a , c , e ) and in the field-oriented control structure: ( b , d , f ). Transients of the rotor speed ( a , b ), phase current ( c , d ), electromagnetic, and load torques ( e , f ).CC-BY · From the PDF
Figure 8 Phase current waveforms at the moment of short-circuit Nsf =5 turns in the PMSM motor for f s = 100 Hz, TL = 0.2 TN : scalar control (open system with load torque compensation) ( a ), field-oriented control ( b ). Figure 8. Phase current waveforms at the moment of short-circuit Nsf =5 turns in the PMSM motor for f s = 100 Hz, TL = 0.2 TN : scalar control (open system with load torque compensation) ( a ), field-oriented control ( b ).
Figure 8 Phase current waveforms at the moment of short-circuit Nsf =5 turns in the PMSM motor for f s = 100 Hz, TL = 0.2 TN : scalar control (open system with load torque compensation) ( a ), field-oriented control ( b ). Figure 8. Phase current waveforms at the moment of short-circuit Nsf =5 turns in the PMSM motor for f s = 100 Hz, TL = 0.2 TN : scalar control (open system with load torque compensation) ( a ), field-oriented control ( b ).CC-BY · From the PDF
Figure 9 The current space vector hodograph for an undamaged and a damaged motor: scalar control ( a ), field-oriented control ( b ); 5 and 8 shorted turns in stator winding; f s = 100 Hz. Figure 9. The current space vector hodograph for an undamaged and a damaged motor: scalar control ( a ), field-oriented control ( b ); 5 and 8 shorted turns in stator winding; f s = 100 Hz.
Figure 9 The current space vector hodograph for an undamaged and a damaged motor: scalar control ( a ), field-oriented control ( b ); 5 and 8 shorted turns in stator winding; f s = 100 Hz. Figure 9. The current space vector hodograph for an undamaged and a damaged motor: scalar control ( a ), field-oriented control ( b ); 5 and 8 shorted turns in stator winding; f s = 100 Hz.CC-BY · From the PDF
Image 10
CC-BY · From the PDF
Image 11
CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Figure 13 Dependence of the 2nd harmonic of the rotor speed, 2 f s , on the number of shorted turns and the load torque values for f s = 100 Hz: scalar control ( a ), field-oriented control ( b ). Figure 13. Dependence of the 2nd harmonic of the rotor speed, 2 f s , on the number of shorted turns and the load torque values for f s = 100 Hz: scalar control ( a ), field-oriented control ( b ).
Figure 13 Dependence of the 2nd harmonic of the rotor speed, 2 f s , on the number of shorted turns and the load torque values for f s = 100 Hz: scalar control ( a ), field-oriented control ( b ). Figure 13. Dependence of the 2nd harmonic of the rotor speed, 2 f s , on the number of shorted turns and the load torque values for f s = 100 Hz: scalar control ( a ), field-oriented control ( b ).CC-BY · From the PDF
Figure 14 Waveforms of the failure index f i for the operating frequency f s =100 Hz: scalar control ( a , c , e ); field-oriented control ( b , d , f ); for different load torque values: TL ≈ 0 ( a , b ); TL = 0.6 TN ( c , d ); TL = TN ( e , f ). Figure 14. Waveforms of the failure index f i for the operating frequency f s =100 Hz: scalar control ( a , c , e ); field-oriented control ( b , d , f ); for different load torque values: TL ≈ 0 ( a , b ); TL = 0.6 TN ( c , d ); TL = TN ( e , f ).
Figure 14 Waveforms of the failure index f i for the operating frequency f s =100 Hz: scalar control ( a , c , e ); field-oriented control ( b , d , f ); for different load torque values: TL ≈ 0 ( a , b ); TL = 0.6 TN ( c , d ); TL = TN ( e , f ). Figure 14. Waveforms of the failure index f i for the operating frequency f s =100 Hz: scalar control ( a , c , e ); field-oriented control ( b , d , f ); for different load torque values: TL ≈ 0 ( a , b ); TL = 0.6 TN ( c , d ); TL = TN ( e , f ).CC-BY · From the PDF
Figure 15 Dependence of the failure index, f i , on the number of shorted turns and the VSI frequency for TL ≈ 0: scalar control ( a ), field-oriented control ( b ). Figure 15. Dependence of the failure index, f i , on the number of shorted turns and the VSI frequency for TL ≈ 0: scalar control ( a ), field-oriented control ( b ). Energies 2021 , 14 , x FOR PEER REVIEW 19 of 22
Figure 15 Dependence of the failure index, f i , on the number of shorted turns and the VSI frequency for TL ≈ 0: scalar control ( a ), field-oriented control ( b ). Figure 15. Dependence of the failure index, f i , on the number of shorted turns and the VSI frequency for TL ≈ 0: scalar control ( a ), field-oriented control ( b ). Energies 2021 , 14 , x FOR PEER REVIEW 19 of 22CC-BY · From the PDF
Figure 16 Dependence of the failure index in the field-oriented control, on the number of shorted turns and the voltage frequency for: TL = 0.6 TN ( a ), TL = TN ( b ). Figure 16. Dependence of the failure index in the field-oriented control, on the number of shorted turns and the voltage frequency for: TL = 0.6 TN ( a ), TL = TN ( b ). { } min , , AB BC CA CA p f f f f f Phase B == =   The minimum value found will correspond to an undamaged motor phase. Exam-
Figure 16 Dependence of the failure index in the field-oriented control, on the number of shorted turns and the voltage frequency for: TL = 0.6 TN ( a ), TL = TN ( b ). Figure 16. Dependence of the failure index in the field-oriented control, on the number of shorted turns and the voltage frequency for: TL = 0.6 TN ( a ), TL = TN ( b ). { } min , , AB BC CA CA p f f f f f Phase B == =   The minimum value found will correspond to an undamaged motor phase. Exam-CC-BY · From the PDF
Figure 17 Waveforms of the failure index f p for the operating frequency f s = 100 Hz, TL ≈ 0: scalar control ( a ); field-oriented control ( b ); an example of the inter-turn short-circuit in the phase A , Nsf = 1. Figure 17. Waveforms of the failure index fp for the operating frequency f s = 100 Hz, TL ≈ 0: scalar control ( a ); field-oriented control ( b ); an example of the inter-turn short-circuit in the phase A , Nsf = 1.
Figure 17 Waveforms of the failure index f p for the operating frequency f s = 100 Hz, TL ≈ 0: scalar control ( a ); field-oriented control ( b ); an example of the inter-turn short-circuit in the phase A , Nsf = 1. Figure 17. Waveforms of the failure index fp for the operating frequency f s = 100 Hz, TL ≈ 0: scalar control ( a ); field-oriented control ( b ); an example of the inter-turn short-circuit in the phase A , Nsf = 1.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Research works printed but not linked: 1

  1. Commission Regulation (EU) 2019/1781 of 1 October 2019 laying down ecodesign requirements for electric motors and variable speed drives pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and repealing Commission Regulation (EC) No 640/2009. Off. J. Eur. Union 2019, 62, 74-94.

Cited by

See all 33

Metadata

Authors
Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T.
Affiliations
  • Wrocław University of Science and Technology (PL)
  • Department of Electrical Machines, Drives and Measurements, Wroclaw University of Science and Technology, wyb. Wyspianskiego 27, 50-370 Wroclaw, Poland
Venue
Energies
Publisher
MDPI AG
Published
2020-12-30
Volume
14
Issue
1
Pages
153
ISSN
1996-1073 (ISSN-L)
OpenAlex
W3117449092
Cited by
33
References
26
Citations by year
2026: 1 · 2025: 5 · 2024: 6 · 2023: 7 · 2022: 10 · 2021: 4
FWCI
1.80
Type
journal article
Language
en
Open access
Locations
  • Energies (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Narodowym Centrum Nauki (2017/27/B/ST7/00816)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
Keywords
permanent magnet synchronous motor, stator inter-turn short circuit, scalar control, vector control, field-oriented control, fault diagnosis, failure indicators, phase current waveform, rotational speed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.