Analysis of the Impact of Stator Inter-Turn Short Circuits on PMSM Drive with Scalar and Vector Control
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Permanent Magnet Synchronous Motor (PMSM) failures are currently widely discussed in the literature, but the impact of these failures on the operation of control systems and the ability to detect selected failures despite the compensating effect of control algorithms being relatively rarely analyzed. The article presents the impact of damage to the stator winding of a PMSM motor on the operation of two frequency control structures, scalar and vector control. The mathematical model of PMSM that takes into account the influence of a different number of shorted turns in the stator winding phase was presented, and its experimental verification was performed. Then, the influence of various degrees of damage to the stator winding on the waveforms of the motor state variables in an open scalar control structure and in a closed field-oriented control structure was analyzed. Based on the analysis of phase currents and rotational speed of the motor as well as the influence of the PMSM motor operating conditions, the basic techniques of extracting the symptoms of stator winding inter-turn short-circuits were analyzed, and the failure indicators were developed, which enable simple diagnostics of the stator winding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [42]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
Sensorless Vector and Direct Torque Control
Vas, P. (1998) · doi:10.1093/oso/9780198564652.001.0001 · Cited by 2,571
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A new convolutional neural network-based data-driven fault diagnosis method
Wen, L., Li, X., Gao, L., & Zhang, Y. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2774777 · Cited by 2,222
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
A sensorless, stable v/f control method for permanent-magnet synchronous motor drives
Perera, P. D. C., Blaabjerg, F., Pedersen, J. K., & Thogersen, P. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.810624 · Cited by 240
Analysis of Permanent Magnet Synchronous Motor Fault Diagnosis Based on Learning
Kao, I.-H., Wang, W.-J., Lai, Y.-H., & Perng, J.-W. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2847800 · Cited by 221
Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218 · cited 2×
“In [24], the method based on the zerosequence components was proposed.”
MethodRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Ebrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Haddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158 · cited 1×
“The most popular method used for the diagnosis of inter-turn short-circuits is the spectral analysis of the stator current [19,20] in which the components of the stator current spectrum obtained from the short-circuit PMSM model are analyzed for the extraction of short-circuit symptoms.”
MethodSkowron, M., Orłowska-Kowalska, T., Wolkiewicz, M., & Kowalski, C. T. (2020) · Energies · doi:10.3390/en13061475 · Cited by 125
Self-citationOnline Stator Interturn Short Circuits Monitoring in the DFOC Induction-Motor Drive
Wolkiewicz, M., Tarchala, G., Orlowska-Kowalska, T., & Kowalski, C. T. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2520902 · Cited by 104
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90 · cited 3×
“Moreover, the signals coming from the PMSM control-loop were used in the detection of inter-turn short circuits [21].”
BackgroundMethodDetection of Interturn Short-Circuit Fault for PMSM With Simple Fault Indicator
Hang, J., Ding, S., Zhang, J., Cheng, M., Chen, W., & Wang, Q. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2583780 · Cited by 87 · cited 2×
“In the article [23], the authors propose a simple fault indicator defined as a sum of the absolute values of the differences between the amplitudes the successive fundamental components of the stator currents.”
BackgroundMethodSkowron, M., Wolkiewicz, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2019) · Applied Sciences · doi:10.3390/app9040616 · Cited by 64
Self-citationFault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64 · cited 1×
“In [22], the authors present the impact of a coil short-circuit on the field-oriented control (FOC) structure, also presenting the possibility of torque ripple compensation.”
BackgroundReview of fault modeling methods for permanent magnet synchronous motors and their comparison
Usman, A., Joshi, B. M., & Rajpurohit, B. S. (2017) · 2017 IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062347 · Cited by 57
Liu, W., Chen, S., & Huang, H. (2019) · IEEE Access · doi:10.1109/access.2019.2948945 · Cited by 52 · cited 1×
“Permanent magnet synchronous motors (PMSM), which offer high efficiency, wide range of rotational speed control, high torque overload, low rotor inertia, as well as simple structure, fit well with the above-mentioned requirements [2].”
BackgroundState of the Art on Stray Flux Analysis in Faulted Electrical Machines
Capolino, G.-A., Romary, R., Henao, H., & Pusca, R. (2019) · 2019 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD) · doi:10.1109/wemdcd.2019.8887805 · Cited by 49
Maraaba, L. S., Al‐Hamouz, Z., & Abido, M. A. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2886137 · Cited by 40 · cited 1×
“Inter-turn short-circuits cause the flow of currents reaching amplitudes with values several times greater than the rated one [4,5].”
BackgroundDiagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine
He, J., Somogyi, C., Strandt, A., & Demerdash, N. A. O. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953825 · Cited by 39 · cited 1×
“Inter-turn short-circuits of the stator winding belonging to electrical defects are the second most common type of damage to electric motors, accounting for about 36% of all failures [3].”
Background
Research works printed but not linked: 1
- Commission Regulation (EU) 2019/1781 of 1 October 2019 laying down ecodesign requirements for electric motors and variable speed drives pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and repealing Commission Regulation (EC) No 640/2009. Off. J. Eur. Union 2019, 62, 74-94.
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
BackgroundMethodResultSelf-citationMohammad‐Alikhani, A., Nahid‐Mobarakeh, B., & Hsieh, M. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3265054 · Cited by 131
Sergakis, A., Salinas, M., Gkiolekas, N., & Gyftakis, K. N. (2025) · Energies · doi:10.3390/en18051177 · Cited by 62
Machine Learning-Based Stator Current Data-Driven PMSM Stator Winding Fault Diagnosis
Pietrzak, P., & Wolkiewicz, M. (2022) · Sensors · doi:10.3390/s22249668 · Cited by 44
“Moreover, stator winding faults are also well reflected in voltage [19] and axial flux [20] signals as well as the internal signals of the control structure of the PMSM drive system [21].”
BackgroundPietrzak, P., & Wolkiewicz, M. (2023) · Electronics · doi:10.3390/electronics12071543 · Cited by 33
Metadata
- Authors
- Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T.
- Affiliations
- Wrocław University of Science and Technology (PL)
- Department of Electrical Machines, Drives and Measurements, Wroclaw University of Science and Technology, wyb. Wyspianskiego 27, 50-370 Wroclaw, Poland
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2020-12-30
- Volume
- 14
- Issue
- 1
- Pages
- 153
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3117449092
- Cited by
- 33
- References
- 26
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 7 · 2022: 10 · 2021: 4
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowym Centrum Nauki (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- permanent magnet synchronous motor, stator inter-turn short circuit, scalar control, vector control, field-oriented control, fault diagnosis, failure indicators, phase current waveform, rotational speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.