The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
Open accessAbstract
The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones. Commercially available sensors for detection of VOCs and their metrological parameters—measurement range, limit of detection, measurement resolution, sensitivity and response time—were presented. Moreover, development trends and prospects of improvement of the metrological parameters of these sensors were highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human health effects of air pollution
Kampa, M., & Castanas, E. (2008) · Environmental Pollution · doi:10.1016/j.envpol.2007.06.012 · Cited by 4,496
Gas Sensors Based on Conducting Polymers
Bai, H., & Shi, G. (2007) · Sensors · doi:10.3390/s7030267 · Cited by 1,577
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Oxide Semiconductor Gas Sensors
Yamazoe, N., Sakai, G., & Shimanoe, K. (2003) · Catalysis Surveys from Asia · doi:10.1023/a:1023436725457 · Cited by 1,291
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
A review of gas sensors employed in electronic nose applications
Arshak, K., Moore, E., Lyons, G. M., Harris, J., & Clifford, S. (2004) · Sensor Review · doi:10.1108/02602280410525977 · Cited by 802
Changes in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
The effects of thickness and operation temperature on ZnO:Al thin film CO gas sensor
Chang, J. F., Kuo, H.-Y., Leu, I., & Hon, M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00034-5 · Cited by 544
Handbook of Machine Olfaction: Electronic Nose Technology
(2002) · Wiley eBooks · doi:10.1002/3527601597 · Cited by 498
Cited by
Advanced Micro- and Nano-Gas Sensor Technology: A Review
Nazemi, H., Joseph, A., Park, J., & Emadi, A. (2019) · Sensors · doi:10.3390/s19061285 · Cited by 614
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Spinelle, L., Gerboles, M., Kok, G., Persijn, S., & Sauerwald, T. (2017) · Sensors · doi:10.3390/s17071520 · Cited by 439
Parmentola, A., Petrillo, A., Tutore, I., & De Felice, F. (2022) · Business Strategy and the Environment · doi:10.1002/bse.2882 · Cited by 429
Liu, L., Guo, X., & Lee, C. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106304 · Cited by 402
Metadata
- Authors
- Szulczyński, B., & Gębicki, J.
- Venue
- Environments
- Publisher
- MDPI AG
- Published
- 2017-03-06
- Volume
- 4
- Issue
- 1
- Pages
- 21
- ISSN
- 2076-3298 (ISSN-L)
- OpenAlex
- W2592748762
- Cited by
- 282
- References
- 40
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air. https://app.cochat.ai/papers/10.3390/environments4010021
- The paper
- Szulczyński, B., & Gębicki, J. (2017). Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air. Environments. https://doi.org/10.3390/environments4010021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.