Contrast Agents for Photoacoustic and Thermoacoustic Imaging: A Review
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Photoacoustic imaging (PAI) and thermoacoustic imaging (TAI) are two emerging biomedical imaging techniques that both utilize ultrasonic signals as an information carrier. Unique advantages of PAI and TAI are their abilities to provide high resolution functional information such as hemoglobin and blood oxygenation and tissue dielectric properties relevant to physiology and pathology. These two methods, however, may have a limited detection depth and lack of endogenous contrast. An exogenous contrast agent is often needed to effectively resolve these problems. Such agents are able to greatly enhance the imaging contrast and potentially break through the imaging depth limit. Furthermore, a receptor-targeted contrast agent could trace the molecular and cellular biological processes in tissues. Thus, photoacoustic and thermoacoustic molecular imaging can be outstanding tools for early diagnosis, precise lesion localization, and molecular typing of various diseases. The agents also could be used for therapy in conjugation with drugs or in photothermal therapy, where it functions as an enhancer for the integration of diagnosis and therapy. In this article, we present a detailed review about various exogenous contrast agents for photoacoustic and thermoacoustic molecular imaging. In addition, challenges and future directions of photoacoustic and thermoacoustic molecular imaging in the field of translational medicine are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jain, P. K., Lee, K. S., El-Sayed, I. H., & El-Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,603 · cited 2×
“There are a trend that larger nanoparticles would be more suitable for biological cell imaging applications based on light scattering, while those in the intermediate size range would generate more optical-to-acoustic conversion and then serve as excellent photoabsorbers for laser photothermal therapy and applications…”
BackgroundPhotoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700 · cited 1×
“So far, several variations of photoacoustic imaging have been developed, including Photoacoustic Spectroscopy (PAS), Photoacoustic Tomography (PAT), Photoacoustic Microscopy (PAM), and Photoacoustic Endoscopic imaging (PAE) [2,3].”
MethodHuang, X., Jain, P. K., El-Sayed, I. H., & El-Sayed, M. A. (2007) · Nanomedicine · doi:10.2217/17435889.2.5.681 · Cited by 1,503 · cited 1×
“These nanorods thus make silica-coated gold nanorods a promising imaging and therapeutic nanoagent for photoacoustic imaging and image-guided photothermal therapy [53,54].”
BackgroundPEG-modified gold nanorods with a stealth character for in vivo applications
Niidome, T., Yamagata, M., Okamoto, Y., Akiyama, Y., Takahashi, H., Kawano, T., Katayama, Y., & Niidome, Y. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.06.017 · Cited by 1,200 · cited 1×
“Unfortunately, the plasma resonance absorption peak of nanospheres (520–550 nm) is too limited to be of any use for in vivo applications [57–59].”
BackgroundOn the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
Chen, J., Wang, D., Xi, J., Au, L., Siekkinen, A., Warsen, A., Li, Z.-Y., Zhang, H., Xia, Y., & Li, X. (2007) · Nano Letters · doi:10.1021/nl070345g · Cited by 1,025
Gold Nanocages: From Synthesis to Theranostic Applications
Xia, Y., Li, W., Cobley, C. M., Chen, J., Xia, X., Zhang, Q., Yang, M., Cho, E. C., & Brown, P. K. (2011) · Accounts of Chemical Research · doi:10.1021/ar200061q · Cited by 810 · cited 2×
“therapy [29–31]”
BackgroundGold nanostars: surfactant-free synthesis, 3D modelling, and two-photon photoluminescence imaging
Yuan, H., Khoury, C. G., Hwang, H., Wilson, C. M., Grant, G. A., & Vo-Dinh, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/7/075102 · Cited by 777 · cited 1×
“The plasmon resonant wavelength correlates with the branching [34].”
BackgroundObservation of a Quadrupole Plasmon Mode for a Colloidal Solution of Gold Nanoprisms
Millstone, J. E., Park, S., Shuford, K. L., Qin, L., Schatz, G. C., & Mirkin, C. A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043245a · Cited by 756 · cited 1×
“It is well-known that the plasmon resonance of metal nanoparticles is highly sensitive to the nanoparticle size, shape, and dielectric properties of the surrounding medium [56,57].”
Background
Cited by
Compound Copper Chalcogenide Nanocrystals
Coughlan, C., Ibáñez, M., Dobrozhan, O., Singh, A., Cabot, A., & Ryan, K. M. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00376 · Cited by 930
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Photoacoustic tomography of blood oxygenation: A mini review
Li, M., Tang, Y., & Yao, J. (2018) · Photoacoustics · doi:10.1016/j.pacs.2018.05.001 · Cited by 359
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Recent advances in different modal imaging-guided photothermal therapy
Chen, Q., Wen, J., Li, H., Xu, Y., Liu, F., & Sun, S. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.08.022 · Cited by 265
Photoacoustic Probes for Ratiometric Imaging of Copper(II)
Li, H., Zhang, P., Smaga, L. P., Hoffman, R. A., & Chan, J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b10504 · Cited by 239
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
“Photoacoustic tomography (PAT or PAI) (58, 113, 114) combines ultrasonic resolution with electromagnetic-enhanced contrast to obtain quantitative information on tissue structure, blood flow, and perfusion, and, through targeted probes (59), on receptor status or enzyme activity.”
MethodThapa Magar, T. B., Shrestha, R., Gurung, P., Lim, J., & Kim, Y.-W. (2022) · Processes · doi:10.3390/pr10112215 · Cited by 8
Metadata
- Authors
- Wu, D., Huang, L., Jiang, M., & Jiang, H.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2014-12-18
- Volume
- 15
- Issue
- 12
- Pages
- 23616-23639
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W2055757912
- Cited by
- 191
- References
- 56
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.