PDMS-Based Microfluidic Devices for Cell Culture
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Microfluidic technology has affirmed itself as a powerful tool in medical and biological research by offering the possibility of managing biological samples in tiny channels and chambers. Among the different applications, the use of microfluidics for cell cultures has attracted much interest from scientists worldwide. Traditional cell culture methods need high quantities of samples and reagents that are strongly reduced in miniaturized systems. In addition, the microenvironment is better controlled by scaling down. In this paper, we provide an overview of the aspects related to the design of a novel microfluidic culture chamber, the fabrication approach based on polydimethylsiloxane (PDMS) soft-lithography, and the most critical issues in shrinking the size of the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995 · cited 1×
“Indeed, microfluidic technology allows for microculture systems to substitute traditional petri dishes and flasks [4,5].”
BackgroundOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027 · cited 1×
“Indeed, despite the advantages that are introduced, there are several challenges to deal with in the transition from macroscopic to microfluidic cell cultures [8].”
BackgroundGut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750 · cited 1×
“Another example of organ functions being mimicked at the microscale is the gut model proposed by Kim and Ingber [33].”
BackgroundBiological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719 · cited 1×
“However, some works have shown how some uncross-linked monomers may move from the polymer to the medium and interact with hydrophobic parts of the cell membrane [70].”
BackgroundMicrofluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625 · cited 1×
“In particular, the possibility of mimicking microvasculature has been recently demonstrated [74].”
BackgroundA liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Cited by
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Advances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Metadata
- Authors
- Torino, S., Corrado, B., Iodice, M., & Coppola, G.
- Venue
- Inventions
- Publisher
- MDPI AG
- Published
- 2018-09-06
- Volume
- 3
- Issue
- 3
- Pages
- 65
- ISSN
- 2411-5134 (ISSN-L)
- OpenAlex
- W2891845500
- Cited by
- 157
- References
- 14
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PDMS-Based Microfluidic Devices for Cell Culture. https://app.cochat.ai/papers/10.3390/inventions3030065
- The paper
- Torino, S., Corrado, B., Iodice, M., & Coppola, G. (2018). PDMS-Based Microfluidic Devices for Cell Culture. Inventions. https://doi.org/10.3390/inventions3030065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.