Methylene Blue—Current Knowledge, Fluorescent Properties, and Its Future Use
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Methylene blue is a fluorescent dye discovered in 1876 and has since been used in different scientific fields. Only recently has methylene blue been used for intraoperative fluorescent imaging. Here, the authors review the emerging role of methylene blue, not only as a dye used in clinical practice, but also as a fluorophore in a surgical setting. We discuss the promising potential of methylene blue together with the challenges and limitations among specific surgical techniques. A literature review of PubMed and Medline was conducted based on the historical, current and future usage of methylene blue within the field of medicine. We reviewed not only the current usage of methylene blue, but we also tried to grasp its’ function as a fluorophore in five main domains. These domains include the near-infrared imaging visualization of ureters, parathyroid gland identification, pancreatic tumors imaging, detection of breast cancer tumor margins, as well as breast cancer sentinel node biopsy. Methylene blue is used in countless clinical procedures with a relatively low risk for patients. Usage of its fluorescent properties is still at an early stage and more pre-clinical, as well as clinical research, must be performed to fully understand its potentials and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technical Details of Intraoperative Lymphatic Mapping for Early Stage Melanoma
Morton, D. L. (1992) · Archives of Surgery · doi:10.1001/archsurg.1992.01420040034005 · Cited by 4,371
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423 · cited 1×
“spectrum is about 800 nm, with 5-ALA has a spectrum of about 510 nm, outside of the NIR fluorescence range [38,39].”
BackgroundImage-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466 · cited 1×
“The wavelength of this light is a longer one [31].”
BackgroundSchaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
The ‘Holy Plane’ of Rectal Surgery
Heald, R. J. (1988) · Journal of the Royal Society of Medicine · doi:10.1177/014107688808100904 · Cited by 804
Observations on a “sentinel node” in cancer of the parotid
Gould, E. A., Winship, T., Philbin, P. H., & Kerr, H. H. (1960) · Cancer · doi:10.1002/1097-0142(196001/02)13:1<77::aid-cncr2820130114>3.0.co;2-d · Cited by 447
Cellular and molecular actions of Methylene Blue in the nervous system
Oz, M., Lorke, D. E., Hasan, M., & Petroianu, G. A. (2011) · Medicinal Research Reviews · doi:10.1002/med.20177 · Cited by 443 · cited 2×
“Many studies describe in detail the mechanisms of MB at the molecular level [19,29].”
BackgroundMethodPharmacokinetics and organ distribution of intravenous and oral methylene blue
Peter, C., Hongwan, D., Küpfer, A., & Lauterburg, B. H. (2000) · European Journal of Clinical Pharmacology · doi:10.1007/s002280000124 · Cited by 373 · cited 4×
“Lastly, methylene blue can be used to detect lung nodules during thoracoscopic procedures [6] Interestingly enough, some patients metabolize the methylene blue molecule into a non-fluorescent leucomethylene blue with an unclear impact on the patient [17] Despite all of this, the most traditional use of methylene blue…”
BackgroundMethodInfluentialGinimuge, P., & Jyothi, S. (2010) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/0970-9185.74599 · Cited by 369 · cited 4×
“Methylene blue has an excitation peak of about 700 nm, an excitation wavelength of 668 nm, plus an emission of 688 nm, which is visible to the naked eye [35,36].”
BackgroundInfluentialvan Manen, L., Handgraaf, H. J. M., Diana, M., Dijkstra, J., Ishizawa, T., Vahrmeijer, A. L., & Mieog, J. S. D. (2018) · Journal of Surgical Oncology · doi:10.1002/jso.25105 · Cited by 322
Medications and Glucose-6-Phosphate Dehydrogenase Deficiency: An Evidence-Based Review
Youngster, I., Arcavi, L., Schechmaster, R., Akayzen, Y., Popliski, H., Shimonov, J., Beig, S., & Berkovitch, M. (2010) · Drug Safety · doi:10.2165/11536520-000000000-00000 · Cited by 258
Adverse Effects of Methylene Blue on the Central Nervous System
Vutskits, L., Briner, A., Klauser, P., Gascon, E., Dayer, A. G., Kiss, J. Z., Muller, D., Licker, M. J., & Morel, D. R. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181684be4 · Cited by 187 · cited 1×
“5 mg/kg) to allow for the naked eye to be able to see the enlarged parathyroid glands as they are stained blue, but as mentioned earlier, these doses are associated with many adverse effects and should be used with caution [66,67].”
BackgroundVerbeek, F. P. R., van der Vorst, J. R., Schaafsma, B. E., Swijnenburg, R.-J., Gaarenstroom, K. N., Elzevier, H. W., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L. (2013) · Journal of Urology · doi:10.1016/j.juro.2013.02.3187 · Cited by 176 · cited 2×
“With lower doses of MB used, it is still possible to visualize ureters with NIR fluorescence and reducing the risk of side effects at the same time [47].”
BackgroundUrinary Tract Injures: Recognition and Management
Delacroix, S., & Winters, J. C. (2010) · Clinics in Colon and Rectal Surgery · doi:10.1055/s-0030-1254297 · Cited by 168 · cited 1×
“Intraoperative diagnosis of ureteral injury enables immediate repair and reduces negative consequences on patient’s health [45] Intra-operative localization of the ureter often uses a light ureter catheter, particularly in laparoscopic surgery.”
BackgroundAnaphylactic response to blue dye during sentinel lymph node biopsy
Bézu, C., Coutant, C., Salengro, A., Daraï, É., Rouzier, R., & Uzan, S. (2010) · Surgical Oncology · doi:10.1016/j.suronc.2010.10.002 · Cited by 166 · cited 2×
“[80], anaphylactic reaction to methylene blue dye during sentinel node biopsy is extremely rare.”
BackgroundOccupational Methaemoglobinaemia
Bradberry, S. M. (2003) · Toxicological Reviews · doi:10.2165/00139709-200322010-00003 · Cited by 161
Incidence of Iatrogenic Ureteral Injury After Laparoscopic Colectomy
Palaniappa, N. C. (2012) · Archives of Surgery · doi:10.1001/archsurg.2011.2029 · Cited by 158
Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue
Matsui, A., Tanaka, E., Choi, H. S., Kianzad, V., Gioux, S., Lomnes, S. J., & Frangioni, J. V. (2010) · Surgery · doi:10.1016/j.surg.2009.12.003 · Cited by 157 · cited 6×
“3 mmol/L) of MB used in clinical settings, such as that used during sentinel node biopsy, for instance, presents no fluorescence due to the quenching phenomenon [50].”
BackgroundMethodInfluentialTummers, Q. R. J. G., Verbeek, F. P. R., Schaafsma, B. E., Boonstra, M. C., van der Vorst, J. R., Liefers, G., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L. (2014) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2014.02.225 · Cited by 157 · cited 2×
“Patients can experience slight pain after intravenous injections, which resolves after flushing the access site with saline [59,79].”
BackgroundMethodFluorescence Ureteral Visualization in Human Laparoscopic Colorectal Surgery Using Methylene Blue
Al‐Taher, M., van den Bos, J., Schols, R. M., Bouvy, N. D., & Stassen, L. P. S. (2016) · Journal of Laparoendoscopic & Advanced Surgical Techniques · doi:10.1089/lap.2016.0264 · Cited by 97 · cited 1×
“managed to visualize both ureters in only 5 out of 10 patients [48].”
Photodynamic Antifungal Therapy Against Chromoblastomycosis
Lyon, J. P., Azevedo, C. D. M. P. E. S., Moreira, L. M., de Lima, C. J., & de Resende, M. A. (2011) · Mycopathologia · doi:10.1007/s11046-011-9434-6 · Cited by 95
Photodynamic Therapy of Bacterial and Fungal Biofilm Infections
Biel, M. A. (2010) · Methods in molecular biology · doi:10.1007/978-1-60761-697-9_13 · Cited by 87
Methylene blue fluorescence of the ureter during colorectal surgery
Barnes, T. G., Hompes, R., Birks, J., Mortensen, N. J. M., Jones, O. M., Lindsey, I., Guy, R., George, B. D., Cunningham, C., & Yeung, T. M. (2018) · Surgical Endoscopy · doi:10.1007/s00464-018-6219-8 · Cited by 85 · cited 2×
“Methylene blue has an excitation peak of about 700 nm, an excitation wavelength of 668 nm, plus an emission of 688 nm, which is visible to the naked eye [35,36].”
BackgroundUse of methylene blue and near-infrared fluorescence in thyroid and parathyroid surgery
Hillary, S. L., Guillermet, S., Brown, N. J., & Balasubramanian, S. P. (2017) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-017-1641-2 · Cited by 84 · cited 8×
“Fluorescence of an abnormal parathyroid gland is greater than a normal one [26].”
BackgroundInfluentialvan der Vorst, J. R., Schaafsma, B. E., Verbeek, F. P. R., Swijnenburg, R., Tummers, Q. R. J. G., Hutteman, M., Hamming, J. F., Kievit, J., Frangioni, J. V., van de Velde, C. J. �., et al. (2013) · Head & Neck · doi:10.1002/hed.23384 · Cited by 82
de Koning, S. G. B., Peeters, M.-J. T. F. D. V., Jóźwiak, K., Bhairosing, P. A., & Ruers, T. J. M. (2018) · Clinical Breast Cancer · doi:10.1016/j.clbc.2018.04.004 · Cited by 82
Winer, J. H., Choi, H. S., Gibbs‐Strauss, S. L., Ashitate, Y., Colson, Y. L., & Frangioni, J. V. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0868-8 · Cited by 80 · cited 2×
“showed that by using MB as a fluorescent dye, it can be useful in visualizing insulinoma in NIR light, in an animal model [72].”
BackgroundMethodSlooter, M. D., Janßen, A., Bemelman, W. A., Tanis, P. J., & Hompes, R. (2019) · Techniques in Coloproctology · doi:10.1007/s10151-019-01973-4 · Cited by 76 · cited 1×
“, eight experimental dyes that could be used to identify ureters were described [54].”
BackgroundPołom, K., Murawa, D., Nowaczyk, P., Rho, Y. S., & Murawa, P. (2011) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2011.11.004 · Cited by 72 · cited 1×
“Most cases of serotonin syndrome occurred after doses of 1–8 mg/kg MB via intravenous injection used when trying to visualize the parathyroid glands [34,82] in patients taking these medications.”
Nedu, M.-E., Tertiş, M., Cristea, C., & Georgescu, A. V. (2020) · Diagnostics · doi:10.3390/diagnostics10040223 · Cited by 70 · cited 1×
“Many studies describe in detail the mechanisms of MB at the molecular level [19,29].”
BackgroundIdentifying Ureters In Situ Under Fluorescence During Laparoscopic and Open Colorectal Surgery
Yeung, T. M., Volpi, D., Tullis, I. D. C., Nicholson, G. A., Buchs, N. C., Cunningham, C., Guy, R., Lindsey, I., George, B. D., Jones, O. M., et al. (2015) · Annals of Surgery · doi:10.1097/sla.0000000000001513 · Cited by 56 · cited 1×
“showed that intra-operative concentrations of 1 mg/kg gave the strongest signal [49].”
BackgroundNew method for measuring ICG Rmax with a clearance meter
Shimizu, S., Kamiike, W., Hatanaka, N., Yoshida, Y., Tagawa, K., Miyata, M., & Matsuda, H. (1995) · World Journal of Surgery · doi:10.1007/bf00316992 · Cited by 56 · cited 1×
“spectrum is about 800 nm, with 5-ALA has a spectrum of about 510 nm, outside of the NIR fluorescence range [38,39].”
BackgroundMethylene blue mediated photodynamic therapy for resistant plaque psoriasis.
Salah, M., Samy, N. A., & Fadel, M. (2009) · PubMed · Cited by 48
McWade, M. A., Thomas, G., Nguyen, J. Q., Sanders, M. E., Solórzano, C. C., & Mahadevan-Jansen, A. M. (2019) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2019.01.017 · Cited by 47 · cited 2×
“Incorrect diagnosis of the parathyroid glands during surgery may result in serious complications [55].”
BackgroundZhang, C., Jiang, D., Huang, B., Wang, C., Zhao, L., Xie, X., Zhang, Z., Wang, K., Tian, J., & Luo, Y. (2019) · Technology in Cancer Research & Treatment · doi:10.1177/1533033819894331 · Cited by 46 · cited 2×
“Patients can experience slight pain after intravenous injections, which resolves after flushing the access site with saline [59,79].”
BackgroundTummers, Q. R. J. G., Boonstra, M. C., Frangioni, J. V., van de Velde, C. J. H., Vahrmeijer, A. L., & Bonsing, B. A. (2014) · International Journal of Surgery Case Reports · doi:10.1016/j.ijscr.2014.12.002 · Cited by 31 · cited 1×
“The possibility of using MB in NIR visualizations of paraganglioma with a smaller second lesion not seen by the naked eye has also been identified [76].”
BackgroundSerotonin syndrome following Methylene Blue infusion: a rare complication of antidepressant therapy
Barras, A. C. H., Walder, B., & Seeck, M. (2010) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.172221 · Cited by 23
Real‐time near‐infrared fluorescence imaging mediated by blue dye in breast cancer patients
Jiang, L., Liu, T., Wang, X., Li, J., & Zhao, H. (2020) · Journal of Surgical Oncology · doi:10.1002/jso.25874 · Cited by 19 · cited 1×
“, the authors presented the first cases of sentinel node biopsy using methylene blue together with fluorescence imagining [60].”
BackgroundLymphatic Mapping and Sentinel Lymphadenectomy for Breast Cancer
Chung, A. P., & Giuliano, A. E. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-35955-9.00042-8 · Cited by 11
Cited by
Fluorescence image-guided tumour surgery
Wang, K., Du, Y., Zhang, Z., He, K., Cheng, Z., Yin, L., Dong, D., Li, C., Li, W., Hu, Z., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00017-1 · Cited by 239
Activatable fluorescent probes for real-time imaging-guided tumor therapy
Duan, Q.-J., Zhao, Z.-Y., Zhang, Y.-J., Fu, L., Yuan, Y.-Y., Du, J.-Z., & Wang, J. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114793 · Cited by 166
Metadata
- Authors
- Cwalinski, T., Polom, W., Marano, L., Roviello, G., D’Angelo, A., Cwalina, N., Matuszewski, M., Roviello, F., Jaskiewicz, J., & Polom, K.
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2020-11-02
- Volume
- 9
- Issue
- 11
- Pages
- 3538
- ISSN
- 2077-0383 (ISSN-L)
- OpenAlex
- W3095803259
- Cited by
- 163
- References
- 39
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.