The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting
Open accessAbstract
Developments in selective laser melting (SLM) have enabled the fabrication of periodic cellular lattice structures characterized by suitable properties matching the bone tissue well and by fluid permeability from interconnected structures. These multifunctional performances are significantly affected by cell topology and constitutive properties of applied materials. In this respect, a diamond unit cell was designed in particular volume fractions corresponding to the host bone tissue and optimized with a smooth surface at nodes leading to fewer stress concentrations. There were 33 porous titanium samples with different volume fractions, from 1.28 to 18.6%, manufactured using SLM. All of them were performed under compressive load to determine the deformation and failure mechanisms, accompanied by an in-situ approach using digital image correlation (DIC) to reveal stress–strain evolution. The results showed that lattice structures manufactured by SLM exhibited comparable properties to those of trabecular bone, avoiding the effects of stress-shielding and increasing longevity of implants. The curvature of optimized surface can play a role in regulating the relationship between density and mechanical properties. Owing to the release of stress concentration from optimized surface, the failure mechanism of porous titanium has been changed from the pattern of bottom-up collapse by layer (or cell row) to that of the diagonal (45°) shear band, resulting in the significant enhancement of the structural strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The topological design of multifunctional cellular metals
Evans, A. G., Hutchinson, J. W., Fleck, N. A., Ashby, M. F., & Wadley, H. N. G. (2001) · Progress in Materials Science · doi:10.1016/s0079-6425(00)00016-5 · Cited by 1,134
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292 · cited 1×
“Proximal tibia 4–430 Longitudinal 1–13 [40]”
Cited by
Design and Optimization of Lattice Structures: A Review
Pan, C., Han, Y., & Lu, J. (2020) · Applied Sciences · doi:10.3390/app10186374 · Cited by 640
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
Liu, F., Mao, Z., Zhang, P., Zhang, D. Z., Jiang, J., & Ma, Z. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.09.053 · Cited by 395
Self-citationUnraveling of Advances in 3D-Printed Polymer-Based Bone Scaffolds
Xu, Y., Zhang, F., Zhai, W., Cheng, S., Li, J., & Wang, Y. (2022) · Polymers · doi:10.3390/polym14030566 · Cited by 349
A review on integration of lightweight gradient lattice structures in additive manufacturing parts
Seharing, A., Azman, A. H., & Abdullah, S. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020916951 · Cited by 270
Metadata
- Authors
- Liu, F., Zhang, D., Zhang, P., Zhao, M., & Jafar, S.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2018-03-03
- Volume
- 11
- Issue
- 3
- Pages
- 374
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2790033423
- Cited by
- 173
- References
- 2
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting. https://app.cochat.ai/papers/10.3390/ma11030374
- The paper
- Liu, F., Zhang, D., Zhang, P., Zhao, M., & Jafar, S. (2018). Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting. Materials. https://doi.org/10.3390/ma11030374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.