The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Corrosion of Metallic Biomaterials: A Review
Open accessAbstract
Metallic biomaterials are used in medical devices in humans more than any other family of materials. The corrosion resistance of an implant material affects its functionality and durability and is a prime factor governing biocompatibility. The fundamental paradigm of metallic biomaterials, except biodegradable metals, has been “the more corrosion resistant, the more biocompatible.” The body environment is harsh and raises several challenges with respect to corrosion control. In this invited review paper, the body environment is analysed in detail and the possible effects of the corrosion of different biomaterials on biocompatibility are discussed. Then, the kinetics of corrosion, passivity, its breakdown and regeneration in vivo are conferred. Next, the mostly used metallic biomaterials and their corrosion performance are reviewed. These biomaterials include stainless steels, cobalt-chromium alloys, titanium and its alloys, Nitinol shape memory alloy, dental amalgams, gold, metallic glasses and biodegradable metals. Then, the principles of implant failure, retrieval and failure analysis are highlighted, followed by description of the most common corrosion processes in vivo. Finally, approaches to control the corrosion of metallic biomaterials are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Following implantation of biomaterials and medical devices, the following sequence of local events takes place: injury, blood-material interactions, provisional matrix formation, acute inflammation, chronic inflammation, granulation tissue development, foreign-body reaction (FBR) and fibrosis (fibrous capsule developm…”
BackgroundSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Non-crystalline Structure in Solidified Gold–Silicon Alloys
KLEMENT, W., WILLENS, R. H., & DUWEZ, P. (1960) · Nature · doi:10.1038/187869b0 · Cited by 2,808
Evolution of nanoporosity in dealloying
Erlebacher, J., Aziz, M. J., Karma, A., Dimitrov, N., & Sieradzki, K. (2001) · Nature · doi:10.1038/35068529 · Cited by 2,753
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
An overview of nitinol medical applications
Duerig, T., Pelton, A., & Stöckel, D. (1999) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(99)00294-4 · Cited by 1,628
Brunette, D. M., Tengvall, P., Textor, M., & Thomsen, P. (2001) · Engineering Materials · doi:10.1007/978-3-642-56486-4 · Cited by 1,547
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Self-citationNew Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Corrosion of Metal Orthopaedic Implants*
Jacobs, J. J., Gilbert, J. L., & Urban, R. M. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199802000-00015 · Cited by 967
Corrosion and surface modification on biocompatible metals: A review
Asri, R. I. M., Harun, W. S. W., Samykano, M., Lah, N. A. C., Ghani, S. A. C., Tarlochan, F., & Raza, M. R. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.04.102 · Cited by 775
A review of modified DLC coatings for biological applications
Hauert, R. (2003) · Diamond and Related Materials · doi:10.1016/s0925-9635(03)00081-5 · Cited by 681
Progress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Davies, J. E. (1991) · University of Toronto Press eBooks · doi:10.3138/9781442671508 · Cited by 644
Gilbert, J. L., Buckley, C. A., & Jacobs, J. J. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271210 · Cited by 628
Biomedical applications of diamond‐like carbon coatings: A review
Roy, R. K., & Lee, K. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30768 · Cited by 496
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Inflammatory Responses to Biomaterials
Tang, L., & Eaton, J. W. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.4.466 · Cited by 481
Diamond-like carbon coatings as biocompatible materials—an overview
Grill, A. (2003) · Diamond and Related Materials · doi:10.1016/s0925-9635(03)00018-9 · Cited by 478
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.
Shabalovskaya, S. A. (2002) · PubMed · Cited by 429
Physico-chemical considerations of titanium as a biomaterial
Tengvall, P., & Lundström, I. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90056-y · Cited by 373
Stewart, J., & Williams, D. E. (1992) · Corrosion Science · doi:10.1016/0010-938x(92)90074-d · Cited by 367
A review of investigations on biocompatibility of diamond-like carbon and carbon nitride films
Cui, F. Z., & Li, D. J. (2000) · Surface and Coatings Technology · doi:10.1016/s0257-8972(00)00809-4 · Cited by 365
Ryh�nen, J., Niemi, E., Serlo, W. S., Niemel�, E., Sandvik, P., Pernu, H., & Salo, T. (1997) · Journal of Biomedical Materials Research · Cited by 364
The Prospects of Zinc as a Structural Material for Biodegradable Implants—A Review Paper
Katarivas Levy, G., Goldman, J., & Aghion, E. (2017) · Metals · doi:10.3390/met7100402 · Cited by 340
Urban, R. M., Jacobs, J. J., Gilbert, J. L., & Galante, J. O. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199409000-00009 · Cited by 337
Chapter 4 Mechanisms of inflammation and infection with implanted devices
Anderson, J. M. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90045-4 · Cited by 331
Bulk metallic glasses for biomedical applications
Schroers, J., Kumar, G., Hodges, T. M., Chan, S., & Kyriakides, T. R. (2009) · JOM · doi:10.1007/s11837-009-0128-1 · Cited by 325
REVIEW ARTICLE: Inflammation and Implantation
Dekel, N., Gnainsky, Y., Granot, I., & Mor, G. (2010) · American Journal of Reproductive Immunology · doi:10.1111/j.1600-0897.2009.00792.x · Cited by 302
Aparicio, C., Javier Gil, F., Fonseca, C., Barbosa, M., & Planell, J. A. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00314-9 · Cited by 298
Corrosion of Gold and Amalgam Placed in Contact with Each other
Fusayama, T., Katayori, T., & Nomoto, S. (1963) · Journal of Dental Research · doi:10.1177/00220345630420051301 · Cited by 295
Implant micromotion is related to peak insertion torque and bone density
Trisi, P., Perfetti, G., Baldoni, E., Berardi, D., Colagiovanni, M., & Scogna, G. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01679.x · Cited by 285
Endothelial Cellular Responses to Biodegradable Metal Zinc
Ma, J., Zhao, N., & Zhu, D. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00319 · Cited by 275
Eliaz, N., Shachar, A., Tal, B. H., & Eliezer, D. (2002) · Engineering Failure Analysis · doi:10.1016/s1350-6307(01)00009-7 · Cited by 260
Self-citationCorrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation
Antunes, R. A., & de Oliveira, M. C. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.012 · Cited by 250
Rasouli, R., Barhoum, A., & Uludag, H. (2018) · Biomaterials Science · doi:10.1039/c8bm00021b · Cited by 242
Wang, H., Eliaz, N., Xiang, Z., Hsu, H.-P., Spector, M., & Hobbs, L. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.034 · Cited by 220
Self-citationKirkland, N. T., Birbilis, N., Walker, J., Woodfield, T., Dias, G. J., & Staiger, M. P. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31687 · Cited by 216
Biocompatibility evaluation of nickel-titanium shape memory metal alloy
Ryhänen, J. (1999) · Cited by 197
Laser Processing of Net-Shape NiTi Shape Memory Alloy
Krishna, B. V., Bose, S., & Bandyopadhyay, A. (2007) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-007-9127-4 · Cited by 163
Brief Overview on Nitinol as Biomaterial
Wadood, A. (2016) · Advances in Materials Science and Engineering · doi:10.1155/2016/4173138 · Cited by 162
Eliaz, N., & Eliyahu, M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30944 · Cited by 159
Self-citationJafari, S., Harandi, S. E., & Singh Raman, R. K. (2015) · JOM · doi:10.1007/s11837-015-1366-z · Cited by 158
Evaluation of diamond-like carbon-coated orthopaedic implants
Dowling, D. P., Kola, P. V., Donnelly, K., Kelly, T. C., Brumitt, K., Lloyd, L., Eloy, R., Thèrin, M., & Weill, N. (1997) · Diamond and Related Materials · doi:10.1016/s0925-9635(96)00687-5 · Cited by 156
Eliaz, N., Shmueli, S., Shur, I., Benayahu, D., Aronov, D. A., & Rosenman, G. I. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.04.005 · Cited by 156
Self-citationDegradation of Implant Materials
Eliaz, N. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3942-4 · Cited by 146
Self-citationHamilton, R. F., Bimber, B. A., Andani, M. T., & Elahinia, M. (2017) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2017.06.027 · Cited by 145
Chou, D., Hong, D., Saha, P., Ferrero, J., Lee, B., Tan, Z., Dong, Z., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.025 · Cited by 144
Corrosion and other electrochemical aspects of biomaterials.
Bundy, K. (1994) · PubMed · Cited by 104
Schuhmann, D., Kubicka-Muranyi, M., Mirtcheva, J., Günther, J., Kind, P., & Gleichmann, E. (1990) · The Journal of Immunology · doi:10.4049/jimmunol.145.7.2132 · Cited by 103
REACTION OF BONE TO VARIOUS METALS
Zierold, A. A. (1924) · Archives of Surgery · doi:10.1001/archsurg.1924.01120080133008 · Cited by 102
The Anodic Corrosion of Gold in Concentrated Chloride Solutions
Frankenthal, R. P., & Siconolfi, D. J. (1982) · Journal of The Electrochemical Society · doi:10.1149/1.2124085 · Cited by 84
Laing, P. G. (1973) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30792-6 · Cited by 75
Corrosion and Degradation of Implant Materials: Second Symposium
Fraker, A., & Griffin, C. (1985) · doi:10.1520/stp859-eb · Cited by 73
Čapek, J., Jablonská, E., Lipov, J., Kubatík, T. F., & Vojtěch, D. (2017) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2017.10.008 · Cited by 69
Importance of oxide film in endovascular biodegradable zinc stents
Drelich, A. J., Bowen, P. K., LaLonde, L., Goldman, J., & Drelich, J. W. (2016) · Surface Innovations · doi:10.1680/jsuin.16.00014 · Cited by 59
Assisted deposition of nano-hydroxyapatite onto exfoliated carbon nanotube oxide scaffolds
Zanin, H., Rosa, C. M. R., Eliaz, N., May, P. W., Marciano, F. R., & Lobo, A. O. (2015) · Nanoscale · doi:10.1039/c4nr07317g · Cited by 58
Self-citationCorrosion of surgical implants
Traisnel, M., Maguer, D. L., Hildebrand, H. F., et al. (1990) · Clinical Materials · doi:10.1016/0267-6605(90)90030-y · Cited by 53
A preliminary ferrographic survey of the wear particles in human synovial fluid
Evans, C. H., Mears, D. C., & McKnight, J. L. (1981) · Arthritis & Rheumatism · doi:10.1002/art.1780240708 · Cited by 53
Advances in Metallic Biomaterials
Niinomi, M., Narushima, T., & Nakai, M. (2015) · Springer series in biomaterials science and engineering · doi:10.1007/978-3-662-46842-5 · Cited by 52
The Use of Synthetic Environments for Corrosion Testing
Francis, P. E., & Lee, T. S. (1988) · doi:10.1520/stp970-eb · Cited by 44
A New Ti-5Ag Alloy for Customized Prostheses by Three-dimensional Printing (3DP™)
Hong, S.-B., Eliaz, N., Leisk, G. G., Sachs, E. M., Latanision, R. M., & Allen, S. M. (2001) · Journal of Dental Research · doi:10.1177/00220345010800030301 · Cited by 44
Self-citationThe Role of Inflammatory Pathways in Implantation Failure: Chronic Endometritis and Hydrosalpinges
Akopians, A. L., Pisarska, M. D., & Wang, E. T. (2015) · Seminars in Reproductive Medicine · doi:10.1055/s-0035-1554916 · Cited by 42
Eley, B. M. (1997) · BDJ · doi:10.1038/sj.bdj.4809360 · Cited by 36
Nitinol Properties Affecting Uses in Interventional Radiology
Rabkin, D. J., Lang, E. V., & Brophy, D. P. (2000) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61428-6 · Cited by 31
Hydroxyapatite coatings electrodeposited at near-physiological conditions
Metoki, N., Leifenberg-Kuznits, L., Kopelovitch, W., Burstein, L., Gozin, M., & Eliaz, N. (2014) · Materials Letters · doi:10.1016/j.matlet.2013.12.091 · Cited by 30
Self-citationA REVIEW ON DENTAL AMALGAM CORROSION AND ITS CONSEQUENCES
Fathi, M. H., & Mortazavi, V. (2004) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 30
Hakshur, K., Benhar, I., Bar-Ziv, Y., Halperin, N., Segal, D., & Eliaz, N. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.030 · Cited by 23
Self-citationEliaz, N., & Hakshur, K. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3942-4_10 · Cited by 20
Self-citationMendel, K., Eliaz, N., Benhar, I., Hendel, D., & Halperin, N. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.003 · Cited by 20
Self-citationChen, Y., Huang, P., Chen, H., Wang, S., Wang, H., Guo, J., Zhang, X., Zhang, S., Yan, J. F., Xia, J., et al. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00957 · Cited by 20
Hernández, M. C., Stewart, M., Bonakdarpour, A., Mohseni, M., & Wilkinson, D. P. (2017) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.23073 · Cited by 16
Electrochemical Techniques to Obtain Biofunctional Materials
Hanawa, T. (2011) · Modern aspects of electrochemistry · doi:10.1007/978-1-4614-0347-0_5 · Cited by 4
Cited by
Svetlizky, D., Das, M., Zheng, B., Vyatskikh, A. L., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.020 · Cited by 1,371
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
The role and significance of Magnesium in modern day research-A review
Prasad, S. V. S., Prasad, S. B., Verma, K., Mishra, R. K., Kumar, V., & Singh, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.05.012 · Cited by 683
The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
Kligman, S., Ren, Z., Chung, C.-H., Perillo, M. A., Chang, Y.-C., Koo, H., Zheng, Z., & Li, C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10081641 · Cited by 387
Laser-based directed energy deposition (DED-LB) of advanced materials
Svetlizky, D., Zheng, B., Vyatskikh, A., Das, M., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2022) · Materials Science and Engineering: A · doi:10.1016/j.msea.2022.142967 · Cited by 331
Self-citation
Metadata
- Authors
- Eliaz, N.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2019-01-28
- Volume
- 12
- Issue
- 3
- Pages
- 407
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2913840193
- Cited by
- 984
- References
- 74
- FWCI
- 32.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.