The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A Review of Conductive Hydrogel Used in Flexible Strain Sensor
Open accessAbstract
Hydrogels, as classic soft materials, are important materials for tissue engineering and biosensing with unique properties, such as good biocompatibility, high stretchability, strong adhesion, excellent self-healing, and self-recovery. Conductive hydrogels possess the additional property of conductivity, which endows them with advanced applications in actuating devices, biomedicine, and sensing. In this review, we provide an overview of the recent development of conductive hydrogels in the field of strain sensors, with particular focus on the types of conductive fillers, including ionic conductors, conducting nanomaterials, and conductive polymers. The synthetic methods of such conductive hydrogel materials and their physical and chemical properties are highlighted. At last, challenges and future perspectives of conductive hydrogels applied in flexible strain sensors are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Synthesis, properties, and biomedical applications of gelatin methacryloyl (GelMA) hydrogels
Yue, K., Trujillo-de Santiago, G., Alvarez, M. M., Tamayol, A., Annabi, N., & Khademhosseini, A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.045 · Cited by 3,146 · cited 1×
“As a soft and wet material, hydrogels with unique properties of swelling behavior, flexibility, good biocompatibility and porosity, have demonstrated their versatility in many research and industry fields, including biomedical engineering [10,11], sensor and actuator [12,13], agriculture and wastewater treatment [14,1…”
BackgroundA flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Han, L., Yan, L., Wang, M., Wang, K., Fang, L., Zhou, J., Fang, J., Ren, F., & Lu, X. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b01446 · Cited by 438
Xia, S., Song, S., Jia, F., & Gao, G. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01039d · Cited by 349
Xia, S., Song, S., & Gao, G. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.08.053 · Cited by 259 · cited 3×
“Xia and co-workers prepared a dual physically cross-linked P(AAm-co-LMA)/alginate DN hydrogel based on the first P(AAm-co-LMA) network crosslinked by core-shell hybrid nanoparticles and the second alginate network cross-linked by Ca2+ [46].”
BackgroundInfluentialPan, X., Wang, Q., Ning, D., Dai, L., Liu, K., Ni, Y., Chen, L., & Huang, L. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00657 · Cited by 228 · cited 1×
“Guar gum Na2B4O7 Conductivity, antifreeze, adhesion [51]”
Cited by
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Multifunctional conductive hydrogels and their applications as smart wearable devices
Chen, Z., Chen, Y., Hedenqvist, M. S., Chen, C., Cai, C., Li, H., Liu, H., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02929g · Cited by 323
Production of Polymer Hydrogel Composites and Their Applications
El Sayed, M. M. (2023) · Journal of Polymers and the Environment · doi:10.1007/s10924-023-02796-z · Cited by 268
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Metadata
- Authors
- Tang, L., Wu, S., Qu, J., Gong, L., & Tang, J.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2020-09-07
- Volume
- 13
- Issue
- 18
- Pages
- 3947
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W3083544641
- Cited by
- 223
- References
- 9
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Conductive Hydrogel Used in Flexible Strain Sensor. https://app.cochat.ai/papers/10.3390/ma13183947
- The paper
- Tang, L., Wu, S., Qu, J., Gong, L., & Tang, J. (2020). A Review of Conductive Hydrogel Used in Flexible Strain Sensor. Materials. https://doi.org/10.3390/ma13183947
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.