Bond-Slip Performances of Ultra-High Performance Concrete Steel Tube Columns Made of a Large-Diameter Steel Tube with Internally Welded Steel Bars

Open access

The DOI matches its Crossref record; 35 of the 37 references it cites were found in a registry or an index; 2 of the 41 sources its claims cite were checked for support.

Abstract

Large-diameter concrete-filled steel tube (CFST) members are being increasingly utilised owing to their ability to carry larger loads and resist bending. Upon incorporating ultra-high-performance concrete (UHPC) into steel tubes, the resulting composite structures are lighter in weight and much stronger than conventional CFSTs. The interfacial bond between the steel tube and UHPC is crucial for the two materials to effectively work together. This study aimed to investigate the bond-slip performance of large-diameter UHPC steel tube columns and the effect of internally welded steel bars in steel tubes on the interfacial bond-slip performance between the steel tubes and UHPC. Five large-diameter UHPC-filled steel tube columns (UHPC-FSTCs) were fabricated. The interiors of the steel tubes were welded to steel rings, spiral bars, and other structures and filled with UHPC. The effects of different construction measures on the interfacial bond-slip performance of UHPC-FSTCs were analysed through push-out tests, and a method for calculating the ultimate shear bearing capacities of the interfaces between steel tubes containing welded steel bars and UHPC was proposed. The force damage to UHPC-FSTCs was simulated by establishing a finite element model using ABAQUS. The results indicate that the use of welded steel bars in steel tubes can considerably improve the bond strength and energy dissipation capacity of the UHPC-FSTC interface. R2 exhibited the most effective constructional measures, resulting in a significant increase in ultimate shear bearing capacity by a factor of approximately 50 and energy dissipation capacity by a factor of approximately 30 compared to R0 without any constructional measures. The load-slip curve and ultimate bond strength obtained from finite element analysis and the interface ultimate shear bearing capacities of the UHPC-FSTCs obtained using the calculation method agreed well with the test results. Our results provide a reference for future research on the mechanical properties of UHPC-FSTCs and their engineering applications.

Overview

CoChat Summary

## TL;DR

This paper tested five large-diameter UHPC-filled steel tube columns with different internally welded steel-bar layouts using push-out experiments, then validated a finite element model and a calculation method for ultimate interface bearing capacity. The welded internal steel bars substantially improved bond strength and energy dissipation, with specimen R2 performing best.

## Key findings

  • Five UHPC-FSTCs were tested; the specimens had a 370 mm steel-tube diameter, 10 mm wall thickness, and 550 mm height, and the UHPC cube strength averaged 132.05 MPa with an elastic modulus of 51,081.46 MPa.
  • Adding welded steel bars greatly improved interface performance: compared with R0, R1 increased bearing capacity 24-fold and energy dissipation 15-fold; R2 doubled both relative to R1; R3 had similar bond strength to R2, with bearing capacity about 7% higher and energy dissipation 14% lower than R2.
  • The paper states R2 was the best configuration overall, with about 50 times higher load-bearing capacity and 30 times higher energy dissipation capacity than R0.
  • The finite element model matched experiments well; the average error between simulated and tested ultimate bearing capacity was 4.91%, and the calculated-to-test ratio for interface capacity was 0.98–1.05 with an average of 1.001.

## Methods

  • Design: Push-out tests on five large-diameter UHPC-filled steel tube columns with different internally welded steel-bar constructions (steel rings and spiral bars).
  • Data/sample: Steel tube diameter 370 mm, thickness 10 mm, height 550 mm; loading was displacement-controlled at 0.5 mm/min until 40 mm loaded-end displacement. Strain gauges and LVDTs/RVDTs measured strain and slip.
  • Analysis: Load-slip curves, bond strength, and energy dissipation were evaluated; an ABAQUS finite element model used shell/truss/solid elements and cohesive contact, and a formula for ultimate interface bearing capacity was proposed and checked against tests.

## Limitations

  • The paper explicitly says that, because of a lack of relevant research, further experiments and numerical simulations are required to verify the applicability of the equation in additional cases.
  • Evident from the text: the study tested only five specimens and one large-diameter geometry, so generalization beyond the reported configurations is limited.
  • Evident from the text: the paper’s own discussion notes possible test deviations from inhomogeneity during filling and slight cracking of the reinforcement weld, which may affect measured results.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/ma16103836

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Design drawings depicting the measurements used to construct the specimens (all dimensions are in mm) (a) R0; (b) R1; (c) R2; (d) R3; (e) RS; (f) Top view.
Figure 1 Design drawings depicting the measurements used to construct the specimens (all dimensions are in mm) (a) R0; (b) R1; (c) R2; (d) R3; (e) RS; (f) Top view.CC BY · PubMed Central
Figure 2 Fabricated UHPC-FSTC specimens (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.
Figure 2 Fabricated UHPC-FSTC specimens (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.CC BY · PubMed Central
Figure 3 Loading test setup (a) Loading test setup; (b) Two-dimensional schematic of the loading test setup; (c) Three-dimensional schematic of the loading test setup.
Figure 3 Loading test setup (a) Loading test setup; (b) Two-dimensional schematic of the loading test setup; (c) Three-dimensional schematic of the loading test setup.CC BY · PubMed Central
Figure 4 The layout of the measurement sensors (all dimensions are in mm) (a) Front view; (b) Top view.
Figure 4 The layout of the measurement sensors (all dimensions are in mm) (a) Front view; (b) Top view.CC BY · PubMed Central
Figure 5 Failure pattern of specimen (a) R0; (b) R1; (c) R2; (d) R3; (e) R4.
Figure 5 Failure pattern of specimen (a) R0; (b) R1; (c) R2; (d) R3; (e) R4.CC BY · PubMed Central
Figure 6 Load-slip (P-S) curves (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.
Figure 6 Load-slip (P-S) curves (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.CC BY · PubMed Central
Figure 7 Longitudinal strain on the outer wall of each steel tube specimen (all dimensions are in mm).
Figure 7 Longitudinal strain on the outer wall of each steel tube specimen (all dimensions are in mm).CC BY · PubMed Central
Figure 8 Finite element model of (a) Core concrete; (b) Steel tube; (c) R1 steel bar; (d) R2 steel bar; (e) R3 steel bar; (f) RS steel bar.
Figure 8 Finite element model of (a) Core concrete; (b) Steel tube; (c) R1 steel bar; (d) R2 steel bar; (e) R3 steel bar; (f) RS steel bar.CC BY · PubMed Central
Figure 9 Bilinear cohesion model.
Figure 9 Bilinear cohesion model.CC BY · PubMed Central
Figure 10 Cohesion of the inner walls of the steel tubes. (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.
Figure 10 Cohesion of the inner walls of the steel tubes. (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.CC BY · PubMed Central
Figure 11 Comparison between the P-S curves obtained using the simulation and test results (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.
Figure 11 Comparison between the P-S curves obtained using the simulation and test results (a) R0; (b) R1; (c) R2; (d) R3; (e) RS.CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 0 Not valid · 19 Not checked · 83 Own results and interpretations

38 more claims

Create a free account to see all 103 claims and to verify the 8 references still open.

See all claims — free account
  • Probably not a substantial claim. 19
  • It may state two separate claims as one. 47
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 35 references

Research works printed but not linked: 8

  1. Gao C.Y. Yuan M.M. Wang J.L. Sun K.Q. Zhao N. Research on interfacial bond-slip mechanical properties of ultra-high performance concrete filled steel tube Build. Struct. 2022 52 1369 1374 10.19701/j.jzjg.22S2178 · doi:10.19701/j.jzjg.22s2178
  2. Wang Q.W. Liu L. Shi Q.X. Wang P. A calculation method of interface bond strength of reactive powder concrete filled in steel tubes Eng. Mech. 2020 37 41 50 10.6052/j.issn.1000-4750.2019.04.0236 · doi:10.6052/j.issn.1000-4750.2019.04.0236
  3. Wang Q.W. Shi Q.X. Xu Z.D. Zhang C.Y. Interface bond-slip behavior of reactive powder concrete-filled circular steel tube J. Build. Struct. 2021 42 210 218 10.14006/j.jzjgxb.2020.0057 · doi:10.14006/j.jzjgxb.2020.0057
  4. Chen L.H. Dai J.X. Jin Q.L. Sheng B.L. Push-out test study on the bond strength between square checkered steel tube and concrete Build. Struct. 2015 45 17 20+26 10.19701/j.jzjg.2015.03.004 · doi:10.19701/j.jzjg.2015.03.004
  5. GB/T228.1–2010 Metallic Materials-Tensile Testing—Part 1: Method of Test at Room Temperature China Standard Press Beijing, China 2010 (In Chinese)
  6. GB/T 50081–2002 Standard for Test Method of Mechanical Properties on Ordinary Concrete China Standard Press Beijing, China 2013 (In Chinese)
  7. Zhang G.C. Guo C.Q. Yan Z.K. Zhou Y. Zuo X.Q. Quasi-Static Compression Deformation Mode, Mechanical Property and Energy Absorption Performance of Steel Foam Filled Tubes Mater. Rev. 2021 35 24158 24163
  8. Liu W. Interfacial failure analysis based on cohesive zone model Comput. Aided Eng. 2013 22 456 460

Cited by

Metadata

Authors
Deng, N., Zhao, H., Yao, D., & Tang, Z.
Affiliations
Guangxi University (CN)
Corresponding author
  • Deng, Nianchun
  • Tang, Zhiyu
Venue
Materials
Publisher
MDPI AG
Published
2023-05-19
Volume
16
Issue
10
Pages
3836
ISSN
1996-1944 (ISSN-L)
OpenAlex
W4377092310
Cited by
14
References
37
Citations by year
2026: 5 · 2025: 4 · 2024: 3 · 2023: 2
FWCI
1.63
Type
journal article
Language
en
Open access
Locations
  • Materials (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • National Natural Science Foundation of China (52268048, 51868006, AA22068066)
  • Guangxi Science and Technology Major Project of China (52268048, 51868006, AA22068066)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
  • Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
  • Physical Sciences › Engineering › Civil and Structural Engineering › Fire effects on concrete materials
Keywords
ultra-high performance concrete, concrete-filled steel tube columns, bond-slip behavior, interfacial strength, steel rings, push-out test, energy dissipation, composite columns, finite element analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.