Recent Progress in Microfluidic Models of the Blood-Brain Barrier
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The blood-brain barrier (BBB) is a critical physical and chemical barrier that maintains brain homeostasis. Researchers in academia and industry are highly motivated to develop experimental models that can accurately mimic the physiological characteristics of the BBB. Microfluidic systems, which manipulate fluids at the micrometer scale, are ideal tools for simulating the BBB microenvironment. In this review, we summarized the progress in the design and evaluation of microfluidic in vitro BBB models, including advances in chip materials, porous membranes, the use of endothelial cells, the importance of shear stress, the detection specific markers to monitor tight junction formation and integrity, measurements of TEER and permeability. We also pointed out several shortcomings of the current microfluidic models. The purpose of this paper is to let the readers understand the characteristics of different types of model design, and select appropriate design parameters according to the research needs, so as to obtain the best experimental results. We believe that the microfluidics BBB models will play an important role in neuroscience and pharmaceutical research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blood–brain barrier breakdown in Alzheimer disease and other neurodegenerative disorders
Sweeney, M. D., Sagare, A. P., & Zlokovic, B. V. (2018) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.188 · Cited by 3,076
The Neurovascular Unit Coming of Age: A Journey through Neurovascular Coupling in Health and Disease
Iadecola, C. (2017) · Neuron · doi:10.1016/j.neuron.2017.07.030 · Cited by 2,480
Preclinical research: Make mouse studies work
Perrin, S. (2014) · Nature · doi:10.1038/507423a · Cited by 668 · cited 1×
“More than 80% of results obtained from animal models do not correspond in a straightforward way to human responses [25].”
BackgroundThe blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662 · cited 2×
“In the physiological state, shear stress is 10–20 dynes·cm−2 in a 10 μm-diameter capillary [90].”
BackgroundClaudin-5: gatekeeper of neurological function
Greene, C., Hanley, N., & Campbell, M. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0123-z · Cited by 583
Organotypic brain slice cultures: A review
Humpel, C. (2015) · Neuroscience · doi:10.1016/j.neuroscience.2015.07.086 · Cited by 480 · cited 1×
“In these models, organotypic hippocampal slices are cultured on a membrane surface and used to study the BBB functions under different physiological and pathological conditions [31,32].”
Crossing the Blood–Brain Barrier: Recent Advances in Drug Delivery to the Brain
Patel, M. M., & Patel, B. M. (2017) · CNS Drugs · doi:10.1007/s40263-016-0405-9 · Cited by 430 · cited 1×
“Finally, large molecules such as insulin, transferrin, leptin, albumin, and tumor necrosis factor alpha (TNFα) are passed through the BBB by receptor-mediated transport, adsorption-mediated transcytosis, and active efflux transporters [90,98].”
BackgroundRole of Blood-Brain Barrier in Alzheimer’s Disease
Cai, Z., Qiao, P.-F., Wan, C.-Q., Cai, M., Zhou, N.-K., & Li, Q. (2018) · Journal of Alzheimer's Disease · doi:10.3233/jad-180098 · Cited by 370 · cited 1×
“The blood-brain barrier (BBB) is a highly selective barrier that regulates passive and active transport between the brain parenchyma and peripheral blood [1,2].”
BackgroundKidney-on-a-Chip technology for drug-induced nephrotoxicity screening
Wilmer, M. J., Ng, C. P., Lanz, H. L., Vulto, P., Suter-Dick, L., & Masereeuw, R. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.11.001 · Cited by 354 · cited 1×
“Microfluidic devices are evolving rapidly, and it is now possible to design microphysiologic organ-on-a chip models for guts, lungs, kidney, and other organs [49,50].”
BackgroundMicrofluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Cited by
Yan, L., Guo, M.-S., Zhang, Y., Yu, L., Wu, J.-M., Tang, Y., Ai, W., Zhu, F.-D., Law, B. Y.-K., Chen, Q., et al. (2022) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2022/5288698 · Cited by 97
Current Status of In vitro Models of the Blood-brain Barrier
Dong, X., & Shah, B. (2022) · Current Drug Delivery · doi:10.2174/1567201819666220303102614 · Cited by 42
Tanaka, M., Araujo, A. C., Valenti, V. E., Guiguer, E. L., Catharin, V. C. S., Gualhardi, C. M., de Souza Bastos Mazuqueli Pereira, E., de Alvares Goulart, R., de Argolo Haber, R. S., de Carvalho, A. C. A., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27052370 · Cited by 13
Metadata
- Authors
- Jiang, L., Li, S., Zheng, J., Li, Y., & Huang, H.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2019-06-05
- Volume
- 10
- Issue
- 6
- Pages
- 375
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W2955572369
- Cited by
- 96
- References
- 13
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.