CoChat

NePCM Based on Silver Dispersions in Poly(Ethylene Glycol) as a Stable Solution for Thermal Storage

Open access

The DOI matches its Crossref record; 100 of the 102 references it cites were found in a registry or an index.

Abstract

The main objective of this study is to design and characterize silver suspensions based on poly(ethylene glycol) PEG400, Ag/PEG400, as energy storage media for low-temperature applications. A polyvinylpyrrolidone (PVP) treatment was applied to ~22 nm silver nanoparticles to ensure good stability in poly(ethylene glycol). An array of different experimental techniques was utilized to analyze the molecular mass and purity of base poly(ethylene glycol), morphology of dry PVP-capped Ag nanoparticles, hydrodynamic average size of dispersed Ag particles, as well as thermal stability of PEG400 and Ag/PEG400 dispersions. Samples exhibited good temporal stabilities with average hydrodynamic diameter around 50 nm according to dynamic light scattering analyses. Melting and solidification transitions were investigated in terms of temperature and enthalpy from differential scanning calorimeter (DSC) thermograms. The thermophysical characterization was completed with thermal conductivity (k), dynamic viscosity (η), isobaric heat capacity (Cp), density (ρ), and surface tension (σ) measurements of designed materials using a Hot Disk thermal conductivimeter, a rotational rheometer, a DSC calorimeter working with a quasi-isothermal modulated method, a U-tube densimeter and a drop shape analyzer, respectively. For a nanoparticle loading of only 1.1% in mass, sub-cooling reduced by 7.1% and thermal conductive improved by 3.9%, with almost no penalization in dynamic viscosity (less than 5.4% of increase). Maximum modifications in Cp, ρ, and σ were 0.9%, 2.2%, and 2.2%, respectively. Experimental results were compared with the values provided by using different theoretical or semi-empirical equations. In particular, good descriptions of dynamic viscosity as functions of temperature and nanoparticle volume concentration were obtained by using the Vogel–Fulcher–Tammann equation and a first-order polynomial η( ϕ v , n p ) correlation, with absolute average deviations of 2.2% and 0.55%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/nano10010019

Cites

100 of 100 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Absorption UV–Vis spectrum of diluted silver dispersion based on PEG400.
Figure 1 Absorption UV–Vis spectrum of diluted silver dispersion based on PEG400.CC BY · PubMed Central
Figure 2 Scanning transmission electron microscope images of DS0476 silver nanoparticles capped with polyvinylpyrrolidone at two different magnifications.
Figure 2 Scanning transmission electron microscope images of DS0476 silver nanoparticles capped with polyvinylpyrrolidone at two different magnifications.CC BY · PubMed Central
Figure 3 Positive-ion mode electrospray ionization (ESI) spectrum of PEG400.
Figure 3 Positive-ion mode electrospray ionization (ESI) spectrum of PEG400.CC BY · PubMed Central
Figure 4 (—) weight loss, TGA, and (- - -) differential weight loss, dTGA, thermograms of (a) base fluid PEG400 and (b) 1.1 wt% Ag/PEG400 nano-enhanced phase change materials.
Figure 4 (—) weight loss, TGA, and (- - -) differential weight loss, dTGA, thermograms of (a) base fluid PEG400 and (b) 1.1 wt% Ag/PEG400 nano-enhanced phase change materials.CC BY · PubMed Central
Figure 5 (a) Nanoparticle size distribution of static sample based on dynamic light scattering measurements: zero day (—), 7th day (- - -), and 26th day (- · - ·). (b) Temporal evolution of average nanoparticle size in Ag(0.01 wt%)/PEG400 dispersion under shaken and static conditions.
Figure 5 (a) Nanoparticle size distribution of static sample based on dynamic light scattering measurements: zero day (—), 7th day (- - -), and 26th day (- · - ·). (b) Temporal evolution of average nanoparticle size in Ag(0.01 wt%)/PEG400 dispersion under shaken and static conditions.CC BY · PubMed Central
Figure 6 DSC cooling and heating thermograms obtained for base fluid and different Ag/PEG400 NePCMs at scanning rates of 2 K·min−1.
Figure 6 DSC cooling and heating thermograms obtained for base fluid and different Ag/PEG400 NePCMs at scanning rates of 2 K·min−1.CC BY · PubMed Central
Figure 7 Temperature dependence of isobaric heat capacity of (×) PEG400, (○) dry Ag nanoparticles, and (□) Ag(0.50 wt%)/PEG400 nanofluid. (·····) Second-order polynomial fitting and (—) values provided for Ag(0.50 wt%)/PEG400 by using Equation (1).
Figure 7 Temperature dependence of isobaric heat capacity of (×) PEG400, (○) dry Ag nanoparticles, and (□) Ag(0.50 wt%)/PEG400 nanofluid. (·····) Second-order polynomial fitting and (—) values provided for Ag(0.50 wt%)/PEG400 by using Equation (1).CC BY · PubMed Central
Figure 8 Temperature dependence of thermal conductivity for pure PEG400 (×) and the Ag/PEG400 nanofluids: (△) 0.10 wt%, (□) 0.50 wt% and (◇) 1.1 wt%. Error bars indicate 5% uncertainty regarding experimental data.
Figure 8 Temperature dependence of thermal conductivity for pure PEG400 (×) and the Ag/PEG400 nanofluids: (△) 0.10 wt%, (□) 0.50 wt% and (◇) 1.1 wt%. Error bars indicate 5% uncertainty regarding experimental data.CC BY · PubMed Central
Figure 9 Relative thermal conductivity, knf/kbf, as a function of volume fraction, ϕv,np, for Ag/PEG400 nanofluids at 313.15 K. (●) Experimental results obtained in this work and predicted values by (- - -) Maxwell [74] and (—) Murshed et al. [80] models.
Figure 9 Relative thermal conductivity, knf/kbf, as a function of volume fraction, ϕv,np, for Ag/PEG400 nanofluids at 313.15 K. (●) Experimental results obtained in this work and predicted values by (- - -) Maxwell [74] and (—) Murshed et al. [80] models.CC BY · PubMed Central
Figure 10 Temperature dependence of density (ρ) for: (×) base PEG400, (△) 0.10 wt%, (□) 0.50 wt%, and (◇) 1.1 wt% NePCMs. (—) Second-order polynomial fittings. Values reported for (+) PEG400 by Han et al. [88] and for (*) PEG600 by Trivedi, Bhanot and Pandey [86].
Figure 10 Temperature dependence of density (ρ) for: (×) base PEG400, (△) 0.10 wt%, (□) 0.50 wt%, and (◇) 1.1 wt% NePCMs. (—) Second-order polynomial fittings. Values reported for (+) PEG400 by Han et al. [88] and for (*) PEG600 by Trivedi, Bhanot and Pandey [86].CC BY · PubMed Central
Figure 11 (a,b) Relationship between shear stress and shear rate at (a) 278 K and (b) 343 K. (c) Temperature dependence of dynamic viscosity. (×) base PEG400, 0 wt%; (△) 0.1 wt%; (□) 0.5 wt%; and (◇) 1.1 wt% Ag/PEG400 NePCMs. (—) Linear fittings, in (a,b); or VTF equation, Equation (6), in (c).
Figure 11 (a,b) Relationship between shear stress and shear rate at (a) 278 K and (b) 343 K. (c) Temperature dependence of dynamic viscosity. (×) base PEG400, 0 wt%; (△) 0.1 wt%; (□) 0.5 wt%; and (◇) 1.1 wt% Ag/PEG400 NePCMs. (—) Linear fittings, in (a,b); or VTF equation, Equation (6), in (c).CC BY · PubMed Central
Figure 12 Viscosity ratios ηnf/ηbf vs. silver nanoparticles volume fraction, (ϕv, np) at 313.15 K. (◇), experimental values; (·····) Einstein; (—) Equations (7) and (8). Error bars indicate 2% uncertainty.
Figure 12 Viscosity ratios ηnf/ηbf vs. silver nanoparticles volume fraction, (ϕv, np) at 313.15 K. (◇), experimental values; (·····) Einstein; (—) Equations (7) and (8). Error bars indicate 2% uncertainty.CC BY · PubMed Central
Figure 13 (a) Temperature dependence of surface tension: (×) base fluid, (△) 0.10 wt%, (□) 0.50 wt%, and (◇) 1.1 wt% nanoparticle concentrations of Ag/PEG400 nanofluids. (—) First–order polynomial fittings. (b) Average modifications in surface tension regarding base fluid, i.e., (σnf–σbf)/σbf.
Figure 13 (a) Temperature dependence of surface tension: (×) base fluid, (△) 0.10 wt%, (□) 0.50 wt%, and (◇) 1.1 wt% nanoparticle concentrations of Ag/PEG400 nanofluids. (—) First–order polynomial fittings. (b) Average modifications in surface tension regarding base fluid, i.e., (σnf–σbf)/σbf.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Rodríguez-Pérez M. Reglero J. Lehmhus D. Wichmann M. De Saja J. Fernández A. The Transient Plane Source Technique (TPS) to Measure Thermal Conductivity and its Potential as A Tool to Detect In-Homogeneities in Metal Foams Proceedings of the International Conference “Advanced Metallic Materials” Smolenice, Slovakia 5–7 November 2003 253 257

Cited by

See all 46

Metadata

Authors
Marcos, M. A., Cabaleiro, D., Hamze, S., Fedele, L., Bobbo, S., Estellé, P., & Lugo, L.
Affiliations
  • National Research Council (IT)
  • Laboratoire de génie civil et génie mécanique (FR)
  • Universidade de Vigo (ES)
Corresponding author
Cabaleiro, David
Venue
Nanomaterials
Publisher
MDPI AG
Published
2019-12-19
Volume
10
Issue
1
Pages
19
ISSN
2079-4991 (ISSN-L)
OpenAlex
W2995628132
Cited by
45
References
102
Citations by year
2026: 2 · 2025: 8 · 2024: 5 · 2023: 5 · 2022: 6 · 2021: 11 · 2020: 8
FWCI
3.52
Type
journal article
Language
en
Open access
Locations
  • Nanomaterials (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, other-oa)
  • Investigo repository of University of Vigo (University of Vigo) (submittedVersion, cc-by)
  • Investigo Institutional repository of UVigo (Universidade de Vigo) (submittedVersion, cc-by)
Funders
  • “Ministerio de Economía y Competitividad” (Spain) and FEDER program (ENE2014–55489–C2–2–R, ENE2017–86425–C2–1–R)
  • Xunta de Galicia (GRC ED431C 2016–034)
  • EU COST Action CA15119: Overcoming Barriers to Nanofluids Market Uptake (NANOUPTAKE) (COST-STSM-CA15119–41564, COST-STSM-CA15119–42472)
  • European Union through the European Regional Development Fund (ERDF), the Ministry of Higher Education and Research, the French region of Brittany (and Rennes Métropole)
  • Xunta de Galicia for a postdoctoral fellowship (ED481B-2017/017)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › nanoparticles nucleation surface interactions
Keywords
phase change materials, silver nanoparticles, polyethylene glycol, polyethylene glycol 400, polyvinylpyrrolidone stabilization, thermal energy storage, nanoparticle suspensions, thermal conductivity, dynamic viscosity, heat capacity, density, surface tension, subcooling, Vogel-Fulcher-Tammann equation, nanoparticle volume concentration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.