Cited by 13Electrochemical sensors and biosensorsBiosensors and Analytical DetectionAnalytical Chemistry and Sensors

Use of Biosensors within the Oral Environment for Systemic Health Monitoring—A Systematic Review

Open access
Archer, Natalie, Ladan, Sa’ada, Lancashire, Henry T., Petridis, Haralampos·2024·Oral

Abstract

Scientific advances in biosensor technology are leading to the potential of wearable biosensors for salivary biomarker detection. This review aims to identify the current status of intraoral biosensor technology that can be used to monitor systemic diseases. A total of 11 studies were identified for inclusion, which included nine different devices, including modified mouthguards, retainers, toothbrushes, and dental floss. Out of the 11 studies, 8 studied continuous biomarker monitoring, and the remaining 3 were point-of-care applications. A total of seven biomarkers were studied, six of which investigated the intraoral detection of salivary glucose levels using glucose oxidase enzyme. All the sensors demonstrated excellent sensitivity (minimum R = 0.9928) and selectivity. The study designs were proof of concept, with five studies including in vivo components. We concluded that while there are established links between salivary biomarkers and systemic health, there is a lack of mature intraoral biosensor research. Refinement of biosensor design and data analysis is required to improve patient acceptability by promoting more discrete, real-time, low-cost, and wireless devices. Further research that utilises the biosensor technology in large controlled clinical trials will be required to confirm clinical applicability before intraoral biosensor technology can be integrated into routine health monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/oral4020012

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Urease and glucose oxidase co-immobilized on the sensing interface allow simultaneous acquisition of urea hydrolysis rates and lactic acid production rates by differential potentiometry.

    “In parallel, urease and glucose oxidase are co-immobilized on the sensing interface, allowing simultaneous acquisition of urea hydrolysis rates and lactic acid production rates by differential potentiometry.”

    From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [44]

    The Glucose section identifies glucose oxidase for glucose and lactate oxidase for lactate, not a urease–glucose oxidase pair. The study table (under 5. Conclusions) describes the glucose and lactate sensors as amperometric, not differential-potentiometric. It does not report simultaneous measurement of urea hydrolysis and lactic acid production rates. (LLM, conf=0.84)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Buffer systems, artificial saliva, and selected saliva/serum samples show that PDA-based biosensing platforms can achieve improved biomolecule immobilization, signal transduction, fluorescence/electrochemical/SERS detection, and salivary biomarker analysis.

    “Buffer systems, artificial saliva, and selected saliva/serum samples show improved biomolecule immobilization, signal transduction, fluorescence/electrochemical/SERS detection, and salivary biomarker analysis.”

    From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [44]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • When integrated with disposable microfluidic chambers, the PDA-modified screen-printed carbon electrode platform enables on-site quantification of bacterial load.

    “When integrated with disposable microfluidic chambers, this platform enables on-site quantification of bacterial load.”

    From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [44]

    Section 3.2 describes microfluidic channels in a pacifier used for saliva collection, while the sensor table in Section 5 lists glucose and other chemical biomarkers. Searches for the PDA-modified electrode platform, disposable microfluidic chambers, and bacterial-load quantification found no passage addressing the claimed combination or capability. No page numbers are available in our copy. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • Based on these measurements, the time required for the local pH to reach the critical threshold of 5.5 can be estimated, providing quantitative support for individualized caries risk assessment and personalized fluoride intervention strategies.

    “Based on these measurements, the time required for the local pH to reach the critical threshold of 5.5 can be estimated, thereby providing quantitative support for individualized caries risk assessment and personalized fluoride intervention strategies.44,93,94”

    From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [44]

    Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 37 · Cited by 13

Research works printed but not linked: 36

  1. Freidin, L.; Kulagin, P.; Chishieva, M. Carcinoembryonic antigen in caries and parodontosis. Stomatologiia 1977, 56, 10-12. [PubMed]
  2. Senf, B.; Yeo, W.; Kim, J. Recent Advances in Portable Biosensors for Biomarker Detection in Body Fluids. Biosensors 2020, 10, 127. [CrossRef] [PubMed] · DOI
  3. Kim, J.; Campbell, A.; de Ávila, B.; Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 2019, 37, 389-406. [CrossRef] [PubMed] · DOI · Paper page
  4. Roi, A.; Rusu, L.; Roi, C.; Luca, R.; Boia, S.; Munteanu, R. A New Approach for the Diagnosis of Systemic and Oral Diseases Based on Salivary Biomolecules. Dis. Markers 2019, 2019, 8761860. [CrossRef] [PubMed] · DOI
  5. Kane, S. The effects of oral health on systemic health. Gen. Dent. 2017, 65, 30-34. [PubMed]
  6. Botelho, J.; Mascarenhas, P.; Viana, J.; Proenca, L.; Orlandi, M.; Leira, Y.; Chambrone, L.; Mendes, J.; Machado, V. An umbrella review of the evidence linking oral health and systemic noncommunicable diseases. Nat. Commun. 2022, 13, 7614. [CrossRef] [PubMed] · DOI
  7. Song, Z.; Zhou, S.; Qin, Y.; Xia, X.; Sun, Y.; Hang, G.; Shu, T.; Hu, L.; Zhang, Q. Flexible and Wearable Biosensors for Monitoring Health Conditions. Biosensors 2023, 13, 630. [CrossRef] · DOI
  8. Battelino, T.; Alexander, C.; Amiel, S.; Arreaza-Rubin, G.; Beck, R.W.; Bergenstal, R.M.; Buckingham, B.A.; Carroll, J.; Ceriello, A.; Chow, E.; et al. Continuous glucose monitoring and metrics for clinical trials: An international consensus statement. Lancet Diabetes Endocrinol. 2023, 11, 42-57. [CrossRef] · DOI · Paper page
  9. Graf, H. Telemetry of plaque pH from interdental areas. Helv. Odontol. Acta 1966, 10, 94-101.
  10. Topol, E. A decade of digital medicine innovation. Sci. Transl. Med. 2019, 11, eaaw7610. [CrossRef] [PubMed] · DOI · Paper page
  11. Mani, V.; Beduk, T.; Khashiam, W.; Ceylan, A.; Timur, S.; Wolfbeis, O.; Khaled, N. Electrochemical sensors targeting salivary biomarkers: A comprehensive review. TrAC-Trends Anal. Chem. 2021, 135, 116164. [CrossRef] · DOI
  12. Kim, E.; Joe, E.; Mitchell, R.; Gu, M. Biosensors for healthcare: Current and future perspectives. Trends Biotechnol. 2023, 41, 374-395. [CrossRef] [PubMed] · DOI
  13. Harrison, R.; Jones, B.; Gardener, P.; Lawton, R. Quality assessment with diverse studies (QuADS): An appraisal tool for methodological and reporting quality in systematic reviews of mixed-or multi-method studies. BMC Health Serv. Res. 2021, 21, 144. [CrossRef] · DOI
  14. Sangsawang, R.; Buranachai, C.; Thavarungkul, P.; Kanatharana, P.; Jeerapan, I. Cavitas electrochemical sensors for the direct determination of salivary thiocyanate levels. Microchim. Acta 2021, 188, 415. [CrossRef] · DOI
  15. Pataranutaporn, P.; Jain, A.; Johnson, C.; Shah, P.; Maes, P. Wearable lab on body: Combining sensing of biochemical and digital markers in a wearable device. In Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany, 23-27 July 2019.
  16. Arakawa, T.; Kuroki, Y.; Nitta, H.; Chouhan, P.; Toma, K.; Sawada, S.-I.; Takeuchi, S.; Sekita, T.; Akiyoshi, K.; Minakuchi, S.; et al. Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor. Biosens. Bioelectron. 2015, 84, 106-111. [CrossRef] [PubMed] · DOI · Paper page
  17. Arakawa, T.; Tomoto, K.; Nitta, H.; Toma, K.; Takeuchi, S.; Sekita, T.; Minakuchi, S.; Mitsubayashi, K. A Wearable Cellulose Acetate-Coated Mouthguard Biosensor for in Vivo Salivary Glucose Measurement. Anal. Chem. 2020, 92, 12201-12207. [CrossRef] [PubMed] · DOI
  18. Lee, Y.; Howe, C.; Mishra, S.; Lee, D.S.; Mahmood, M.; Piper, M.; Kim, Y.; Tieu, K.; Byun, H.-S.; Coffey, J.P.; et al. Wireless, intraoral hybrid electronics for real-time quantification of sodium intake toward hypertension management. Proc. Natl. Acad. Sci. USA 2018, 115, 5377-5382. [CrossRef] · DOI · Paper page
  19. Lim, H.-R.; Lee, S.M.; Park, S.; Choi, C.; Kim, H.; Kim, J.; Mahmood, M.; Lee, Y.; Kim, J.-H.; Yeo, W.-H. Smart Bioelectronic Pacifier for Real-Time Continuous Monitoring of Salivary Electrolytes. Biosens. Bioelectron. 2022, 210, 114329. [CrossRef] · DOI
  20. Koukouviti, E.; Soulis, D.; Economou, A.; Kokkinos, C. Wooden Tongue Depressor Multiplex Saliva Biosensor Fabricated via Diode Laser Engraving. Anal. Chem. 2023, 95, 6765-6768. [CrossRef] [PubMed] · DOI
  21. Sha, P.; Luo, X.; Shi, W.; Liu, Y.; Cui, Y. A Smart Dental Floss for Biosensing of Glucose. Electroanalysis 2019, 31, 791-796. [CrossRef] · DOI
  22. Liu, Y.; Yue, W.; Cui, Y. Development of an amperometric biosensor on a toothbrush for glucose. Sens. Actuators Rep. 2023, 5, 100133. [CrossRef] · DOI
  23. Toghill, K.; Compton, R. Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation. Int. J. Electrochem. Sci. 2010, 5, 1246-1301. [CrossRef] · DOI
  24. Haug, C.; Drazen, J. Artificial Intelligence and Machine Learning in Clinical Medicine. N. Engl. J. Med. 2023, 388, 1201-1208. [CrossRef] [PubMed] · DOI · Paper page
  25. Naikoo, G.; Awan, T.; Salim, H.; Arshad, F.; Hassan, I.U.; Pedram, M.Z.; Ahmed, W.; Faruck, H.L.; Aljabali, A.A.A.; Mishra, V.; et al. Fourth-generation glucose sensors composed of copper nanostructures for diabetes management: A critical review. Bioeng. Transl. Med. 2022, 7, e10248. [CrossRef] [PubMed] · DOI
  26. Kaur, S.; Gupta, N.; Malhotra, B. Recent developments in wearable & non-wearable point-of-care biosensors for cortisol detection. Expert Rev. Mol. Diagn. 2023, 23, 217-230. [CrossRef] · DOI
  27. Karachaliou, C.E.; Koukouvinos, G.; Goustouridis, D.; Raptis, I.; Kakabakos, S.; Petrou, P.; Livaniou, E. Cortisol Immunosensors: A Literature Review. Biosensors 2023, 13, 285. [CrossRef] · DOI
  28. Sikorska, D.; Orzechowska, Z.; Rutkowski, R.; Prymas, A.; Mrall-Wechta, M.; Bednarek-Hatli ńska, D.; Roszak, M.; Surdacka, A.; Samborski, W.; Witowski, J. Diagnostic value of salivary CRP and IL-6 in patients undergoing anti-TNF-alpha therapy for rheumatic disease. Inflammopharmacology 2018, 26, 1183-1188. [CrossRef] [PubMed] · DOI
  29. Renda, R. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study. Ren. Fail. 2017, 39, 452-457. [CrossRef] · DOI
  30. Kalasin, S.; Sangnuang, P.; Khownarumit, P.; Tang, M.; Surareungchai, P. Salivary Creatinine Detection Using a Cu(I)/Cu(II) Catalyst Layer of a Supercapacitive Hybrid Sensor: A Wireless IoT Device To Monitor Kidney Diseases for Remote Medical Mobility. Biomater. Sci. Eng. 2020, 6, 5895-5910. [CrossRef] · DOI
  31. Gill, A.; Ghoreishizadeh, S. Advances in nanomaterials integration in CMOS-based electrochemical sensors: A review. IEEE Sens. J. 2023, 23, 4659-4671. [CrossRef] · DOI
  32. Woo, H.; Tolosa, D.; El-Metwally, D.; Viscardi, R. Glucose monitoring in neonates: Need for accurate and non-invasive methods. Arch. Dis. Child. Fetal Neonatal Ed. 2014, 99, F153-F157. [CrossRef] [PubMed] · DOI
  33. McKinlay, C.; Chase, J.; Dickson, J.; Harris, D.; Alsweiler, J.; Harding, J. Continuous glucose monitoring in neonates: A review. Matern. Health Neonatol. Perinatol. 2017, 3, 18. [CrossRef] · DOI
  34. Stieglitz, T. Implantable device fabrication and packaging. In Handbook of Neuroengineering; Spinger Nature: Singapore, 2023; pp. 289-337.
  35. Smith, A.; Li, R.; Tse, Z. Reshaping healthcare with wearable biosensors. Sci. Rep. 2023, 13, 4998.
  36. CrossRef · DOI

Authors
Archer, N., Ladan, S., Lancashire, H. T., & Petridis, H.
Affiliations
  • University College London Hospitals NHS Foundation Trust (GB)
  • University College London (GB)
Venue
Oral
Publisher
MDPI AG
Published
2024-03-30
Volume
4
Issue
2
Pages
148-162
ISSN
2673-6373 (ISSN-L)
OpenAlex
W4393391797
Cited by
13
References
37
Citations by year
2026: 6 · 2025: 7
FWCI
0.30
Type
journal article
Language
en
Open access
Locations
  • Oral (publishedVersion, cc-by)
  • UCL Discovery (University College London) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
salivary biomarkers, wearable biosensors, glucose oxidase, point-of-care testing, continuous biomarker monitoring, toothbrushes, dental floss, wireless devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review