CoChat

Single Microwave Photon Detection with a Trapped Electron

Open access
Cridland, April, Lacy, John, Pinder, Jonathan, Verdú, José · 2016 · Photonics

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index; 19 of the 51 sources its claims cite were checked for support.

Abstract

We investigate theoretically the use of an electron in a Penning trap as a detector of single microwave photons. At the University of Sussex we are developing a chip Penning trap technology, designed to be integrated within quantum circuits. Microwave photons are guided into the trap and interact with the electron’s quantum cyclotron motion. This is an electric dipole transition, where the near field of the microwave radiation induces quantum jumps of the cyclotron harmonic oscillator. The quantum jumps can be monitored using the continuous Stern-Gerlach effect, providing the quantum non demolition signal of the microwave quanta. We calculate the quantum efficiency of photon detection and discuss the main features and technical challenges for the trapped electron as a quantum microwave sensor.

Overview

CoChat Summary

TL;DR

This theoretical paper proposes using a single electron in a planar Penning “geonium chip” as a quantum non-demolition detector of single microwave photons via cyclotron absorption and continuous Stern-Gerlach readout. It derives internal and overall quantum efficiencies, radiative lifetimes, and measurement times, finding that high efficiency requires an open-circuit at the electron and fast phase-based detection of the axial frequency shift.

Key findings

  • The electron’s cyclotron frequency can cover \( \omega_p \in 2\pi \times [2.8, 56] \) GHz for \( B_0 \in [0.1, 2] \) T; a typical \( B_0 = 1 \) T and \( V_r = 1.0 \) V gives \( \omega_p = 2\pi \times 28 \) GHz, \( \omega_z = 2\pi \times 30 \) MHz, and \( \omega_m = 2\pi \times 30 \) kHz.
  • A cyclotron quantum jump \( \Delta n_p = 1 \) produces an axial frequency shift \( \Delta \omega_z = 2\pi \times 30 \) Hz for \( B_2 = 1.5 \) mT/mm² and \( \omega_z^0 = 2\pi \times 30 \) MHz; the detection is QND, with the microwave quantum recoverable during the radiative lifetime \( \tau_s \).
  • Internal quantum efficiency is \( \eta_{\text{internal}} = Y_p/(Y_{\text{CPW}}^L + Y_p) \); an example with \( Y_p \) of a few pS and \( Y_{\text{CPW}}^L \approx 900 \) pS at 4 K gives modest internal quantum efficiencies around 1%–2%, requiring \( Y_{\text{CPW}}^L \to 0 \) for high efficiency.
  • Radiative lifetime \( \tau_s \) is a few to hundred seconds for \( y_0 > 1 \) mm and a few hundred ms for \( y_0 \le 1 \) mm; measurement time \( \tau_m \) can be 8 ms for a 10 Hz jump and 80 µs or less for \( \Delta \omega_z \ge 1 \) kHz. Compared with a Cooper Pair Box, the electron’s transition EDM is about 30 times smaller at ~7 GHz, but the electron is not limited by the \( \eta = 0.5 \) lambda three-level bound and could in principle reach 100% quantum efficiency.

Methods

  • Theoretical/semi-classical analysis of a single electron in a geonium chip planar Penning trap, with cyclotron motion coupled to an itinerant microwave mode via a coplanar-waveguide transmission line.
  • Uses a Hamiltonian of two coupled quantum harmonic oscillators and Fermi’s golden rule to compute photon absorption rates, spontaneous emission rates, characteristic cyclotron admittance, internal quantum efficiency, radiative lifetime, and measurement time from axial phase detection.
  • Describes the planned experimental setup: a 4 K pulse-tube cryostat, a planned adiabatic demagnetisation refrigerator to ~80 mK for cyclotron ground-state initialization, UV loading of electrons, and axial motion detection via induced current in a tuned LC circuit with FFT/phase measurement.

Limitations

  • Stated in the paper: the calculation ignores photon losses along the CPW, restricts to one photon per detection event and near resonance, uses a semi-classical treatment, and assumes an ideal open-circuit at the electron; minimizing losses and realizing the open-circuit are engineering challenges beyond the article’s scope.
  • Stated/evident: the work is theoretical and does not demonstrate a geonium-chip single-microwave-photon detector experimentally; efficiency estimates depend on assumed CPW geometry and dielectric losses, with the example giving only ~1%–2% internal efficiency.
  • Evident from the text: performance depends on empirical \( \sigma(\Delta\phi) \) and achievable magnetic bottle strength; the paper notes that open-circuit imperfections or leaks can substantially reduce efficiency, eventually making it vanish, and N-electron enhancement is left for future work.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/photonics3040059

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

15 Valid · 2 Not valid · 31 Not checked · 79 Own results and interpretations

90 more claims · 4 with their cited sources checked

Create a free account to see all 127 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 13
  • It may state two separate claims as one. 23
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 18

Metadata

Authors
Cridland, A., Lacy, J., Pinder, J., & Verdú, J.
Affiliations
  • Department of Physics and Astronomy, University of Sussex, Falmer BN1 9QH, UK
  • University of Sussex (GB)
Corresponding author
Verdú, José
Venue
Photonics
Publisher
MDPI AG
Published
2016-11-19
Volume
3
Issue
4
Pages
59
ISSN
2304-6732 (ISSN-L)
OpenAlex
W2556536106
Cited by
18
References
37
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3 · 2018: 1 · 2017: 1
FWCI
0.55
Type
journal article
Language
en
Open access
Locations
  • Photonics (publishedVersion, cc-by)
  • Figshare (submittedVersion, cc-by)
  • Sussex Research Online (University of Sussex) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Engineering and Physical Sciences Research Council (EP/N003675/1)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Mechanics and Applications
Keywords
single-photon detection, Penning trap, microwave photon detection, cyclotron motion, electric dipole transitions, quantum jumps, quantum nondemolition detection, quantum efficiency, quantum circuits

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.