Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity
Open accessAbstract
Biodegradable and bioabsorbable polymers have drawn considerable attention because of their mechanical properties that mimic human soft tissue. Poly(l-lactide-co-ε-caprolactone) (PLCL), the copolymer of L-lactic (LA) and ε-caprolactone (CL), has been applied in many tissue engineering and regenerative medicine fields. However, both the synthesis of PLCL and the structure-activity relationship of the copolymer need to be further investigated to allow tuning of different mechanical properties. The synthesis conditions of PLCL were optimized to increase the yield and improve the copolymer properties. The synthetic process was evaluated by while varying the molar ratio of the monomers and polymerization time. The mechanical properties of the copolymer were investigated from the macroscopic and microscopic perspectives. Changes in the polymerization time and feed ratio resulted in the difference in the LA and CL content, which, in turn, caused the PLCL to exhibit different properties. The PLCL obtained with a feed ratio of 1:1 (LA:CL) and a polymerization time of 30 h has the best toughness and elasticity. The developed PLCL may have applications in dynamic mechanical environment, such as vascular tissue engineering.
Overview
CoChat Summary
TL;DR
The paper synthesizes poly(l-lactide-co-ε-caprolactone) (PLCL) by ring-opening polymerization and tunes feed ratio and reaction time to optimize structure, toughness, and elasticity. It reports that PLCL made with a 1:1 LA:CL feed ratio and 30 h polymerization has the best toughness and elasticity among the synthesized samples and better cyclic elastic recovery than a commercial PLCL.
Key findings
- PLCL (1:1-30 h) had the maximum number average molecular weight (Mn = 53.81 × 10³ g/mol) and highest yield (87.34%); the shortest polymerization time (18 h) gave the minimum Mn (20.33 × 10³ g/mol) and lowest yield (76.44%), while 36 h gave Mn = 37.97 × 10³ g/mol.
- Among samples varying only reaction time, PLCL (1:1-30 h) had the highest elastic modulus (8.5 ± 0.6 MPa) and tensile strength (15.1 ± 0.9 MPa); among samples varying feed ratio, PLCL (3:1-24 h) had the highest elastic modulus (46.2 ± 5.9 MPa) and lowest elongation at break (705.1 ± 70.7%).
- In cyclic tensile tests at 250% strain, PLCL (1:1-30 h) had a maximum strain recovery rate of 93.5% and minimum of 88.3%, with only 5.7% reduction in elastic properties after 20 cycles; commercial PLCL (DG) had maximum 79.8%, minimum 69.9%, and 12.4% reduction.
- DSC showed no melting peak for the PLCL copolymers, indicating an amorphous structure; Tg increased then decreased with reaction time, with PLCL (1:1-18 h) lowest at −12.77 °C and PLCL (1:1-30 h) highest at 1.98 °C, while PLCL (3:1-24 h) had the highest Tg (18.51 °C) when varying feed ratio.
Methods
- PLCL copolymers were synthesized by ring-opening polymerization at 150 °C using SnOct₂ catalyst at a 3000:1 comonomers:catalyst molar ratio without initiator, varying polymerization time and LA:CL feed molar ratios; films were prepared by solution casting.
- Characterization included ¹HNMR, FT-IR, GPC, and DSC; mechanical and viscoelastic properties were tested by tensile and cyclic tensile tests (20 cycles, 40 mm/min, 250% strain), rheology at 140 °C and 180 °C, DMA, and AFM, with comparison to a commercial PLCL (DG, LA/CL 50:50, intrinsic viscosity 3.9 dL/g).
- Composition was calculated from ¹HNMR peak integrals; molecular weights and yield from GPC; thermal transitions from DSC; mechanical parameters from tensile curves; and elastic property reduction from Equation (1).
Limitations
- The paper does not state limitations explicitly.
- Evident from the text: PLCL (1:1-18 h) was too sticky to form films by solution casting and could not be tested with the universal tensile testing machine, so mechanical data exclude that synthesis condition.
- Evident from the text: the study reports material characterization and mechanical testing only, with no degradation, biocompatibility, or in vivo performance data, despite discussing tissue-engineering applications; comparison is also limited to one commercial PLCL sample.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
0 Valid · 0 Not valid · 10 Not checked · 45 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The greater was the feed molar ratio of LA to CL, the greater was the content of LA in the PLCL (Table 1).”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.1. Synthesis of PLCL
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When the feed molar ratio of LA:CL was 3:1, the content of LA in PLCL (3:1-24 h) was at its maximum.”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.1. Synthesis of PLCL
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As the reaction time increased over the range of 18 h to 36 h, the characteristic band of C=O shifted to higher wave numbers initially, and then to lower wave numbers (Figure 3d).”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.1. Synthesis of PLCL
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As the number of cycles increased, the strain recovery rate of the materials gradually declined.”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.2. Mechanical Properties
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“indicating that L-LA and ε-CL underwent the ROP successfully.”
- Also stated in: § 3.1. Synthesis of PLCL · plain
“In other words, the ROP of L-LA and ε–CL was carried out and the PLCL copolymers were obtained successfully.”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.1. Synthesis of PLCL
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 3.1. Synthesis of PLCL · plain
21 more claims
Create a free account to see all 55 claims and every source verdict.
- It may state two separate claims as one. 27
- Probably not a substantial claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.1. Synthesis of PLCL
“When the feed molar ratio of LA:CL was 3:1, the content of LA in PLCL (3:1-24 h) was at its maximum.”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.2. Mechanical Properties
“Of all the synthesized PLCL copolymers, PLCL (1:1-30 h) had the highest LA content and the highest average molecular mass (Mn = 53.81 × 103 g/mol), and hence showed the most desirable mechanical properties.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.3. Thermodynamic Properties
“PLCL (1:1-30 h) gave slightly higher G’ and G” curves than PLCL (DG) at this temperature.”
§ Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity > 3. Results and Discussion > 3.3. Thermodynamic Properties
“Furthermore, the storage modulus of PLCL (1:1-30 h) in the low frequency region was lower than PLCL (DG), but it was higher than PLCL (DG) in the high frequency region.”
Citations
Cites
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Synthesis of polycaprolactone: A review
Labet, M., & Thielemans, W. (2009) · Chemical Society Reviews · doi:10.1039/b820162p · Cited by 1,673 · cited 1×
“Poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) polyester materials have been extensively studied [7,8].”
BackgroundA tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314 · cited 1×
“They need to adapt to states of continuous relaxation and contraction to maintain their own performance without mechanical stimulation of the surrounding tissues [14,15].”
BackgroundPoly-lactic acid synthesis for application in biomedical devices — A review
Lasprilla, A. J. R., Martinez, G. A. R., Lunelli, B. H., Jardini, A. L., & Filho, R. M. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.019 · Cited by 1,174 · cited 1×
“Poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) polyester materials have been extensively studied [7,8].”
BackgroundThe in vivo degradation, absorption and excretion of PCL-based implant
Sun, H., Mei, L., Song, C., Cui, X., & Wang, P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.019 · Cited by 976 · cited 1×
“The advantages of their biodegradability, non-toxic degradation products, good biocompatibility, and drug permeability, have attracted widespread attention [9,10].”
BackgroundElastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Biomedical Applications of Biodegradable Polyesters
Manavitehrani, I., Fathi, A., Badr, H., Daly, S., Negahi Shirazi, A., & Dehghani, F. (2016) · Polymers · doi:10.3390/polym8010020 · Cited by 514
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Kharaziha, M., Nikkhah, M., Shin, S.-R., Annabi, N., Masoumi, N., Gaharwar, A. K., Camci-Unal, G., & Khademhosseini, A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.045 · Cited by 313
Fernández, J., Etxeberria, A., & Sarasua, J.-R. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.01.003 · Cited by 217 · cited 2×
“[22] researched the influence of the polymerization temperature and feed ratio on PLCL copolymers and found that changing the polymerization temperature and feed ratio affected the LA content of PLCL copolymers, which, in turn, affected the average sequence length, average relative molecular weight, tensile properties…”
Background
Cited by
Ultra-stretchable and biodegradable elastomers for soft, transient electronics
Han, W. B., Ko, G.-J., Lee, K.-G., Kim, D., Lee, J. H., Yang, S. M., Kim, D.-J., Shin, J.-W., Jang, T.-M., Han, S., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38040-4 · Cited by 159
Bio‐Based Elastomers: Design, Properties, and Biomedical Applications
Liu, Q., Lou, P., Sun, Z., Li, D., Ji, H., Xu, Z., Li, L., Xue, J., Wang, R., Wang, Z., et al. (2025) · Advanced Materials · doi:10.1002/adma.202417193 · Cited by 89
Recent Advances in Electrospun Nanofiber-Based Strategies for Diabetic Wound Healing Application
Li, K., Zhu, Z., Zhai, Y., & Chen, S. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15092285 · Cited by 62
“The high-voltage supply is used to provide a necessary driving force to generate an electric field, and the high-voltage power supply is attached to a polymeric solution as an electrode having a positive charge and adheres to a metallic collector with a negative charge [53].”
BackgroundRajaram, K., Lee, J. H., Youn, J. K., Jang, T., Han, W. B., Yang, S. M., Shin, J., Ko, G., Kim, D., Han, S., et al. (2023) · Advanced Materials · doi:10.1002/adma.202307391 · Cited by 44
Yücer, S., Sarac, B., & Çiftçi, F. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70080 · Cited by 34
Metadata
- Authors
- Zhang, M., Chang, Z., Wang, X., & Li, Q.
- Affiliations
- Zhengzhou University (CN)
- Corresponding author
- Wang, Xiaofeng
- Li, Qian
- Venue
- Polymers
- Publisher
- MDPI AG
- Published
- 2021-04-14
- Volume
- 13
- Issue
- 8
- Pages
- 1270
- ISSN
- 2073-4360 (ISSN-L)
- PMC
- PMC8070679
- OpenAlex
- W3154141492
- Semantic Scholar
- 982ab6cf3dab726be6477cdc2bba5e366a3b1631
- Cited by
- 59
- References
- 38
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 14 · 2023: 8 · 2022: 3 · 2021: 3
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Polymers (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- the International Science & Technology Cooperation Program of China (2015DFA30550)
- the “111” Project of Henan Province (162102210159)
- the key scientific and technological project of Henan Province (172102210489)
- the Key Science & Technology Project for Institutions of Higher Education of Henan Province (19A430003)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- poly(L-lactide-co-ε-caprolactone), copolymer synthesis, monomer feed ratio, polymerization time, mechanical properties, toughness, elasticity, structure-property relationships, biodegradable polymers, vascular tissue engineering, soft tissue scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity. https://app.cochat.ai/papers/10.3390/polym13081270
- The paper
- Zhang, M., Chang, Z., Wang, X., & Li, Q. (2021). Synthesis of Poly(l-lactide-co-ε-caprolactone) Copolymer: Structure, Toughness, and Elasticity. Polymers. https://doi.org/10.3390/polym13081270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.