The DOI matches its Crossref record.
Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
Open accessAbstract
This paper presents a novel method to fabricate temperature sensor arrays by dispensing a graphite-polydimethylsiloxane composite on flexible polyimide films. The fabricated temperature sensor array has 64 sensing cells in a 4 × 4 cm2 area. The sensor array can be used as humanoid artificial skin for sensation system of robots. Interdigitated copper electrodes were patterned on the flexible polyimide substrate for determining the resistivity change of the composites subjected to ambient temperature variations. Polydimethylsiloxane was used as the matrix. Composites of different graphite volume fractions for large dynamic range from 30 ºC to 110 ºC have been investigated. Our experiments showed that graphite powder provided the composite high temperature sensitivity. The fabricated temperature sensor array has been tested. The detected temperature contours are in good agreement with the shapes and magnitudes of different heat sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Technologies for Printing Sensors and Electronics Over Large Flexible Substrates: A Review
Khan, S., Lorenzelli, L., & Dahiya, R. S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2375203 · Cited by 1,225
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
Metadata
- Authors
- Shih, W.-P., Tsao, L.-C., Lee, C.-W., Cheng, M.-Y., Chang, C., Yang, Y.-J., & Fan, K.-C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-04-09
- Volume
- 10
- Issue
- 4
- Pages
- 3597-3610
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1999933062
- Cited by
- 226
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite. https://app.cochat.ai/papers/10.3390/s100403597
- The paper
- Shih, W.-P., Tsao, L.-C., Lee, C.-W., Cheng, M.-Y., Chang, C., Yang, Y.-J., & Fan, K.-C. (2010). Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite. Sensors. https://doi.org/10.3390/s100403597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.