The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Small Molecule Immunosensing Using Surface Plasmon Resonance
Open accessAbstract
Surface plasmon resonance (SPR) biosensors utilize refractive index changes to sensitively detect mass changes at noble metal sensor surface interfaces. As such, they have been extensively applied to immunoassays of large molecules, where their high mass and use of sandwich immunoassay formats can result in excellent sensitivity. Small molecule immunosensing using SPR is more challenging. It requires antibodies or high-mass or noble metal labels to provide the required signal for ultrasensitive assays. Also, it can suffer from steric hindrance between the small antigen and large antibodies. However, new studies are increasingly meeting these and other challenges to offer highly sensitive small molecule immunosensor technologies through careful consideration of sensor interface design and signal enhancement. This review examines the application of SPR transduction technologies to small molecule immunoassays directed to different classes of small molecule antigens, including the steroid hormones, toxins, drugs and explosives residues. Also considered are the matrix effects resulting from measurement in chemically complex samples, the construction of stable sensor surfaces and the development of multiplexed assays capable of detecting several compounds at once. Assay design approaches are discussed and related to the sensitivities obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Population variation in age-related decline in male salivary testosterone.
Ellison, P. T. (2002) · Human Reproduction · doi:10.1093/humrep/17.12.3251 · Cited by 263 · cited 1×
“1–10 ng/mL for salivary cortisol and 29–290 pg/mL for salivary testosterone [35].”
BackgroundStevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
Cited by
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Surface Plasmon Resonance (SPR) Biosensors in Pharmaceutical Analysis
Olaru, A., Bala, C., Jaffrezic-Renault, N., & Aboul-Enein, H. Y. (2015) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.881250 · Cited by 400
High-speed plasmonic modulator in a single metal layer
Ayata, M., Fedoryshyn, Y., Heni, W., Baeuerle, B., Josten, A., Zahner, M., Koch, U., Salamin, Y., Hoessbacher, C., Haffner, C., et al. (2017) · Science · doi:10.1126/science.aan5953 · Cited by 307
Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics
Malon, R. S. P., Sadir, S., Balakrishnan, M., & Córcoles, E. P. (2014) · BioMed Research International · doi:10.1155/2014/962903 · Cited by 260
Metadata
- Authors
- Mitchell, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-08-04
- Volume
- 10
- Issue
- 8
- Pages
- 7323-7346
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2083322644
- Cited by
- 164
- References
- 2
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small Molecule Immunosensing Using Surface Plasmon Resonance. https://app.cochat.ai/papers/10.3390/s100807323
- The paper
- Mitchell, J. (2010). Small Molecule Immunosensing Using Surface Plasmon Resonance. Sensors. https://doi.org/10.3390/s100807323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.