The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Electrochemical Glucose Sensors—Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction
Open accessAbstract
In 1962, Clark and Lyons proposed incorporating the enzyme glucose oxidase in the construction of an electrochemical sensor for glucose in blood plasma. In their application, Clark and Lyons describe an electrode in which a membrane permeable to glucose traps a small volume of solution containing the enzyme adjacent to a pH electrode, and the presence of glucose is detected by the change in the electrode potential that occurs when glucose reacts with the enzyme in this volume of solution. Although described nearly 50 years ago, this seminal development provides the general structure for constructing electrochemical glucose sensors that is still used today. Despite the maturity of the field, new developments that explore solutions to the fundamental limitations of electrochemical glucose sensors continue to emerge. Here we discuss two developments of the last 15 years; confining the enzyme and a redox mediator to a very thin molecular films at electrode surfaces by electrostatic assembly, and the use of electrodes modified by carbon nanotubes (CNTs) to leverage the electrocatalytic effect of the CNTs to reduce the oxidation overpotential of the electrode reaction or for the direct electron transport to the enzyme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Frew, J. E., & Hill, H. A. O. (1987) · Analytical Chemistry · doi:10.1021/ac00142a001 · Cited by 252
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
Putzbach, W., & Ronkainen, N. (2013) · Sensors · doi:10.3390/s130404811 · Cited by 502
Metadata
- Authors
- Harper, A., & Anderson, M. R.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-09-02
- Volume
- 10
- Issue
- 9
- Pages
- 8248-8274
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1976820636
- Cited by
- 172
- References
- 3
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Glucose Sensors—Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction. https://app.cochat.ai/papers/10.3390/s100908248
- The paper
- Harper, A., & Anderson, M. R. (2010). Electrochemical Glucose Sensors—Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction. Sensors. https://doi.org/10.3390/s100908248
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.