Upper Limb Portable Motion Analysis System Based on Inertial Technology for Neurorehabilitation Purposes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Here an inertial sensor-based monitoring system for measuring and analyzing upper limb movements is presented. The final goal is the integration of this motion-tracking device within a portable rehabilitation system for brain injury patients. A set of four inertial sensors mounted on a special garment worn by the patient provides the quaternions representing the patient upper limb’s orientation in space. A kinematic model is built to estimate 3D upper limb motion for accurate therapeutic evaluation. The human upper limb is represented as a kinematic chain of rigid bodies with three joints and six degrees of freedom. Validation of the system has been performed by co-registration of movements with a commercial optoelectronic tracking system. Successful results are shown that exhibit a high correlation among signals provided by both devices and obtained at the Institut Guttmann Neurorehabilitation Hospital.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Inertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106
Cited by
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
“99, showing fair to good validity [28,32,33,35,37,43].”
BackgroundWearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Bouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
“reported to be to align coordinate systems [39, 56] and account for inaccuracies in the orientation of wearable sensor chip relative to its case/packaging [62].”
Background
Metadata
- Authors
- Pérez, R., Costa, Ú., Torrent, M., Solana, J., Opisso, E., Cáceres, C., Tormos, J. M., Medina, J., & Gómez, E. J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-12-02
- Volume
- 10
- Issue
- 12
- Pages
- 10733-10751
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2078310649
- Cited by
- 97
- References
- 2
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.