The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey
Open accessAbstract
Appliance Load Monitoring (ALM) is essential for energy management solutions, allowing them to obtain appliance-specific energy consumption statistics that can further be used to devise load scheduling strategies for optimal energy utilization. Fine-grained energy monitoring can be achieved by deploying smart power outlets on every device of interest; however it incurs extra hardware cost and installation complexity. Non-Intrusive Load Monitoring (NILM) is an attractive method for energy disaggregation, as it can discern devices from the aggregated data acquired from a single point of measurement. This paper provides a comprehensive overview of NILM system and its associated methods and techniques used for disaggregated energy sensing. We review the state-of-the art load signatures and disaggregation algorithms used for appliance recognition and highlight challenges and future research directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonintrusive appliance load monitoring
Hart, G. W. (1992) · Proceedings of the IEEE · doi:10.1109/5.192069 · Cited by 3,165
Dey, A. K., Abowd, G. D., & Salber, D. (2001) · Human–Computer Interaction · doi:10.1207/s15327051hci16234_02 · Cited by 2,951
Nonintrusive appliance load monitoring: Review and outlook
Zeifman, M., & Roth, K. (2011) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2011.5735484 · Cited by 811
Unsupervised Disaggregation of Low Frequency Power Measurements
Kim, H., Marwah, M., Arlitt, M. F., Lyon, G., & Han, J. (2011) · SIAM International Conference on Data Mining · doi:10.1137/1.9781611972818.64 · Cited by 737
Is disaggregation the holy grail of energy efficiency? The case of electricity
Carrie Armel, K., Gupta, A., Shrimali, G., & Albert, A. (2013) · Energy Policy · doi:10.1016/j.enpol.2012.08.062 · Cited by 595
Laughman, C., Lee, K., Cox, R., Shaw, S., Leeb, S., Norford, L., & Armstrong, P. (2003) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2003.1192027 · Cited by 572
Approximate Inference in Additive Factorial HMMs with Application to Energy Disaggregation
Kolter, J. Z., & Jaakkola, T. (2018) · DSpace@MIT (Massachusetts Institute of Technology) · doi:10.1184/r1/6603563 · Cited by 453
Load Signature Study—Part I: Basic Concept, Structure, and Methodology
Liang, J., Ng, S. K. K., Kendall, G., & Cheng, J. W. M. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2033799 · Cited by 453
Neural-Network-Based Signature Recognition for Harmonic Source Identification
Srinivasan, D., Ng, W. S., & Liew, A. C. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.852370 · Cited by 453
Gupta, S., Reynolds, M. S., & Patel, S. N. (2010) · Proceedings of the 12th ACM international conference on Ubiquitous computing · doi:10.1145/1864349.1864375 · Cited by 422
Energy Disaggregation via Discriminative Sparse Coding
Kolter, J. Z., Batra, S., & Ng, A. Y. (2010) · neural information processing systems · Cited by 412
Patel, S., Robertson, T. M., Kientz, J. A., Reynolds, M. S., & Abowd, G. D. (2007) · Ubiquitous Computing · doi:10.5555/1771592.1771608 · Cited by 331
A Novel Method to Construct Taxonomy Electrical Appliances Based on Load Signaturesof
Lam, H., Fung, G., & Lee, W. (2007) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2007.381742 · Cited by 324
Norford, L. K., & Leeb, S. B. (1996) · Energy and Buildings · doi:10.1016/0378-7788(95)00958-2 · Cited by 323
Transient event detection in spectral envelope estimates for nonintrusive load monitoring
Leeb, S. B., Shaw, S. R., & Kirtley, J. L. (1995) · IEEE Transactions on Power Delivery · doi:10.1109/61.400897 · Cited by 311
Inferring Personal Information from Demand-Response Systems
Lisovich, M. A., Mulligan, D. K., & Wicker, S. B. (2010) · IEEE Security & Privacy Magazine · doi:10.1109/msp.2010.40 · Cited by 298
Tiny web services: design and implementation of interoperable and evolvable sensor networks
Priyantha, N. B., Kansal, A., Goraczko, M., & Zhao, F. (2008) · Proceedings of the 6th ACM conference on Embedded network sensor systems · doi:10.1145/1460412.1460438 · Cited by 258
Nonintrusive Load Monitoring and Diagnostics in Power Systems
Shaw, S. R., Leeb, S. B., Norford, L. K., & Cox, R. W. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.917179 · Cited by 256
Farinaccio, L., & Zmeureanu, R. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(99)00007-9 · Cited by 240
Event detection for Non Intrusive load monitoring
Anderson, K. D., Berges, M. E., Ocneanu, A., Benitez, D., & Moura, J. M. F. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6389367 · Cited by 236
Domestic energy fact file 2003
Shorrock, L. D., & Utley, J. (2003) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 224
Nonintrusive monitoring of electric loads
Drenker, S., & Kader, A. (1999) · IEEE Computer Applications in Power · doi:10.1109/67.795138 · Cited by 187
Load Signature Study—Part II: Disaggregation Framework, Simulation, and Applications
Liang, J., Ng, S. K. K., Kendall, G., & Cheng, J. W. M. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2033800 · Cited by 184
Enhancing Electricity Audits in Residential Buildings with Nonintrusive Load Monitoring
Berges, M. E., Goldman, E., Matthews, H. S., & Soibelman, L. (2010) · Journal of Industrial Ecology · doi:10.1111/j.1530-9290.2010.00280.x · Cited by 179
Marceau, M. L., & Zmeureanu, R. (2000) · Energy Conversion and Management · doi:10.1016/s0196-8904(99)00173-9 · Cited by 176
User-Centered Nonintrusive Electricity Load Monitoring for Residential Buildings
Berges, M. E., Goldman, E., Matthews, H. S., Soibelman, L., & Anderson, K. (2011) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000108 · Cited by 152
Genetic algorithm for pattern detection in NIALM systems
Baranski, M., & Voss, J. (2005) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2004.1400878 · Cited by 152
Disaggregation of home energy display data using probabilistic approach
Zeifman, M. (2012) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2012.6170051 · Cited by 149
A hidden Markov model based procedure for identifying household electric loads
Zia, T., Bruckner, D., & Zaidi, A. A. (2011) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2011.6119826 · Cited by 132
Learning Systems for Electric Consumption of Buildings
Berges, M. E., Goldman, E., Matthews, H. S., & Soibelman, L. (2009) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/41052(346)1 · Cited by 131
Kato, T., Cho, H. S., Lee, D., Toyomura, T., & Yamazaki, T. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02868-7_19 · Cited by 110
Disaggregation of home energy display data using probabilistic approach
Zeifman, M., & Roth, K. W. (2012) · International Conference on Consumer Electronics · doi:10.1109/icce.2012.6162005 · Cited by 109
Multi-appliance recognition system with hybrid SVM/GMM classifier in ubiquitous smart home
Lai, Y.-H., Lai, C., Huang, Y., & Chao, H. (2012) · Information Sciences · doi:10.1016/j.ins.2012.10.002 · Cited by 99
Modeling and Estimating Current Harmonics of Variable Electronic Loads
Wichakool, W., Avestruz, A.-T., Cox, R. W., & Leeb, S. B. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029231 · Cited by 98
Exploration on Load Signatures
Lee, W. K., Fung, G. S. K., Lam, H.-Y., Chan, F. H. Y., & Lucente, M. E. (2004) · Cited by 86
Contactless sensing of appliance state transitions through variations in electromagnetic fields
Rowe, A., Berges, M. E., & Rajkumar, R. (2010) · doi:10.1145/1878431.1878437 · Cited by 85
Using a rule-based algorithm to disaggregate end-use load profiles from premise-level data
Powers, J. T., Margossian, B., & Smith, B. A. (1991) · IEEE Computer Applications in Power · doi:10.1109/67.75875 · Cited by 71
Look Back before Leaping Forward: Four Decades of Domestic Energy Inquiry
Hazas, M., Friday, A., & Scott, J. (2010) · IEEE Pervasive Computing · doi:10.1109/mprv.2010.89 · Cited by 71
Cox, R. W., Leeb, S. B., Shaw, S. R., & Norford, L. K. (2006) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2006.1620777 · Cited by 66
Non-intrusive appliance load monitoring based on an optical sensor
Baranski, M., & Voss, J. (2004) · doi:10.1109/ptc.2003.1304732 · Cited by 64
S-TREE: self-organizing trees for data clustering and online vector quantization
Campos, M. M., & Carpenter, G. A. (2001) · Neural Networks · doi:10.1016/s0893-6080(01)00020-x · Cited by 55
A time-frequency approach for event detection in non-intrusive load monitoring
Jin, Y., Tebekaemi, E., Berges, M. E., & Soibelman, L. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.884385 · Cited by 53
Robust adaptive event detection in non-intrusive load monitoring for energy aware smart facilities
Jin, Y., Tebekaemi, E., Berges, M. E., & Soibelman, L. (2011) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2011.5947314 · Cited by 49
Nonintrusive appliance load monitoring based on integer programming
Inagaki, S., Egami, T., Suzuki, T., Nakamura, H., & Ito, K. (2010) · Electrical Engineering in Japan · doi:10.1002/eej.21040 · Cited by 41
Towards automated appliance recognition using an EMF sensor in NILM platforms
Giri, S., Berges, M. E., & Rowe, A. (2013) · Advanced Engineering Informatics · doi:10.1016/j.aei.2013.03.004 · Cited by 37
Cited by
A review on buildings energy information: Trends, end-uses, fuels and drivers
González-Torres, M., Pérez-Lombard, L., Coronel, J. F., Maestre, I. R., & Yan, D. (2022) · Energy Reports · doi:10.1016/j.egyr.2021.11.280 · Cited by 1,036
Antonopoulos, I., Robu, V., Couraud, B., Kirli, D., Norbu, S., Kiprakis, A., Flynn, D., Elizondo-Gonzalez, S., & Wattam, S. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109899 · Cited by 656
Measures to improve energy demand flexibility in buildings for demand response (DR): A review
Chen, Y., Xu, P., Gu, J., Schmidt, F., & Li, W. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.003 · Cited by 372
Transfer Learning for Non-Intrusive Load Monitoring
D'Incecco, M., Squartini, S., & Zhong, M. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2938068 · Cited by 330
“toring is a research topic which investigates to retrieve the real-time energy consumption of each appliance within household buildings [3], [4].”
BackgroundAn Empirical Investigation of V-I Trajectory Based Load Signatures for Non-Intrusive Load Monitoring
Hassan, T., Javed, F., & Arshad, N. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2271282 · Cited by 322
Metadata
- Authors
- Zoha, A., Gluhak, A., Imran, M., & Rajasegarar, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2012-12-06
- Volume
- 12
- Issue
- 12
- Pages
- 16838-16866
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1994042232
- Cited by
- 954
- References
- 45
- FWCI
- 25.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.