Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Cited by
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Dagdeviren, C., Joe, P., Tuzman, O. L., Park, K.-I., Lee, K. J., Shi, Y., Huang, Y., & Rogers, J. A. (2016) · Extreme Mechanics Letters · doi:10.1016/j.eml.2016.05.015 · Cited by 499
A review of flexible perovskite oxide ferroelectric films and their application
Gao, W., Zhu, Y., Wang, Y., Yuan, G., & Liu, J.-M. (2020) · Journal of Materiomics · doi:10.1016/j.jmat.2019.11.001 · Cited by 254
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151
Metadata
- Authors
- Tseng, H.-J., Tian, W.-C., & Wu, W.-J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-04-25
- Volume
- 13
- Issue
- 5
- Pages
- 5478-5492
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2032983828
- Cited by
- 70
- References
- 1
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.