Three Dimensional Gait Analysis Using Wearable Acceleration and Gyro Sensors Based on Quaternion Calculations
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This paper proposes a method for three dimensional gait analysis using wearable sensors and quaternion calculations. Seven sensor units consisting of a tri-axial acceleration and gyro sensors, were fixed to the lower limbs. The acceleration and angular velocity data of each sensor unit were measured during level walking. The initial orientations of the sensor units were estimated using acceleration data during upright standing position and the angular displacements were estimated afterwards using angular velocity data during gait. Here, an algorithm based on quaternion calculation was implemented for orientation estimation of the sensor units. The orientations of the sensor units were converted to the orientations of the body segments by a rotation matrix obtained from a calibration trial. Body segment orientations were then used for constructing a three dimensional wire frame animation of the volunteers during the gait. Gait analysis was conducted on five volunteers, and results were compared with those from a camera-based motion analysis system. Comparisons were made for the joint trajectory in the horizontal and sagittal plane. The average RMSE and correlation coefficient (CC) were 10.14 deg and 0.98, 7.88 deg and 0.97, 9.75 deg and 0.78 for the hip, knee and ankle flexion angles, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Rotations, quaternions, and double groups
Altmann, S. L. (1986) · CERN Document Server (European Organization for Nuclear Research) · Cited by 945
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911 · cited 1×
“An alternative is to use acceleration or angular velocity data measured from small inertial sensors attached directly to the body [1–4].”
MethodFoot Trajectory in Human Gait: A Precise and Multifactorial Motor Control Task
Winter, D. A. (1992) · Physical Therapy · doi:10.1093/ptj/72.1.45 · Cited by 505 · cited 1×
“These results seem to concur with previous findings, where it was reported that the foot angular velocity was higher than those of the shank or the thigh [22,23].”
ResultDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 1×
“An alternative is to use acceleration or angular velocity data measured from small inertial sensors attached directly to the body [1–4].”
MethodDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“An alternative is to use acceleration or angular velocity data measured from small inertial sensors attached directly to the body [1–4].”
MethodA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 1×
“Tong and Granat calculated lower limb body segments’ orientations by integrating measured angular velocity from gyro sensors strapped to the thigh and shank [6].”
BackgroundValidation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415 · cited 1×
“[21], the knee joint center was assumed to be the midpoint between the lateral and medial epicondyles, and the ankle joint center was assumed to be the midpoint between the lateral and medial ankle anatomical landmarks.”
BackgroundWindolf, M., Götzen, N., & Morlock, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.024 · Cited by 415 · cited 1×
“Even though Vicon motion analysis systems are considered the gold standard for 3-D motion tracking, there are many papers reporting its accuracy errors [28,29].”
BackgroundAmbulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356 · cited 1×
“In addition, acceleration gyro and magnetic sensors proved useful in calculating the kinematics of the arm [15,16].”
Method
Cited by
Polydimethylsiloxane (PDMS)-Based Flexible Resistive Strain Sensors for Wearable Applications
Chen, J., Zheng, J., Gao, Q., Zhang, J., Zhang, J., Omisore, O., Wang, L., & Li, H. (2018) · Applied Sciences · doi:10.3390/app8030345 · Cited by 332
Methodological aspects of EEG and body dynamics measurements during motion
Reis, P. M. R., Hebenstreit, F., Gabsteiger, F., von Tscharner, V., & Lochmann, M. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00156 · Cited by 159
“The combination of these body sensors can then be fused to estimate joint angles (Cooper et al., 2009; Sabatini, 2011; Tadano et al., 2013).”
Optimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Thigh Lateral mid-thigh 3 * Laudanski 2013 [19], Kong 2013 [16] Lateral near knee 2 Vargas-Valencia 2016 [26], Guo 2012 [28] Anterior near knee 2 Tadano 2013 [30], Lau 2008 [33]”
BackgroundDrift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
Takeda, R., Lisco, G., Fujisawa, T., Gastaldi, L., Tohyama, H., & Tadano, S. (2014) · Sensors · doi:10.3390/s141223230 · Cited by 84
Self-citation
Metadata
- Authors
- Tadano, S., Takeda, R., & Miyagawa, H.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-07-19
- Volume
- 13
- Issue
- 7
- Pages
- 9321-9343
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2104106974
- Cited by
- 171
- References
- 28
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.