A Wearable Inertial Measurement Unit for Long-Term Monitoring in the Dependency Care Area
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Human movement analysis is a field of wide interest since it enables the assessment of a large variety of variables related to quality of life. Human movement can be accurately evaluated through Inertial Measurement Units (IMU), which are wearable and comfortable devices with long battery life. The IMU’s movement signals might be, on the one hand, stored in a digital support, in which an analysis is performed a posteriori. On the other hand, the signal analysis might take place in the same IMU at the same time as the signal acquisition through online classifiers. The new sensor system presented in this paper is designed for both collecting movement signals and analyzing them in real-time. This system is a flexible platform useful for collecting data via a triaxial accelerometer, a gyroscope and a magnetometer, with the possibility to incorporate other information sources in real-time. A µSD card can store all inertial data and a Bluetooth module is able to send information to other external devices and receive data from other sources. The system presented is being used in the real-time detection and analysis of Parkinson’s disease symptoms, in gait analysis, and in a fall detection system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“IMUs have been employed for human movement analysis with several possible goals, such as measuring energy expenditure [17] or performance variables in sports [18].”
MethodA Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“In the studies performed in CETpD, the sensor is used at waist, which is considered the most suitable location for measuring human movement according to some authors [14,15,58].”
MethodMonitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“For example, within the field of studying Parkinson’s disease (PD), decision trees [19], linear classifiers [20] or Support Vector Machines (SVM) [21–23] have been used to determine specific symptoms of the disease.”
BackgroundDirect measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416 · cited 1×
“For example, within the field of studying Parkinson’s disease (PD), decision trees [19], linear classifiers [20] or Support Vector Machines (SVM) [21–23] have been used to determine specific symptoms of the disease.”
BackgroundRochester, L., Nieuwboer, A., Baker, K., Hetherington, V., Willems, A.-M., Chavret, F., Kwakkel, G., Van Wegen, E., Lim, I., & Jones, D. (2007) · Journal of Neural Transmission · doi:10.1007/s00702-007-0756-y · Cited by 150 · cited 1×
“The Vitaport Activity Monitor (Temec, Kerkrade, The Netherlands) is another datalogger IMU which has been used to study and analyze Parkinson’s Disease patients symptoms [46–48].”
Method
Cited by
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
Hulleck, A. A., Menoth Mohan, D., Abdallah, N., El Rich, M., & Khalaf, K. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.901331 · Cited by 281
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
“Acceleration signals were captured while patients executed the described protocol with the 9x2 Inertial Measurement Unit (IMU), a small (77x37x21mm(3)) and light (78g with battery) wearable inertial system (Fig 2) which was located at the left side of the waist [64].”
MethodSelf-citationCamps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez-López, C., Moreno Arostegui, J. M., Cabestany, J., Català, A., Alcaine, S., Mestre, B., et al. (2018) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.10.017 · Cited by 224
Using Portable Transducers to Measure Tremor Severity
Elble, R. J., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.320 · Cited by 95
Metadata
- Authors
- Rodríguez-Martín, D., Pérez-López, C., Samà, A., Cabestany, J., & Català, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-10-18
- Volume
- 13
- Issue
- 10
- Pages
- 14079-14104
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2079985134
- Cited by
- 85
- References
- 6
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.