Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Open accessThe DOI matches its Crossref record; 89 of the 90 references it cites were found in a registry or an index.
Abstract
On-line sensors for the detection of crucial process parameters are desirable for the monitoring, control and automation of processes in the biotechnology, food and pharma industry. Fluorescence spectroscopy as a highly developed and non-invasive technique that enables the on-line measurements of substrate and product concentrations or the identification of characteristic process states. During a cultivation process significant changes occur in the fluorescence spectra. By means of chemometric modeling, prediction models can be calculated and applied for process supervision and control to provide increased quality and the productivity of bioprocesses. A range of applications for different microorganisms and analytes has been proposed during the last years. This contribution provides an overview of different analysis methods for the measured fluorescence spectra and the model-building chemometric methods used for various microbial cultivations. Most of these processes are observed using the BioView® Sensor, thanks to its robustness and insensitivity to adverse process conditions. Beyond that, the PLS-method is the most frequently used chemometric method for the calculation of process models and prediction of process variables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In biotechnology, fluorescence measurements are commonly used for the detection of biological molecules such as proteins, amino acids (e.g., tryptophan, tyrosine, and phenylalanine), vitamins, and cofactors, e.g., FAD and NADH (Faassen and Hitzmann 2015).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Faassen and Hitzmann 2015
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The lower detection of NIR, for example, compared with FTIR, makes the latter a desirable option for quantification at sub g/L concentrations [100] often observed in microalgal bioreactions.”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [100]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728 · cited 1×
“Different algorithms are implemented to handle cultivation data with neural networks [85,86], for example using feed-forward neural networks (FFNN) [21] with back-propagation neural networks (BPNN) [31].”
MethodPrinciples of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Wold, S., Esbensen, K., & Geladi, P. (1987) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(87)80084-9 · Cited by 11,606
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084 · cited 7×
“PLS enables the identification of the factors that not only show the largest amount of variance, but also allows a linear correlation between the fluorescence spectra and process variables via the covariance of the two data sets.”
MethodInfluentialMultilayer feedforward networks are universal approximators
HornikK., StinchcombeM., & WhiteH. (1989) · Neural Networks · doi:10.5555/70405.70408 · Cited by 9,081
Kohonen, T. (1990) · Proceedings of the IEEE · doi:10.1109/5.58325 · Cited by 8,414
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992 · cited 8×
“PLS enables the identification of the factors that not only show the largest amount of variance, but also allows a linear correlation between the fluorescence spectra and process variables via the covariance of the two data sets.”
MethodInfluentialTsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Research works printed but not linked: 1
- Moretto J. Smelko J.P. Cuellar M. Berry B. Doane A. Ryll T. Wiltberger K. Process Raman Spectroscopy for In-Line CHO Cell Culture Monitoring Am. Pharm. Rev. 2011 14 18 25
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
“For more than 30 years, fluorescence spectroscopy has been used to monitor biotechnological processes [76].”
BackgroundSurvey on Methods for Investigating Protein Functionality and Related Molecular Characteristics
Zhang, Y., Sharan, S., Rinnan, Å., & Orlien, V. (2021) · Foods · doi:10.3390/foods10112848 · Cited by 119
“The energy of emission is smaller than that absorbed, and the difference between them is named the Stokes shift [86,87].”
BackgroundDevelopment of Novel Bioreactor Control Systems Based on Smart Sensors and Actuators
Wang, B., Wang, Z., Chen, T., & Zhao, X. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00007 · Cited by 107
“…bioreactors for wastewater treatment, classic tank bioreactors used in the fermentation industry, and the recently developed inexpensive single-use bioreactors for the small-scale production of high-value biological pharmaceuticals (Zhuo et al., 2018; Fang et al., 2019; Metze et al., 2019).”
BackgroundThe physical stability of plant-based drinks and the analysis methods thereof
Patra, T., Rinnan, Å., & Olsen, K. (2021) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2021.106770 · Cited by 95
“Hence, the fluorescence signal is sensitive to its local environment (Christensen, Nørgaard, Bro, & Engelsen, 2006; Faassen & Hitzmann, 2015; Lakowicz, 2006).”
BackgroundDevelopment of generic raman models for a GS‐KO TM CHO platform process
Webster, T. A., Hadley, B. C., Hilliard, W., Jaques, C., & Mason, C. (2018) · Biotechnology Progress · doi:10.1002/btpr.2633 · Cited by 77
“, glucose).(21) Despite this Teixeira et al.”
Jian, X., Guo, X., Wang, J., Tan, Z. L., Xing, X., Wang, L., & Zhang, C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27327 · Cited by 80
“…control of cultivation parameters (e.g., temperature, pH and nutrient concentrations) and methods of detection (e.g., optical density, fluorescence intensity, pH and dissolved oxygen) has been achieved by implementing novel analytical technologies (Faassen & Hitzmann, 2015; Marose et al., 1999).”
On-Line Monitoring of Biological Parameters in Microalgal Bioprocesses Using Optical Methods
Havlik, I., Beutel, S., Scheper, T., & Reardon, K. F. (2022) · Energies · doi:10.3390/en15030875 · Cited by 73
“As in the previous case, on-line turbidity data calibrated with DWC with a 5 s sampling rate and off-line glucose data in 1 h intervals were used as process inputs for the UKF estimating the lipid concentrations, and all three variables were fed into the MPC to calculate process control inputs…”
Kornecki, M., & Strube, J. (2018) · Bioengineering · doi:10.3390/bioengineering5010025 · Cited by 61
“Techniques such as Principal Component Analysis (PCA), Principal Components Regression (PCR), and Partial Least Squares Regression (PLS) are used in order to describe the correlation between responses and factors, especially in spectral data [4,9,14,15].”
MethodFluorescence spectroscopy and imaging instruments for food quality evaluation
Sikorska, E., Khmelinskii, I. V., & Sikorski, M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814217-2.00019-6 · Cited by 56
The ecology of wine fermentation: a model for the study of complex microbial ecosystems
Conacher, C. G., Luyt, N. A., Naidoo-Blassoples, R. K., Rossouw, D., Setati, M. E., & Bauer, F. F. (2021) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-021-11270-6 · Cited by 51
“…white must non-Saccharomyces submerged into 1.2 l white must S. cerevisiae; cut-off 12-14 kDa Petitgonnet et al. 2019 spectroscopy, including vibrational spectroscopy or fluorescence spectroscopy, coupled to chemometric analyses (Lourenço et al. 2012; Faassen and Hitzmann 2015; Wang et al. 2020).”
MethodInfluentialNakar, A., Schmilovitch, Z., Vaizel‐Ohayon, D., Kroupitski, Y., Borisover, M. D., & Sela, S. (2019) · Water Research · doi:10.1016/j.watres.2019.115197 · Cited by 51
Recent developments in fermentation technology: toward the next revolution in food production
Terefe, N. S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821292-9.00026-1 · Cited by 50
Software sensors in the monitoring of microalgae cultivations
Porras Reyes, L., Havlik, I., & Beutel, S. (2024) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-023-09679-8 · Cited by 48
“In biotechnology, fluorescence measurements are commonly used for the detection of biological molecules such as proteins, amino acids (e.g., tryptophan, tyrosine, and phenylalanine), vitamins, and cofactors, e.g., FAD and NADH (Faassen and Hitzmann 2015).”
Rowland‐Jones, R. C., van den Berg, F., Racher, A. J., Martin, E. B., & Jaques, C. (2017) · Biotechnology Progress · doi:10.1002/btpr.2459 · Cited by 48
Measurement Techniques to Resolve and Control Population Dynamics of Mixed-Culture Processes
Schlembach, I., Grünberger, A., Rosenbaum, M. A., & Regestein, L. (2021) · Trends in biotechnology · doi:10.1016/j.tibtech.2021.01.006 · Cited by 49
“To condense and dissect the resulting large amount of data provided by full spectrum scans, mathematical tools such as partial least square (PLS) regression and principal component analysis (PCA) are essential to gain relevant information output [84,85].”
MethodComparison of Modeling Methods for DoE‐Based Holistic Upstream Process Characterization
Bayer, B., von Stosch, M., Striedner, G., & Duerkop, M. (2020) · Biotechnology Journal · doi:10.1002/biot.201900551 · Cited by 51
Practical monitoring technologies for cells and substrates in biomanufacturing
Reardon, K. F. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.08.006 · Cited by 56
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“state, the emitted photon is of lower energy, causing a redshift in the emitted light [14,47].”
BackgroundInfluentialMarkana, A., Padhiyar, N. U., & Moudgalya, K. M. (2018) · Process Safety and Environmental Protection · doi:10.1016/j.cherd.2018.05.032 · Cited by 41
Fluorescence Spectroscopy for the Monitoring of Food Processes
Ahmad, M. H., Sahar, A., & Hitzmann, B. (2017) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2017_11 · Cited by 40
Self-citationGraf, A., Claßen, J., Solle, D., Hitzmann, B., Rebner, K., & Hoehse, M. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201800149 · Cited by 39
“Fluorescence spectroscopy is well established in analytical applications, and for more than thirty years, it has been investigated for its bioprocess monitoring capabilities [3,4].”
BackgroundMethodSelf-citationBioprocess Technologies that Preserve the Quality of iPSCs
Polanco, A., Kuang, B., & Yoon, S. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.03.006 · Cited by 42
Podevin, M., Fotidis, I. A., & Angelidaki, I. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1398132 · Cited by 34
“453 Furthermore, spectroscopic techniques such as fluorescence [107] and NIR spectroscopy 454 [116] have been suggested to refine these soft sensor algorithms.”
MethodZimmerleiter, R., Kager, J., Nikzad‐Langerodi, R., Berezhinskiy, V., Westad, F., Herwig, C., & Brandstetter, M. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02227-w · Cited by 34
Carvalho, D. V. C., Ranzan, L., Trierweiler, L. F., & Trierweiler, J. O. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.127142 · Cited by 33
Klanian, M. G., Bouchot, G. G., Delgadillo-Díaz, M., Aranda, J., & Sánchez-Solís, M. J. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-021-13148-6 · Cited by 33
Claßen, J., Graf, A., Aupert, F., Solle, D., Hoehse, M., & Scheper, T. H. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201800146 · Cited by 32
“In most applications, the BioView instrument (Delta, Denmark) has been used to obtain spectral data [13].”
MethodHassoun, A. (2021) · Photochem · doi:10.3390/photochem1020015 · Cited by 32
Ahmad, M. H., Nache, M., Waffenschmidt, S., & Hitzmann, B. (2016) · Food Control · doi:10.1016/j.foodcont.2016.01.029 · Cited by 32
Self-citationLieutaud, C., Assaf, A., Gonçalves, O., Wielgosz‐Collin, G., & Thouand, G. (2019) · Algal Research · doi:10.1016/j.algal.2019.101595 · Cited by 33
Application of convolutional neural networks for prediction of disinfection by-products
Peleato, N. M. (2022) · Scientific Reports · doi:10.1038/s41598-021-03881-w · Cited by 34
“The use of fluorescence spectra for improved water quality monitoring(1) and as a process analytical 25 technology for bioprocesses, food, and pharmaceutical production, has become increasingly popular.(2,3) 26 Fluorescence signatures are highly dependent on molecular structure, size, and environmental conditions, 27…”
BackgroundBayer, B., von Stosch, M., Melcher, M., Duerkop, M., & Striedner, G. (2020) · Engineering in Life Sciences · doi:10.1002/elsc.201900076 · Cited by 27
“Fluorescence spectroscopy is based on determining the specific excitation and emission wavelengths of a compound in order to identify it qualitatively and quantitatively, in the range of the measured 2D-fluorescence spectrum [11,12].”
BackgroundDestro, F., Wu, W., Srinivasan, P., Joseph, J., Bal, V., Neufeld, C. I., Wolfrum, J. M., Manalis, S. R., Sinskey, A. J., Springs, S. L., et al. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108433 · Cited by 32
“Recently, soft sensors have been implemented to estimate the cell and metabolite concentrations in mammalian cell cultures from fluorescence and Raman spectroscopy (Abu-Absi et al., 2011; Berry et al., 2015; Faassen and Hitzmann, 2015; Maruthamuthu et al., 2020).”
BackgroundFinger, M., Sentek, F., Hartmann, L., Palacio‐Barrera, A. M., Schlembach, I., Rosenbaum, M. A., & Büchs, J. (2022) · Engineering in Life Sciences · doi:10.1002/elsc.202100151 · Cited by 25
“Autofluorescence of flavins was monitored at λex/λem 483/520 nm as an indicator for biomass and as a more precise signal compared to the scattered light signal [25, 26].”
MethodOn-line monitoring of process parameters during fermentation
Gargalo, C. L., López, P. C., Hasanzadeh, A., Udugama, I. A., & Gernaey, K. V. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91167-2.00003-4 · Cited by 35
rAAV Manufacturing: The Challenges of Soft Sensing during Upstream Processing
Iglesias, C. F., Ristovski, M., Bolić, M., & Čuperlović‐Culf, M. (2023) · Bioengineering · doi:10.3390/bioengineering10020229 · Cited by 24
“Additionally, the setup of a spectroscopic system is expensive in terms of both financial outlay and calibration work [123].”
Chiappini, F. A., Teglia, C. M., Forno, Á. G., & Goicoechea, H. C. (2019) · Talanta · doi:10.1016/j.talanta.2019.120664 · Cited by 21
Ladner, T., Beckers, M., Hitzmann, B., & Büchs, J. (2016) · Biotechnology Journal · doi:10.1002/biot.201600515 · Cited by 20
“Multi-wavelength (2D) fluorescence spectroscopy is often mentioned as a potential measurement technique for online monitoring of cultures in the pharmaceutical and food industry [16, 20, 21].”
BackgroundMethodSelf-citationAhmad, M. H., Nache, M., Waffenschmidt, S., & Hitzmann, B. (2016) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2016.03.006 · Cited by 19
Self-citationAssawajaruwan, S., Reinalter, J., & Hitzmann, B. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9823-2 · Cited by 19
Self-citationMishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“These tables offer a structured overview of the advantages and limitations of each technique, facilitating an informed choice for practical implementation in biopharmaceutical and industrial bioprocesses [21,23].”
Ahmad, M. H., Nache, M., & Hitzmann, B. (2016) · Food Control · doi:10.1016/j.foodcont.2016.08.028 · Cited by 18
Self-citationChen, X., Hu, R., Hu, L., Huang, Y., Shi, W., Wei, Q., & Li, Z. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00837 · Cited by 19
“, 2020), and multi-wavelength fluorimetry (Faassen and Hitzmann, 2015; Rowland-Jones et al., 2017).”
Characterization of bacterial fluorescence: insight into rapid detection of bacteria in water
Mao, Y., Chen, X., Chen, Z., Chen, G.-Q., Lu, Y., Wu, Y.-H., & Hu, H.-Y. (2021) · Journal of Water Reuse and Desalination · doi:10.2166/wrd.2021.040 · Cited by 18
Głowacz, K., Skorupska, S., Grabowska‐Jadach, I., & Ciosek, P. (2022) · RSC Advances · doi:10.1039/d1ra09021f · Cited by 17
Boosted structured additive regression for Escherichia coli fed‐batch fermentation modeling
Melcher, M., Scharl, T., Luchner, M., Striedner, G., & Leisch, F. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.26073 · Cited by 16
“The successful application of the latter technique is frequently reported in the literature (€ Odman et al., 2009; Amigo et al., 2008; Clementschitsch et al., 2005; Faassen and Hitzmann, 2015; Hagedorn et al., 2003; Skibsted et al., 2001).”
MethodSuhandy, D., Yulia, M., Widodo, S., Naito, H., & Riza, D. F. A. (2025) · Food Chemistry · doi:10.1016/j.foodchem.2025.143791 · Cited by 17
An Ensemble Successive Project Algorithm for Liquor Detection Using Near Infrared Sensor
Qu, F., Ren, D., Wang, J., Zhang, Z., Lu, N., & Meng, L. (2016) · Sensors · doi:10.3390/s16010089 · Cited by 15
“The spectra retrieved from the near infrared (NIR) sensors have the potential to extract chemical information about the composition of a sample [8,9].”
Backgroundde Paulo, E. H., Magalhães, G. B., Moreira, M. P. B., Nascimento, M. H. C., Heringer, O. A., Filgueiras, P. R., & Ferrão, M. F. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.109804 · Cited by 15
Zalai, D., Kopp, J., Kozma, B., Küchler, M., Herwig, C., & Kager, J. (2020) · Drug Discovery Today Technologies · doi:10.1016/j.ddtec.2021.04.001 · Cited by 18
Supervision of Food Manufacturing Processes Using Optical Process Analyzers – An Overview
Zettel, V., Ahmad, M. H., Beltramo, T., Hermannseder, B., Hitzemann, A., Nache, M., Paquet‐Durand, O., Schöck, T., Hecker, F. T., & Hitzmann, B. (2016) · ChemBioEng Reviews · doi:10.1002/cben.201600013 · Cited by 16
Self-citationPaquet‐Durand, O., Assawarajuwan, S., & Hitzmann, B. (2017) · Engineering in Life Sciences · doi:10.1002/elsc.201700044 · Cited by 14
“Therefore, fluorescence spectroscopy has become one of the methods of choice for easy to implement bioprocess monitoring systems [4].”
MethodSelf-citationBrunner, M., Brosig, P., Losing, M., Kunzelmann, M., Calvet, A., Stiefel, F., Bechmann, J., Unsoeld, A., & Schaub, J. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201900050 · Cited by 15
Azcarate, S. M., Teglia, C. M., Karp, F., Camiña, J. M., & Goicoechea, H. C. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.03.036 · Cited by 13
Brehl, C., Brass, H. U. C., Lüchtrath, C., Böckmann, L., Ihling, N., Claßen, T., Pietruszka, J., & Büchs, J. (2022) · Biotechnology Progress · doi:10.1002/btpr.3245 · Cited by 12
Alemneh, S. T., Emire, S. A., Jekle, M., Paquet‐Durand, O., von Wrochem, A., & Hitzmann, B. (2022) · Foods · doi:10.3390/foods11081171 · Cited by 13
Self-citationFeedback control based on NADH fluorescence intensity for Saccharomyces cerevisiae cultivations
Assawajaruwan, S., Kuon, F., Funke, M., & Hitzmann, B. (2018) · Bioresources and Bioprocessing · doi:10.1186/s40643-018-0210-z · Cited by 14
“2015; Faassen and Hitzmann 2015).”
Self-citationNouchikian, L., Roque, C., Song, J. Y., Rahman, N., & Ausar, S. F. (2018) · Vaccine · doi:10.1016/j.vaccine.2018.08.005 · Cited by 12
Sensors for Disposable Bioreactor Systems
Steinwedel, T., Dahlmann, K., Solle, D., Scheper, T. H., Reardon, K. F., & Lammers, F. (2019) · Wiley eBooks · doi:10.1002/9781119477891.ch6 · Cited by 14
Assawajaruwan, S., Eckard, P., & Hitzmann, B. (2017) · Process Biochemistry · doi:10.1016/j.procbio.2017.05.007 · Cited by 12
Self-citationSchlaugat, J., Patzer, K., Hentrop, T., Solle, D., Pepelanova, I., Schröder, U., & Scheper, T. H. (2020) · Engineering in Life Sciences · doi:10.1002/elsc.201900140 · Cited by 13
“Depending on the metabolite to be analyzed, different wavelengths are selected for excitation and emission [11].”
BackgroundAvoiding misleading predictions in fluorescence-based soft sensors using autoencoders
Ranzan, L., Trierweiler, L. F., Hitzmann, B., & Trierweiler, J. O. (2022) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2022.104527 · Cited by 10
Self-citationReliable online measurement of population dynamics for filamentous co‐cultures
Palacio‐Barrera, A. M., Schlembach, I., Finger, M., Büchs, J., & Rosenbaum, M. A. (2022) · Microbial Biotechnology · doi:10.1111/1751-7915.14129 · Cited by 14
“…originating from biogenic fluorophores (tryptophan, NADH and flavins) (Pöhlker et al., 2012) has been utilized for the estimation of biomass growth and metabolic activity in axenic cultures (Faassen & Hitzmann, 2015; König et al., 2018; Schlembach et al., 2021; Surribas et al., 2006).”
MethodBerg, C., Ihling, N., Finger, M., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2022) · Bioengineering · doi:10.3390/bioengineering9090438 · Cited by 10
“The implementations of PLS regression used for the online monitoring and control of bioprocesses in stirred tank reactors are numerous and have extensively been reviewed in the literature [26,39,40].”
MethodSelf-citationPresent Status of Automation for Industrial Bioprocesses
Hausmann, R., Henkel, M., Hecker, F. T., & Hitzmann, B. (2016) · Elsevier eBooks · doi:10.1016/b978-0-444-63663-8.00025-2 · Cited by 10
Self-citationImplementation of a fluorescence based PAT control for fouling of protein A chromatography resin
Pathak, M., & Rathore, A. S. (2017) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.5358 · Cited by 10
2025 photonics for agrifood roadmap: towards a sustainable and healthier planet
Smeesters, L., Venturini, F., Paulus, S., Mahlein, A., Perpetuini, D., Cardone, D., Merla, A., Gac, B., Perrin, S., Trégoat, D., et al. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/adbea9 · Cited by 16
Zabadaj, M., Chreptowicz, K., Mierzejewska, J., & Ciosek, P. (2016) · Biotechnology Progress · doi:10.1002/btpr.2381 · Cited by 12
“NIR spectroscopy prevails for bioprocess fingerprinting.(28) However, both methods are not as sensitive compared to fluorescence spectroscopy.”
BackgroundGłowacz, K., Skorupska, S., Grabowska‐Jadach, I., Bro, R., & Ciosek, P. (2023) · ACS Omega · doi:10.1021/acsomega.2c05383 · Cited by 9
“12 The result of such a measurement can be presented in the form of a 2D fluorescence landscape (excitation − emission matrix, EEM), regarded as a characteristic and unique signature of the tested sample (“fingerprint”), which encodes information on the fluorescent substances present in it, in…”
He, J.-R., Wei, J.-W., Chen, S., Li, N., Zhong, X.-D., & Li, Y. (2022) · Sensors · doi:10.3390/s22249979 · Cited by 10
Chopda, V., Pathak, M., Batra, J., Gomes, J., & Rathore, A. S. (2016) · Engineering in Life Sciences · doi:10.1002/elsc.201600155 · Cited by 9
“In addition, the HPLC analysis time required typically varies from 30 min to several hours [18].”
BackgroundMonago‐Maraña, O., Manzano, J., de la Peña, A. M., & Durán‐Merás, I. (2020) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2020.103980 · Cited by 8
Boateng, B. O., Elcoroaristizabal, S., & Ryder, A. G. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27694 · Cited by 8
“…and S4, SI): R1 (λex = 240–300 nm) mostly related to emission from aromatic amino acids (B. Y. Li et al., 2012); R2 (λex = 320–360 nm) corresponding to larger fluorophores such as vitamins (Faassen & Hitzmann, 2015), and R3 (λex > 360 nm) corresponding to co‐factors and flavins (Graf et al., 2019).”
BackgroundSpectroscopic analysis of chia seeds
Mburu, M. W., Paquet‐Durand, O., Hitzmann, B., & Zettel, V. (2021) · Scientific Reports · doi:10.1038/s41598-021-88545-5 · Cited by 12
Self-citationDevelopment and characterisation of a new fluorescence sensor for online monitoring of bioprocesses
König, J. C., Steinwedel, T., Solle, D., Lindner, P., de Vries, I., Hentrop, T., Findeis, M., John, G. T., Scheper, T. H., & Beutel, S. (2018) · Journal of sensors and sensor systems · doi:10.5194/jsss-7-461-2018 · Cited by 9
Reynolds-Brandão, P., Quintas-Nunes, F., Bertrand, C., Martins, R. M., Crespo, M. T. B., Galinha, C. F., & Nascimento, F. X. (2024) · Bioresource Technology · doi:10.1016/j.biortech.2024.131988 · Cited by 8
Paquet‐Durand, O., Ladner, T., Büchs, J., & Hitzmann, B. (2017) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2017.10.003 · Cited by 7
Self-citationMonitoring the Recombinant Adeno-Associated Virus Production using Extended Kalman Filter
Iglesias, C. F., Xu, X., Mehta, V., Akassou, M., Venereo-Sánchez, A., Belacel, N., Kamen, A., & Bolić, M. (2022) · Processes · doi:10.3390/pr10112180 · Cited by 8
“Moreover, the setup of a spectroscopy system is costly in terms of the investment and calibration effort [13].”
BackgroundAli, H., Anwar, S., & Khan, R. A. (2024) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2024.124877 · Cited by 6
Chiappini, F. A., Azcarate, S. M., Alcaráz, M. R., Forno, Á. G., & Goicoechea, H. C. (2021) · Biotechnology Progress · doi:10.1002/btpr.3173 · Cited by 6
“(referred as R1) and comprises the signal originated from aromatic amino acids, whereas in the other region (R2), the signal is attributed to the presence of other fluorophores, such as vitamins and co-factors, which are less abundant.(22) MCR-ALS modeling allowed a qualitative characterization of each System in terms…”
BackgroundMethodInfluentialVelázquez-Martí, B., Pérez, S., Gaibor‐Chávez, J., & Wilcaso, P. (2016) · Energies · doi:10.3390/en9050319 · Cited by 7
“[12,13].”
Pen, U.-Y., Nunn, C. J., & Goyal, S. (2021) · ACS Synthetic Biology · doi:10.1021/acssynbio.0c00574 · Cited by 9
Ergot alkaloid control in biotechnological processes and pharmaceuticals (a mini review)
Volnin, A., Parshikov, A., Tsybulko, N. S., Мизина, П. Г., & Sidelnikov, N. I. (2024) · Frontiers in Toxicology · doi:10.3389/ftox.2024.1463758 · Cited by 5
Ranade, D. S., Jena, R., Sancheti, S., Deore, V., Dogar, V., & Gairola, S. (2021) · Vaccine · doi:10.1016/j.vaccine.2021.12.019 · Cited by 5
Karakach, T. K., Dachon, A., Choi, J. J., Míguez, C. B., Masson, L., & Tartakovsky, B. (2018) · Biotechnology Progress · doi:10.1002/btpr.2761 · Cited by 9
“This choice allowed to observe fluorescence emission peaks corresponding to NAD(P)H, pyrodoxin, riboflavin, and extracellular proteins.(3) Importantly, the MCR algorithm used the complete emission spectra for process trend diagnostics, as opposed to analyzing few selected peaks.”
BackgroundMethodCaputi, A. F., Squeo, G., Sikorska, E., Silletti, R., Noviello, M., Pasqualone, A., Summo, C., & Caponio, F. (2024) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.13435 · Cited by 4
Boateng, B. O., & Ryder, A. G. (2024) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2024.10.002 · Cited by 4
Bioprocess monitoring by biosensor-based technologies
Göker, M., Kurbanoğlu, S., Huri, P. Y., Sezgintürk, M. K., & Özkan, S. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818592-6.00010-4 · Cited by 8
Sampling, preservation, and growth monitoring of filamentous fungi
Harirchi, S., Rousta, N., Varjani, S., & Taherzadeh, M. J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91872-5.00014-4 · Cited by 4
In-line monitoring of Bordetella pertussis cultivation using fluorescence spectroscopy
Mishra, A., Tamer, M. I., & Budman, H. M. (2023) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-023-02857-6 · Cited by 3
“For example, [14] used NIR in situ combined with metabolic flux analysis model with PLS as a multivariate analysis method for real time monitoring of biomass and glycerol in Pichia pastoris culture.”
BackgroundInfluentialYeboah, M. K., Asiedu, N. Y., & Addo, A. (2026) · Sensors · doi:10.3390/s26123948 · Cited by 3
“More recent work has further highlighted the importance of soft-sensor generalizability, sensor recalibration, biomass monitoring, spectroscopic data streams, and joint state–parameter estimation for reliable model-assisted monitoring [12–14 , 16–”
Spectroscopic-Based Prediction of Milk Foam Properties for Barista Applications
Brettschneider, K. C., Zettel, V., Vasafi, P. S., Hummel, D., Hinrichs, J., & Hitzmann, B. (2022) · Food and Bioprocess Technology · doi:10.1007/s11947-022-02822-3 · Cited by 3
“One dominant peak as protein peak, and two small peaks for the identification of the vitamins B2 and B6 (Faassen & Hitzmann, 2015) can be identified.”
BackgroundSelf-citationBerg, C., Herbst, L., Gremm, L., Ihling, N., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2023) · Journal of Biological Engineering · doi:10.1186/s13036-023-00332-0 · Cited by 4
Self-citationIvashchenko, O., Jędrzak, A., Lys, A., Załęski, K., Różańska, S., Różański, J., Coy, E. L., & Iatsunskyi, I. (2024) · Applied Surface Science · doi:10.1016/j.apsusc.2024.160916 · Cited by 3
Optische Prozessanalysatoren für die Lebensmittelindustrie
Zettel, V., Ahmad, M. H., Hitzemann, A., Nache, M., Paquet‐Durand, O., Schöck, T., Hecker, F. T., & Hitzmann, B. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500097 · Cited by 3
Self-citationProcessing Fluorescence Spectra for Pollutants Detection Systems in Inland Waters
Orobón, F. J. A., Prieto‐Castrillo, F., Núñez, N., & González‐Posadas, V. (2020) · Sensors · doi:10.3390/s20113102 · Cited by 3
Application of Fluorescence Spectroscopy for Contaminants Determination in Food
Bartolić, D., & Radotić, K. (2025) · Springer eBooks · doi:10.1007/978-3-031-89681-1_15 · Cited by 2
da Silva, J. D., Dias, V. A. T., Rabello, J. P., Barrance, F. A. C., Teruya, M. M., Taciro, M. K., Jacobus, A. P., Leme, J., Bernardino, T. C., Jorge, S. A. C., et al. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126663 · Cited by 2
Pérez, P. A. L., Aguilar‐López, R., & Femat, R. (2020) · Wiley eBooks · doi:10.1002/9781119296317.ch1 · Cited by 3
Berg, C., Busch, S., Alawiyah, M. D., Finger, M., Ihling, N., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28474 · Cited by 1
Self-citation
Metadata
- Authors
- Faassen, S., & Hitzmann, B.
- Affiliations
- University of Hohenheim (DE)
- Corresponding author
- Hitzmann, Bernd
- ORCID
- Hitzmann, Bernd
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-04-30
- Volume
- 15
- Issue
- 5
- Pages
- 10271-10291
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4481931
- OpenAlex
- W2091004417
- Cited by
- 120
- References
- 90
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 8 · 2023: 8 · 2022: 15 · 2021: 14 · 2020: 13 · 2019: 13 · 2018: 7 · 2017: 10 · 2016: 17
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- fluorescence spectroscopy, bioprocess monitoring, chemometric models, online sensors, partial least squares, microbial cultivation, process control
- MeSH terms
- Biotechnology, Spectrometry, Fluorescence, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.