Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Quantitative assessment of parkinsonian tremor based on inertial sensors can provide reliable feedback on the effect of medication. In this regard, the features of parkinsonian tremor and its unique properties such as motor fluctuations and dyskinesia are taken into account. Least-square-estimation models are used to assess the severities of rest, postural, and action tremors. In addition, a time-frequency signal analysis algorithm for tremor state detection was also included in the tremor assessment method. This inertial sensor-based method was verified through comparison with an electromagnetic motion tracking system. Seven Parkinson’s disease (PD) patients were tested using this tremor assessment system. The measured tremor amplitudes correlated well with the judgments of a neurologist (r = 0.98). The systematic analysis of sensor-based tremor quantification and the corresponding experiments could be of great help in monitoring the severity of parkinsonian tremor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“The action tremor (kinetic tremor) happens when a voluntary contraction of a muscle follows a certain action—for example, holding a cup [6].”
BackgroundLouis, E. D., & Ferreira, J. J. (2010) · Movement Disorders · doi:10.1002/mds.22838 · Cited by 906
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“The occurrence and amplitude of parkinsonian tremor are influenced by such effects [10,11].”
BackgroundSalarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Dynamics of tremor-related oscillations in the human globus pallidus: a single case study
Hurtado, J. M., Gray, C. M., Tamas, L. B., & Sigvardt, K. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.4.1674 · Cited by 246
Time-frequency analysis of tremors
O'Suilleabhain, P. (1998) · Brain · doi:10.1093/brain/121.11.2127 · Cited by 157
Pathological tremors: deterministic chaos or nonlinear stochastic oscillators?
Timmer, J., Häussler, S., Lauk, M., & Lücking, C.-H. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166494 · Cited by 130
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117 · cited 1×
“Tremor Quantification has been performed by signal processing methods such as time-domain analysis, time-frequency analysis, spectral analysis, and nonlinear analysis [31,32].”
MethodCharacteristics of hand tremor time series
Timmer, J., Gantert, C., Deuschl, G., & Honerkamp, J. (1993) · Biological Cybernetics · doi:10.1007/bf00202568 · Cited by 112
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83 · cited 2×
“The relation between the peak power of IMU signals and the consistency of IMU signals in PD patients should be studied [43,44].”
Background
Cited by
Steven Eyobu, O., & Han, D. S. (2018) · Sensors · doi:10.3390/s18092892 · Cited by 259
“In [24], a quantitative assessment of Parkinson’s tremor is conducted using least-square-estimation models.”
BackgroundMethodde Faria, S. M., de Morais Fabrício, D., Tumas, V., Castro, P. C., Ponti, M. A., Hallak, J. E., Zuardi, A. W., Crippa, J. A. S., & Chagas, M. H. N. (2020) · Journal of Psychopharmacology · doi:10.1177/0269881119895536 · Cited by 140
Kim, H. B., Lee, W. W., Kim, A., Lee, H. J., Park, H. Y., Jeon, H. S., Kim, S. K., Jeon, B., & Park, K. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.02.007 · Cited by 124
Using Portable Transducers to Measure Tremor Severity
Elble, R. J., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.320 · Cited by 95
Papadopoulos, A., Kyritsis, K., Klingelhoefer, L., Bostanjopoulou, S., Chaudhuri, K. R., & Delopoulos, A. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2961748 · Cited by 79
“In a similar spirit, [10] [11] and [12] make use of stand-alone accelerometer and gyroscope sensors to quantify tremor severity,”
BackgroundRabelo, A. G., Neves, L. P., Paixão, A. P. S., Oliveira, F. H. M., de Souza, L. A. P. S., Vieira, M. F., Pereira, A. A., & Andrade, A. O. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1908-3 · Cited by 46
Using Portable Transducers to Measure Tremor Severity
Elble, R., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.7916/d8dr2vcc · Cited by 43
High-accuracy automatic classification of Parkinsonian tremor severity using machine learning method
Jeon, H., Lee, W., Park, H., Lee, H. J., Kim, S. K., Kim, H. B., Jeon, B., & Park, K. S. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa8e1f · Cited by 43
“Finally, for automatic scoring of PD-patient tremors, only a regression model has been applied (Giuffrida et al 2009, Dai 2015, Pan et al 2015). to the best of our knowledge, machine learning approaches have not yet been applied for automatic Parkinsonian-tremor scoring.”
BackgroundMethodResultA Wearable System for Attenuating Essential Tremor Based on Peripheral Nerve Stimulation
Kim, J., Wichmann, T., Inan, O. T., & Deweerth, S. P. (2020) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2020.2985058 · Cited by 33
“fa = 4Hz, fb = 12 Hz; [33] (2)”
BackgroundMethod
Metadata
- Authors
- Dai, H., Zhang, P., & Lueth, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-09-29
- Volume
- 15
- Issue
- 10
- Pages
- 25055-25071
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2104033295
- Cited by
- 159
- References
- 11
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.